background image

69K-143 

69K-144 

69K-145 

MILK COOLERS 

Service, Installation and Care Manual 

IMPORTANT INFORMATION 
PLEASE READ CARFEULLY 

Содержание 69K-143

Страница 1: ...69K 143 69K 144 69K 145 MILK COOLERS Service Installation and Care Manual IMPORTANT INFORMATION PLEASE READ CARFEULLY ...

Страница 2: ... COOLER 6 INSTALLATION 6 7 ELECTRICAL CONNECTION 7 FOOD STORAGE 7 OPERATINGINSTRUCTIONS 7 9 MAINTENANCE 9 10 TROUBLESHOOTING 11 DISPOSAL 12 SPECIAL POINTS TO NOTE 12 EXPLODED VIEW ANDPARTS LISTING 13 WIRING CIRCUIT DIAGRAM 14 READ THIS MANUAL COMPLETELY BEFORE ATTEMPTING TO INSTALL OR OPERATE THIS EQUIPMENT SAVE THESE INSTRUCTIONS NOTIFY CARRIER OF DAMAGE INSPECT ALL COMPONENTS IMMEDIATELY ...

Страница 3: ...xterior of the package and skid or container Any damage should be noted and reported to the delivering carrier immediately 2 If damaged open and inspect the contents with the carrier 3 In the event that the exterior is not damaged yet upon opening there is concealed damage to the equipment notify the carrier Notification should be made verbally as well as in written form 4 Request an inspection by...

Страница 4: ...ry and let you know what can happen if the instructions are not followed If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been g...

Страница 5: ...ing conditions Do not reload contents until the interior is at the desired temperature WARNING Do not damage the refrigerant circuit Operating moving and use of the milk coolers must avoid either damaging the refrigerant tubing or increasing the risk of a leak by impacting other objects or attempting to drill into the unit CAUTION Risk Of Fire Or Explosion Due To Puncture Of Refrigerant Tubing Fol...

Страница 6: ...space for air circulation to the rear of the unit Recommended space between the rear of the unit to the wall is at least 5 inches 2 FOUNDATION Please make sure that the floor where the unit will be placed can support the total weight plus any other contents that it may hold 3 DO NOT PLACE NEAR HEAT Please make sure to avoid hot corners and locations near stoves High ambient temperature will signif...

Страница 7: ...the height limit of the included contents fill level line or in cases where there is no such line to within 100mm below the lid This is to ensure the product temperature remains less than 40 F The temperature in the cooler is automatically regulated by a set thermostat The position of the cooler the ambient temperature the number of times the lid is opened and for how long the lid is opened are al...

Страница 8: ... immediately release the SET key or wait for 5 seconds to display the sensor valueagain 2 2 HOW TO CHANGE THE SETPOINT 1 Hold the SET key for more than 2 seconds to change the set point value 2 The value of the set point will be displayed and the LED starts blinking 3 To change the set value push the or key within 10s 4 To set a new point value push the SET key again or wait 10s 2 3 HOW TO START A...

Страница 9: ...an cloth or sponge Rinse surfaces with clean warm water and dry immediately to avoid water spots DO NOT USE Abrasive or harsh cleaners Ammonia Chlorine bleach Concentrated detergents or solvents Metal or plastic textured scouring pads Vinegar based products Citrus based cleaners Detergents that contain chlorine Note It suggested that the unit be emptied daily after all peak demand periods have pas...

Страница 10: ...re fitted at the back bottom of the cooler they can gather dust and dirt If cleaning is necessary they should be vacuumed with a soft brush 4 Please note that the parts behind the protective grill can be hot and rotating 5 POWER CORD 5 1 Please make sure that the power cord is connected to the proper voltage The power cord must be connected to a protected circuit with the correct voltage and amper...

Страница 11: ... not in the correct position Check the installation and adjust the tray position There is condensation on the exterior of the unit High moisture air can produce condensation on an external surface Wipe with a dry cloth Ice is covering the interior walls and the unit is to warm Ice is an insulator the unit has built up ice and needs to be defrosted Empty unit and put the milk cartons in a refrigera...

Страница 12: ...ese instructions for use was correct at the term of printing On account of our constant produce development however we reserve the right to make changes in the cooler described here Naturally we will attempt to keep instructions for use up to date If you are in doubt as to the correct use of the cooler please contact your supplier who will be able to advise you The manufacture distributor is not r...

Страница 13: ...L WHEEL 5 DOOR SEAL 22 THERMOSTAT 6 LOCATION KNOB 23 THERMOSTAT BOX 7 HOOK PLATE 24 THERMOSTAT BOX COVER 8 LOCK HOOK 25 SEAL 9 FRONT DOOR 26 SENSOR FIXED CLIP 10 SUCTION PIPE CAPILLARY 27 PROBE PADDING 11 COMPRESSOR 28 LOCATION AXIS 12 CODENSER FAN 29 ROTATING AIXS 13 BASKET GUARD GRILLS 30 HINGE PLATE 14 FILTER DRIER 31 BODY 15 DRIER SUPPORT 32 HOOK 16 CONNECTION PLATE 33 UNIT ROOM COVER 17 BLADE...

Страница 14: ...Service and InstallationManual 14 WIRING DIAGRAM MODEL 69K 143 69K 144 69K 145 ...

Страница 15: ...Service and InstallationManual 15 NOTES ...

Страница 16: ...Service and InstallationManual 16 7750 Georgetown Road Indianapolis IN 46268 800 289 3637 Fax 800 882 0086 ...

Отзывы: