Centurion LD200 Series Скачать руководство пользователя страница 1

1

High

-

0.01%

2

-

0.02%

3

-

0.05%

4

-

  0.1%

5

-

0.2%

6

-

0.5%

7

-

 

 

 

1%

8

Low

-

   2%

The LD200 is a dual channel inductive loop detector. The use of microprocessor and surface mount  
technology enables a large number of functions to be incorporated into a small package. The LD200 is 
compatible with most single channel detectors on the market and is easy to set-up and install.

Typical applications in the parking and access control environments are safety loops, arming loops and 
entry or exit loops as well as direction logic.
Standard features of the detector are:

!

RESET SWITCH

      Pressing the reset switch enables the detector to be manually reset during commissioning and          

and testing. This results in the detector re-tunning the sensing loop and becoming ready for               
vehicle detection.

!

SWITCH SELECTABLE SENSITIVITY

      The detect sensitivity is the minimum change in inductance required to produce a detect output.                   

(%   L/L).

 

Eight sensitivity settings are available on the switches to allow flexibility in configuration.

!

SWITCH SELECTABLE FREQUENCY

      The frequency of the loop is determined by the inductance of the loop and the frequency switch           

setting. If the frequency switch is on, the frequency is reduced. It may be necessary to change the      
frequency to prevent cross-talk between adjacent loops.

!

SELECTABLE EXTEND TIME

When switched on this feature extends the outputs for 2 seconds.

!

PULSE RELAY SELECTION

The detect relay may be configured for a pulse output, and to energise on detection of a vehicle or      
when the vehicle leaves the loop.

!

SELECTABLE N/O OR N/C RELAY OUTPUT

Internal jumpers enable the output relay contacts to be configured for normally open or normally           
closed contacts.

!

DIRECTION LOGIC

This feature enables the detector to give a pulse output on relay 1 for a vehicle travelling from loop      
1 to loop 2 and a pulse output on relay 2 for a vehicle travelling from loop 2 to loop 1. To enable this      
feature switches 2 and 4 must be on.

!

SELECTABLE PULSE TIME

This feature sets the length of time that the pulse will be energised for. 1 Second or 0.2 Second.

!

POWER INDICATOR

This LED indicator illuminates when power is present.

LD200 SERIES

VEHICLE LOOP DETECTOR

LD200 SERIES

VEHICLE LOOP DETECTOR

Отзывы: