background image

CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION REQUIREMENTS IN

THE AREA.

READ THIS ENTIRE GUIDE BEFORE INSTALLATION AND USE OF THIS WOOD INSERT. FAILURE TO FOLLOW THESE

INSTRUCTIONS COULD RESULT IN PROPERTY DAMAGE, BODILY INJURY OR EVEN DEATH.

READ AND KEEP THIS GUIDE FOR REFERENCE

Printed in Canada

2022-09-19

Wood Insert 

Owner’s Manual

Part 1 of 2

SAFETY NOTIFICATIONS 

AND GENERAL INFORMATION 

46235A

Содержание CB00027

Страница 1: ...HIS ENTIRE GUIDE BEFORE INSTALLATION AND USE OF THIS WOOD INSERT FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN PROPERTY DAMAGE BODILY INJURY OR EVEN DEATH READ AND KEEP THIS GUIDE FOR REFERENCE Printed in Canada 2022 09 19 Wood Insert Owner s Manual Part 1 of 2 SAFETY NOTIFICATIONS AND GENERAL INFORMATION 46235A ...

Страница 2: ......

Страница 3: ... APC Association des Professionnels du Chauffage Contact local building or fire officials about restrictions and installation inspection requirements in the area A building permit might be required for the installation of this insert and the chimney that it is connected to It is also recommended to inform your home insurance company Please read this entire guide before installing and using this in...

Страница 4: ......

Страница 5: ...on Cycles 13 3 5 Rekindling a Fire 14 3 6 Removing Ashes 14 3 7 Air Intake Control 15 3 8 Fire Types 15 4 Maintenance 17 4 1 Wood Insert 17 4 2 Glass Door 17 5 Operating the Insert 18 5 1 Blower 18 5 2 Fire Screen 19 5 3 Exhaust System 19 6 Masonry Fireplace Requirements 20 6 1 Fireplace and Chimney Condition 20 6 2 Chimney Caps 21 6 3 Adjacent Combustibles 21 6 4 Masonry Fireplace Throat Damper 2...

Страница 6: ...TOR OIL KEROSENE CHARCOAL LIGHTER FLUID OR SIMILAR LIQUIDS OR AEROSOLS TO START A FIRE IN THIS INSERT KEEP ALL SUCH LIQUIDS OR AEROSOLS WELL AWAY FROM THE INSERT WHILE IT IS IN USE Do not store fuel within heater minimum installation clearances Burn only seasoned natural firewood This wood heater needs periodic inspection and repair for proper operation It is against federal regulations to operate...

Страница 7: ...ons but is not intended for installation in a bedroom In Canada the CSA B365 Installation Code for Solid Fuel Burning Appliances and Equipment and the CSA C22 1 Canadian National Electrical Code are to be followed in the absence of local code requirements In the USA the ANSI NFPA 211 Standard for Chimneys Fireplaces Vents and Solid Fuel Burning Appliances and the ANSI NFPA 70 National Electrical C...

Страница 8: ...e necessary many years in the future almost the entire insert can be recycled into new products thus eliminating the need to mine new materials The paint coating on the insert is very thin Its VOC content Volatile Organic Compounds is very low VOCs can be responsible for smog so all the paint used during the manufacturing process meets the latest air quality requirements regarding VOC reduction or...

Страница 9: ...from is less important than its moisture content The main difference in firewood from various tree species is the density of the wood Hardwoods are denser than softwoods Homeowners with access to both hardwood and softwood use both types for different purposes Softer woods make good fuel for mild weather in spring and fall because they light quickly and produce less heat Softwoods are not as dense...

Страница 10: ...inually burning green or unseasoned wood produces more creosote and involves lack of heat and dirty glass door Firewood with a moisture content between 15 and 20 will allow the insert to produce its highest possible efficiency Here are some facts to consider in estimating drying time Firewood bought from a dealer is rarely dry enough to burn so it is advisable to buy the wood in spring and dry it ...

Страница 11: ...ar until one or two very hot fires have been burned 3 2 Lighting Fires Each person heating with wood develops its own favorite way to light fires Regardless of the method chosen the goal should be to have a hot fire burning quickly A fire that ignites fast produces less smoke and deposits less creosote in the chimney Here are three popular and effective ways to ignite wood fires 3 2 1 Conventional...

Страница 12: ...mmercial fire starters can be used instead of a newspaper Some of these starters are made of sawdust and wax and others are made of specialized flammable solid chemicals Always follow the package directions when using Gel starters can also be used but only to light a fire in a cold combustion chamber without hot embers inside 3 3 Zone Heating This insert is a space heater which means it is intende...

Страница 13: ...ning cycle This increasing and decreasing temperature can be matched with the household routines For example the temperature in the area can be cooler when the household is active and it can be warmer when it is inactive Wood burns best in cycles A cycle starts when a new load of wood is ignited by hot coals and ends when that load has been consumed down to a bed of charcoal about the same size as...

Страница 14: ...sant when the room temperature is cool but can be unpleasant when the room is already warm Therefore it is best to let each load of wood burn completely so that the room cools down before putting a load of wood back on 3 6 Removing Ashes Ash should be removed from the firebox every two to three days of full time heating Ash should not accumulate excessively in the firebox since it will affect the ...

Страница 15: ... Insert Installation and Operation Manual for a specific overview of the air control of your appliance Figure 1 Air Intake Control 3 8 Fire Types Using the air intake control is not the only way to match the insert heat output to the desired temperature in the house A house will need far less heating in October than in January to maintain a comfortable temperature Filling the firebox full in fall ...

Страница 16: ...of the burn cycle and the second half is the coal bed phase during which there is little or no flame The burn time expected from an insert including both phases will vary depending on a number of things such as firebox size the amount of wood loaded the species of wood the wood moisture content the size of the space to be heated the climate zone where the house is and the time of the year The tabl...

Страница 17: ...burn cycles 4 1 Wood Insert 4 1 1 Cleaning and Painting Painted and plated surfaces can be wiped down with a soft damp cloth If the paint is scratched or damaged it is possible to repaint the insert with a heat resistant paint see Exploded diagram and parts list in the Wood Insert Installation and Operation Manual Do not clean or paint the insert when it is hot Before painting the surface should b...

Страница 18: ...istent with operating instructions in this guide Before using the insert the following steps should be completed you will find the procedures installation in the Wood Insert Installation and Operation Manual Handle installation Installation of bricks in the product Installation of ash shelf and blower Faceplate installation The following step is optional Air inlet installation 5 1 Blower A blower ...

Страница 19: ...FIRE SCREEN INCREASES POSSIBILITIES OF GENERATING CARBON MONOXIDE CARBON MONOXIDE IS AN ODOURLESS GAS THAT IS HIGHLY TOXIC WHICH CAN CAUSE DEATH AT HIGH CONCENTRATION IN AIR 5 3 Exhaust System Wood smoke can condense inside the chimney forming a inflammable deposit called creosote If creosote builds up in the system it can ignite when a hot fire is burned in the insert A very hot fire can progress...

Страница 20: ...e insert door and the air intake control 2 Alert the occupants of the house of the possible danger 3 If you require assistance alert the fire department 4 If possible use a dry chemical fire extinguisher baking soda or sand to control the fire Do not use water as it may cause a dangerous steam explosion Do not use the appliance again until the insert and its chimney have been inspected by a qualif...

Страница 21: ... removed entirely If it is removed from the masonry hearth the notice plate 27009 must be installed in a visible place inside the masonry hearth The plate can be found in the owner s manual kit 7 The Venting System 7 1 General The venting system made of the chimney and the liner inside the chimney acts as the engine that drives the wood heating system Even the best insert will not function safely ...

Страница 22: ...is greater than 20 feet 7 4 Chimney Liner Installation The use of a chimney liner rigid or flexible is recommended to ensure the best performance To ensure an optimal draft it is also strongly recommend adding a minimum of 12Ǝ rigid liner between the top of the masonry chimney and the rain cap In all cases liners should be installed in accordance with the liner manufacturer s instructions includin...

Страница 23: ...arter adapter to the flue outlet install three brackets with the three screws all provided in the user manuals kit on top of the insert The long end of the brackets must be attached to the insert Insert the chimney liner into the flue collar of the unit and secure the liner to the brackets with three self tapping screws not included Figure 7 Securing the brackets The dealer may offer a liner faste...

Страница 24: ...it tends to rise This creates a slight pressure difference in the house Called stack effect it produces a slightly negative pressure in the lower part of the house compared to the outside and a slightly positive pressure zone in the high part of the house If there is no fire burning in a heater connected to a chimney that is shorter than the warm space inside the house the slight negative pressure...

Страница 25: ...ide a small amount of air needed by the insert The only case in which the wood insert may not have adequate access to combustion air is if the operation of a powerful exhaust device such as a kitchen range exhaust causes the pressure in the house to become negative relative to outdoors 8JOEXBSE 3FDPNNFOEFE 0VUTJEF JS OUBLF PO XJOEXBSE TJEF FFXBSE 05 SFDPNNFOEFE 0VUTJEF JS OUBLF PO MFFXBSE TJEF VMU...

Страница 26: ...ional com This document is available for free download on the manufacturer s website It is a copyrighted document Resale is strictly prohibited The manufacturer may update this document from time to time and cannot be responsible for problems injuries or damages arising out of the use of information contained in any document obtained from unauthorized sources ...

Страница 27: ...ULD RESULT IN PROPERTY DAMAGE BODILY INJURY OR EVEN DEATH READ AND KEEP THIS MANUAL FOR REFERENCE US Environmental Protection Agency phase II certified wood insert compliant with 2020 cord wood standard Printed in Canada 2022 09 14 CW2100 INSERT CB00027 Model 46294_IA ENGLISH Safety tested according to ULC S628 UL 1482 and UL 737 by an accredited laboratory Wood Insert Owner s Manual Part 2 of 2 I...

Страница 28: ...s the warranty period If it can not be provided the warranty period will be determined by the date of manufacture of the product It is also highly recommended to register the warranty online at https www century heating com ca en warranty warranty registration Registering the warranty will help to quickly find the information needed on the unit Dealer Installer Phone Number Serial Number ...

Страница 29: ...ENGLISH CERTIFICATION PLATE ...

Страница 30: ...Page 4 Product Specification Manual CW2100 ENGLISH ...

Страница 31: ...r Product and Replacing Parts 15 3 1 Replacement and Adjustment 15 3 2 Mandatory Installation 17 3 3 Connecting the Blower With a BX Wire 17 3 4 Changing the Side of the Blower Power Cord 20 3 5 Blower Removal 23 3 6 Removable Air Control Handle 24 3 7 Faceplate Installation 25 3 8 Faceplate Decorative Panel Installation Removal 26 3 9 Optional Fresh Air Intake Kit Installation 27 3 10 Optional Fi...

Страница 32: ...he designated area in case of a power failure 2 The overall firebox calculation is an approximation and is not intended to be used for loading This volume includes a buffer zone to allow an easier fuel insertion prevent ash spillage and allow the air wash to work properly 3 The maximum heat output dry cordwood is based on a loading density varying between 15 lb ft3 and 20 lb ft3 Other performances ...

Страница 33: ... ends of the logs visible East west sides of the logs visible 13 Mobile homes Canada or manufactured homes USA The US Department of Housing and Urban Development describes manufactured homes better known as mobile homes as follows buildings built on fixed wheels and those transported on temporary wheels axles and set on a permanent foundation In Canada a mobile home is a dwelling for which the manu...

Страница 34: ...TERNATIONAL INC TOUS DROITS RESERVÉS ALL RIGHTS RESERVED 17 432mm 20 1 8 513mm 17 3 8 442mm 8 1 8 207mm 5 1 8 131mm 10 5 8 268mm 25 635mm 10 1 2 265mm 18 3 4 476mm 2 1 4 58mm SANS FAÇADE DÉCORATIVE WITHOUT DECORATIVE FACEPLATE 26 1 4 666mm 42 1068mm 21 1 8 537mm 15 1 2 395mm 21 7 8 555mm 27 7 8 708mm 6 153mm ...

Страница 35: ...0 ENGLISH CW2100 CB00027 CHAMBRE À COMBUSTION COMBUSTION CHAMBER 2022 FABRICANT DE POÊLES INTERNATIONAL INC TOUS DROITS RESERVÉS ALL RIGHTS RESERVED 12 3 8 315mm 8 3 4 224mm 3 16 5mm 3 16 5mm 18 1 4 462mm 7 7 8 200mm 16 3 8 416mm 19 1 4 490mm ...

Страница 36: ...mpletely burnt out and it is possible to break them into pieces level the coal bed and put four logs in the firebox in an east west orientation Place a medium log about 4 x4 in front of the combustion chamber and the biggest log about 5 x5 in the back of the combustion chamber Place the last two medium pieces on top of the two others in an orientation that points to the right Do not leave space be...

Страница 37: ...ning and Clearances to Combustibles Figure 1 Hearth opening and clearances to combustibles MINIMUM CLEARANCES F 16 406 mm I 34 864 mm Q 72 183 cm MAXIMUM THICKNESS O 3 76 mm P 1 5 38 mm R 12 305 mm MINIMUM MASONRY OPENING J 19 483 mm K15 25 635 mm L 15 394 mm FACADE CLEARANCES From combustible side surround 1 25 mm From combustible top surround 1 25 mm 15 If a fresh air intake is required it is re...

Страница 38: ...ection Calculation of this section D B G where G A C HEARTH SLAB NON COMBUSTIBLE MATERIAL FLOOR PROTECTOR NON COMBUSTIBLE MATERIAL B C D E F A G HEARTH SLAB NON COMBUSTIBLE MATERIAL FLOOR PROTECTOR NON COMBUSTIBLE MATERIAL B C D E F A G Figure 3 Additional Floor Protection Raised Installation Figure 4 Additional Floor Protection Not Raised Installation Table 2 Data for Floor Protection Calculation...

Страница 39: ...ments the combination is acceptable R values of some selected materials are shown below Table 3 Thermal Characteristics of Common Floor Protection Materials17 MATERIAL CONDUCTIVITY K PER INCH RESISTANCE R PER INCH THICKNESS Micore 160 0 39 2 54 Micore 300 0 49 2 06 Durock 1 92 0 52 Hardibacker 1 95 0 51 Hardibacker 500 2 3 0 44 Wonderboard 3 23 0 31 Cement mortar 5 00 0 2 Common brick 5 00 0 2 Fac...

Страница 40: ... than the required 1 00 and is therefore acceptable In the case of a known K and thickness of alternative materials to be used in combination convert all K values to R by dividing the thickness of each material by its K value Add R values of the proposed materials as shown in the previous example Exemple K value 0 75 Thickness 1 R value Thickness K 1 0 75 1 33 ...

Страница 41: ...y anywhere either adjust the door or replace the gasket 3 1 2 Gasket It is important to replace the gasket with another having the same diameter and density to maintain a good seal 1 Remove the door and place it face down on something soft like a cushion of rags or a piece of carpet 2 Remove the old gasket from the door Use a screwdriver to scrape the old gasket adhesive from the door gasket groov...

Страница 42: ...hinges of the door using a 3 32 Allen key to free the adjustable hinge rods Using a flat screwdriver turn the adjustable hinge rods in the direction shown to adjust the doors Tighten all door hinge pressure screws when they are at the desired positions Configurations 1 2 3 4 5 6 show in which direction these act on the adjustment of the door 5 6 4 2 A B 1 3 ...

Страница 43: ... 5 Empty the combustion chamber Figure 6 Remove brick supports 3 3 Connecting the Blower With a BX Wire 1 Remove the screws A to remove the plate B and gain access to the wires Save the screws for later 2 Disconnect the black C and white D wires 3 Remove the ground screw E to remove the green wire Save the screw for later A B E D C CAUTION RISK OF ELECTROCUTION All electrical connections should be...

Страница 44: ...of the black and white wires F that are in the box attached to the insert 5 Remove the piece of metal G from the plate B obstructing the hole to the left of the power cord H using pliers or a screwdriver Cut the power cord H on each side of the black clamp 1 2 13mm F F G H ...

Страница 45: ...h the connector I and install the sleeve J supplied with the manual kit on the BX wire 8 Join the black and white wires using marettes K not supplied and secure the ground wire with the screw E kept in step 3 9 Close the connection box by screwing in the plate B with the two screws A kept in step 1 and secure the BX wire by tightening the screw L of the connector I I A J K E L ...

Страница 46: ... L Then unscrew the three plastic grommets C located on the base of the fan Remove the wires from the grommets Keep the screws 2 Disconnect the white wire D and the black wire E follow the wires coming from the inside of the insert Remove the four screws F that hold the connection box G to the insert and gently pull it out until the white and black wires come out of the insert Keep the screws A B ...

Страница 47: ...plate H and screws I 4 Pass the white D and black E wires through the hole formed in the previous step by pulling them towards the front of the insert Then pass the wires through the grommet J located on the side at the front of the device 5 Screw the connection box G with the four screws F kept in step 2 H I G F J ...

Страница 48: ...o be able to connect them to their respective locations the black wire is connected to the rheostat and the white wire is connected to the blower An extension cable must be installed on the black wire to get to the rheostat extension supplied with the manual kit 8 Secure the excess wires using the three plastic grommets C removed in step 1 9 Reinstall the grille B with the screws A kept in step 1 ...

Страница 49: ... Specification Manual CW2100 ENGLISH 3 5 Blower Removal 1 Remove the two screws A on each side of the grille B to be able to remove it 2 Unscrew the two wing nuts C on each side of the fan A B C 3 Take out the fan D D ...

Страница 50: ...r Control Handle This insert comes with a removable handle for the primary air control A holder for the handle is supplied with the manual Here is an example of the holder installation CAUTION Do not leave the handle on the air control after use as it will get very hot ...

Страница 51: ...els on a flat and non abrasive surface Align the top panel holes A with the left and right panels B and C Secure together using the bolts D and nuts E provided 2 Install the grille on the assembled faceplate and bend the tabs using pliers 3 Hang the assembled faceplate on the insert A B C D E ...

Страница 52: ...ate decorative panel The latter is included with the insert and is already partially installed with two screws at each end Here are the steps to remove or keep it Faceplate decorative panel removal Remove the screws B at each end of the panel A to be able to remove it afterwards Faceplate decorative panel installation Screw the panel with 6 additional screws B A B B ...

Страница 53: ...in the user manual kit Install the fresh air intake adapter E with four screws F then secure the flexible pipe19 H not included to the adapter using one of the pipe clamps G Secure the other end of the pipe to the outside wall termination J using the other pipe clamp The outside wall termination must be installed outside of the home 15 The pipe must be HVAC type insulated and must comply with ULC ...

Страница 54: ... Screen Installation In the United States or in provinces with a particulate emissions limit e g US EPA the use of open door wood stoves with a rigid firescreen is prohibited 1 Open the door 2 Hold the fire screen by the two handles and bring it close to the door opening ...

Страница 55: ...t the fire screen rest on the bottom of the door opening 1 3 11 Air Tubes and Baffle Installation 1 Starting with the rear tube lean and insert the right end of the secondary air tube into the rear right channel hole Then lift and insert the left end of the tube into the rear left channel 2 3 Never leave the insert unattended while in use with the fire screen Do not use the blower with the fire sc...

Страница 56: ... in place by turning the tube as shown Make sure the notch reaches the end of the key way 3 Install the baffle 4 Repeat steps 1 and 2 for the two other tubes 5 To remove the tubes use the above steps in reverse order Note that secondary air tubes A can be replaced without removing the baffle board B and that all tubes are identical ...

Страница 57: ...A B A B ...

Страница 58: ...o remove the insert follow these instructions Remove the blower grille E and faceplate D by lifting it and then pulling on it Remove the blower C Remove the three screws securing the pipe connector A Unscrew the bolts securing the insert to the floor on each side of the unit B B A D E C ...

Страница 59: ...Page 33 Product Specification Manual CW2100 ENGLISH 3 13 Exploded Diagram and Parts List ...

Страница 60: ...SS GASKET 1 9 SE74847 CW2100 CENTURY FACEPLATE 1 10 PL74850 FACEPLATE GRILL 1 11 PL74849 RIGHT FACEPLATE 1 12 PL74847 TOP FACEPLATE 1 13 PL74848 LEFT FACEPLATE 1 14 SE46294 CB00027 INSTRUCTION MANUAL KIT 1 15 AC05959 METALLIC BLACK STOVE PAINT 342 g 12oz AEROSOL 1 16 SE74798 GLASS GASKET AND MOULDING KIT 1 17 SE74775 GLASS WITH GASKET 15 3 4 X 10 1 8 1 18 PL74798 GLASS RETAINER 2 19 60013 POWER CO...

Страница 61: ...according to the table below The manufacturer at its discretion may decide to repair or replace any part or unit after inspection and investigation of the defect The manufacturer may at its discretion fully discharge all obligations with respect to this warranty by refunding the wholesale price of any warranted but defective parts The manufacturer shall in no event be responsible for any uncommon ...

Страница 62: ...ernational com This document is available for free download on the manufacturer s website It is a copyrighted document Resale is strictly prohibited The manufacturer may update this document from time to time and cannot be responsible for problems injuries or damages arising out of the use of information contained in any document obtained from unauthorized sources ...

Отзывы: