Centsys Lattice Скачать руководство пользователя страница 1

NETWORKED

PROXIMITY ACCESS

CONTROL SYSTEM

LATTICE Installation manual 

Содержание Lattice

Страница 1: ...NETWORKED PROXIMITY ACCESS CONTROL SYSTEM LATTICE Installation manual...

Страница 2: ...pecification Through a team of dedicated technicians and sales personnel together with a fully fledged in house training facility we are committed to providing unmatched service to our customers and s...

Страница 3: ...eads LSH 17 Setting the Lattice Slave Head Address 19 Programming the Lattice System 20 First Time Operation 20 Programming the System 20 Getting into Programming Mode 22 Basic Menu 23 Quik Learn 23 B...

Страница 4: ...presented This provides a method of controlling how many times a person may use a particular asset e g photostat machine sauna etc Complex programming of the system can be done using only a single Adm...

Страница 5: ...ained L1000 Controller The Master controller in the system which can be used as a standalone reader head or can be interfaced with remote slave heads Lattice slave head LSH A Lattice slave head is an...

Страница 6: ...a change room where dirty clothes are removed then into a clean room and then into an operating theatre By defining the outside as zone 0 the change room as zone 1 the clean room as zone 2 and the th...

Страница 7: ...or sense input Anti tamper switch Operational Tag capacity Tag read range Alarm output time s Physical 10 12VAC 12 15V DC 50mA 180mA 20 C to 50 C 0 90 non condensing 13 56 MHz ABS UV Stabilised IP55 1...

Страница 8: ...Required SILICON 5mm Masonry Bit Silicon Cable 0 20mm Level Level Tape Measure Long Nose Pliers Side Cutters Star Screwdriver 0 and 1 point 0 50mm 0 75mm Drilling Machine hammer action Multi Meter Fl...

Страница 9: ...o the driveway The reader is not set too far back and cannot easily be accessed from a vehicle The height allows for the presenting of the tag to be comfortable from a vehicle An anti knock shield is...

Страница 10: ...y bulkhead A in the housing Additional slots can be cut out to accommodate further cables if necessary 7 Fit a cable tie around the cable as shown When tightened this holds the cable in position and p...

Страница 11: ...frame A and fold down into position ensuring the cable is not caught B 12 Fasten controller housing into position using the 2 x M4 pan head screws provided in the kit Optional cable tie B A B B 8B 8C...

Страница 12: ...d for either steel or masonry wood mounting Incorrect configuration will result in poor read range or unreliable operation Page 12 Fig 1 Layout of Lattice L1000 Controller NB Solder link pads for stee...

Страница 13: ......

Страница 14: ...e free contact closed when door is closed Common connected to CHD External Alarm output open collector Positive connected to CHD Maximum current 50mA Smart Switch II positive 12V DC Smart Switch II ne...

Страница 15: ...the input voltage is not critical The following diagrams apply to both the L1000 Controller and the Lattice slave heads unless otherwise stated CHD CHD CHD ALARM DOOR SEN FRX FIRE L N E CP84E PSU RED...

Страница 16: ...TUH Controller L1000 Controller L1000 N O COM N C RS485A RS485B RS485C COM PC TX Tx P1 Twisted Pair Cable max 150 metres Rx P2 PC RX Lattice Slave Head N O COM N C RS485A RS485A RS485B RS485B RS485C R...

Страница 17: ...Fig 9 Wiring to a solenoid type door lock 12V Battery N O COM N C RS485A RS485B RS485C PC TX PC RX L N E CP84E PSU Solenoid Lock RED BLK AC Mains SOL SOL Magnetic Door Lock Wiring Solenoid Lock Wirin...

Страница 18: ...1000 and the RSH have 100 ohm resistors built into them and thus all that has to be done is to decide which two devices happen to be at the end of the line and those resistors are then switched into c...

Страница 19: ...per is bridged if EOL resistor needs to be connected Part of L1000 PCB Fig 12 Part of L1000 showing jumper link that turns on EOL Resistor Fig 13 Part of LSH showing dipswitch that turns on EOL resist...

Страница 20: ...to the LSH number 0 OFF 1 ON 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 LSH 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Sw 2 0 0 0 0 0 0 0 1...

Страница 21: ...he Admin tag This tag can be thought of as a type of master tag but it is termed the Admin tag due to the fact that system administra tion is done using this tag Administration involves adding and del...

Страница 22: ...ented to the L1000 displays ASC This display indicates that the tag is not associated with the L1000 even thought it may be fully functional on the remote slave heads To indicate that the tag is valid...

Страница 23: ...ed functionality is required Most of the standard run of the mill programming can be done from the BASIC menu Please see list of abbreviations at the end of this manual for a detailed abbreviation lis...

Страница 24: ...Exit to Previous Menu At this stage the system is ready to have new tags learned in Tag 1 has now been learned into ID Number 001 1 4 2 5a 3 5b Tag 2 has now been learned in etc etc 6 7a 7b TM Descri...

Страница 25: ...reen LED is ON then the count increases as the tag is presented If the red LED is ON then the count decreases as the tag is presented the red and green LED s alternate if a tag is not presented if the...

Страница 26: ...ing the red and green LED on the L1000 Each time the tag is removed the LEDs will toggle If the Red LED is ON it means that the tag will not operated on this head and if the Green LED is ON the tag wi...

Страница 27: ...main menu to ID of level 1 2 2 Present and remove to scroll vertically through the options in level 1 Options are ID deletes any tags stored in a particular ID location across heads in the system ErA...

Страница 28: ...turns to the ErA display If YES was selected the display will momentarily flash up bSY an abbreviation for Busy and then dNE an abbreviation for Done to indicate that all tags have been erased If was...

Страница 29: ...e the Admin tag to scroll vertically through the following options in level 2 On Turns ON the Advanced User Structure OFF Turns OFF the Advanced User Structure Exit to previous menu 3 2 3 Present and...

Страница 30: ...e system The TM flow diagram below shows the QUIK Learn Procedure and is described fully below Advanced Menu The Advanced Menu Structure comprises the following first level sub menus Each of these men...

Страница 31: ...here is an alternative way to enter new tags which provides the ability to set all the attributes for a tag The menu structure is shown in Figures 21 and 22 Icon No TM Table 4 Quik Learn Description T...

Страница 32: ...optionally heads H 01 to H 31 are set it is critical that A is selected present and hold the NEW tag to save all the settings that may have been made to levels 4 onwards to all the readers NOTE If the...

Страница 33: ...Yes specifies that the head will permit valid OLA tags to operate even off line 1 2 6 The various options in level 6 depend again on what was selected in level 5 For example 1 2 6 1 Depending on wheth...

Страница 34: ...Level 1 Level 2 Level 4 Level 3 Level 5 Level 6 Channel 2 applies to Controller only Option 1 Save New Tag and Return to Process Next Tag Option 2 Exit to Main Menu Option 3 Move to top of Menu Eg ID...

Страница 35: ...arn Menu Structure page 2 Main Level 1 Level 4 Level Level 5 Level 6 A Only displayed for heads H 01 to H 31 from previous page Figure 21 Select Limited Uses Counters Select Off Line Association Exit...

Страница 36: ...scribed previously 2 3 1 2 When the correct ID is selected WAIT 2 3 1 3 When the display changes to SEt present and remove the Admin tag If successful the display will flash dnE and return to Id to al...

Страница 37: ...s back to tAg n n A B EXIT to previous Menu WARNING This action is irreversible See 3 3 5 3 Only ID s linked to head will be listed to top of Level to top of Menu to top of Menu Delete by Tag To next...

Страница 38: ......

Страница 39: ...OUNT INSTALLATION DRILL 5mm DRILL 5mm DO NOT ALLOW CABLE ACCESS THROUGH THIS AREA 1 2 3 3 PREFERRED CONDUIT LOCATION PREFERRED CONDUIT LOCATION LOCATION CONDUIT LOCATION CONDUIT NOT RECOMMENDED NOT RE...

Страница 40: ...of the unit after installation Place the template in such a manner that conduit where provided will be behind one of the four preferred conduit locations shown alongside If conduit is not provided sur...

Страница 41: ......

Страница 42: ...level 4 by presenting and holding the Admin tag 2 3 3 4 1 Rotate vertically through the selections yES delete all tags No do NOT delete all tags or exit to previous menu by presenting and removing the...

Страница 43: ...ore fully below 3 4 1 Hd Head settings If HdS was selected the display will indicate Con This sub menu allows the parameters of the main controller L1000 or any of the attached LSH s i e H 01 to H31 t...

Страница 44: ...5 the relay will latch If the time needs to be adjusted present and hold the Admin tag and the display will indicate the existing time setting stored in memory 3 4 1 2 rt2 Relay Time 2 i e The pulse t...

Страница 45: ...her a buzzer sounds when a tag is presented 3 4 1 13 2 FFP Free Exit Fire Panic This sets whether the FRX input acts as a free exit a fire or a panic input 3 4 1 13 3 dFS Door open on fire signal This...

Страница 46: ...lly through the options On Turns the Advanced Menu ON OFF Turns the Advanced Menu OFF Exits to previous menu 3 4 3 3 Present and hold the Admin tag for 5 seconds to activate the setting selected in 3...

Страница 47: ...4 5 bnr Backup and Restore 3 4 5 1 bup Backup 3 4 5 2 rSt Restore 3 4 6 PCS P C System Allow the user to specify if a P C is connected to the L1000 3 4 7 SUP Supply Voltage Display the current supply...

Страница 48: ...1a Display Brightness Percentage increases in 10 steps Select one of the options or exit Select Display Brightness continued in Figure 27 continued in Figure 26 Level 1 Level 3 Level 2 A Main B EXIT t...

Страница 49: ...1 Level 3 Level 2 Main B EXIT to previous Menu Fig 26 Part 1b of Configure Menu Structure Select one of the options or exit From Figure 25 Create Additional Admin Tags Display Firmware Revision Firmwa...

Страница 50: ...applies only to the L1000 Controller which has a second relay to control door 2 select one of the options or exit continued in Figure 28 from Figure 25 Level 2 Level 3 Level 5 Level 4 Level 6 WAIT WA...

Страница 51: ...Level 4 Level 6 C EXIT to previous Menu from Figure 27 Select Buzzer Volume Select Free Exit Fire or Panic Option Exit Switch Alarm ON or OFF to top of Menu select one of the options or exit select o...

Страница 52: ...isplay will indicate NO 4 3 1 1 If NO is selected by presenting and holding the Admin tag for 5 seconds the system will revert back to ALL This is the escape route if it is decided NOT to 4 Update Men...

Страница 53: ...ed Update Tag Menu Structure part 1a Main Level 1 Level 3 Level 2 Level 4 Level 5 WAIT A B A B C EXIT to previous Menu Update by ID Update by Tag Update Tags by Head Save or Exit to Fig 31 Delete ALL...

Страница 54: ...n 3 Level n 2 Level n 4 from Figure 29 A D EXIT to previous Menu Fig 30 Part 2a of Update Tag Menu Structure to top of Menu to top of Menu to top of Menu to top of Menu to top of Menu to top of Menu s...

Страница 55: ...es Counters Update Offline Associations D select one of the options or exit select one of the options or exit Fig 32 Part 2b of Update Tag Menu Structure to top of Menu Advanced Update Tag Menu Struct...

Страница 56: ...Once the head is selected by presenting and holding the Admin tag for 5 seconds the display will move from level n 1 to level n 2 indicated by ASC 4 3 3 6 Presenting and removing the Admin tag will s...

Страница 57: ...exit to an APB zone defined by the In or Out selection respectively is made by scrolling vertically through the options In Out or if exit to a previous level is required by presenting and removing the...

Страница 58: ...ALL Id tAg or exit to previous menu is done by presenting and removing the Admin tag 4 3 4 4 If ALL tags must be updated move to level 4 by presenting and holding the Admin tag 4 3 4 4 1 Rotate vertic...

Страница 59: ...a specific tag to others This is a very convenient and easy way to set up tags on a system There are two main ways in which tags can be copied The first is a known as duplicate where an existing tag i...

Страница 60: ...All new tags take on the same ID number eg 122 n n First tag takes on next available ID Number eg 023 Each new tag increments previous ID by 1 n increments after each new tag e g n 017 n remains 122...

Страница 61: ...he incremented value e g n 1 017 now If a second new tag in presented it will be allocated to this new incremented ID etc etc 5 6 If n Copy Multiple Tags to Single Id is selected by presenting and hol...

Страница 62: ...ss Using the Template menu structure as a guide the following steps are followed 6 1 The Admin tag is presented and held for 5 seconds to get from tPL of the Admin menu to where the display indicates...

Страница 63: ...enu to top of Menu CH2 applies to controller only B A EXIT to previous Menu Advanced Template Menu Structure part 1 Advanced Template Menu Structure part 1 Advanced Template Menu Structure part 1 Main...

Страница 64: ...01 to H 31 Advanced Template Menu Structure part 2 Main Level 1 Level 3 Level 2 Level 4 Level 5 B A WAIT eg ID 041 Fig 35 Template Menu Structure Part 2 from Figure 34 Create Template from ID Create T...

Страница 65: ...ous level is required The selection is made by presenting and removing the Admin tag for 5 seconds E g if ASC is displayed and the Admin tag is presented and held for 5 seconds then the display change...

Страница 66: ...or this reader is selected by scrolling vertically through the options On Counter will be operational at this Lead OFF Counter will not be operational at this Lead if exit to a previous level is requi...

Страница 67: ...tags etc Anti passback Association refers to a tag not being linked to a reader i e no association Busy flashes momentarily during updating or deleting tags Buzzer Buzzer Volume set to High Buzzer Vol...

Страница 68: ...ve of the latest revision e g V1 01 Flashing bar to indicate normal run mode Free Exit refers to FRX FIRE input being used as a free exit input Free Exit Fire or Panic Input Select Menu Full indicates...

Страница 69: ...to whether a relay is On Off etc Out refers to exit direction during anti pass back Panic refers to FRX FIRE input being used as a Panic input Present a new Tag Prewarn time before door open prewarn s...

Страница 70: ...is presented and removed i e Swiped past the reader Present Hold Existing Tag This icon symbolises that an existing user tag is presented and held for 5 seconds Incrementation with the Admin Tag This...

Страница 71: ...ttice Quick User Guide LatticeWare Software Manual Solo Standalone Proximity Reader Lattice Brochure Lattice Application Notes Reference 1166 D 01 1166 D 01 1166 D 01 1166 D 02 0003_2 1166 D Additiona...

Страница 72: ...Page 67 Firmware Revision 1 01 Manual Revision 1 Description of Changes Original Issue Revision History Revision History...

Страница 73: ...Page 68 Installation Details Installation Date Installer s Name Installer s Address Installation Checked By Installer s Telephone Number...

Страница 74: ...Notes Notes Page 69...

Страница 75: ...Notes Notes Page 70...

Страница 76: ...Notes Notes Page 71...

Страница 77: ...www centsys com au 0 07 B 0027 Lattice Installation Manual 10Jul2012...