VeriFast
TM
LVDT – User Manual – FDP-VFA-LVD-UM-EL-1.15-0918
21
4.
Mount the weld body on the sub-plate
using the four (4) socket head screws
and Nord-Lock washers provided with
the equipment. Tighten the screws to
17.63 N·m (13 ft. lbs).
Mounting the Signal Conditioner
The Signal Conditioner is configured to be mounted on a standard DIN rail.
Wiring the VeriFast LVDT and Signal Conditioner
Use a 5-pin shielded cable to establish the connection between the VeriFast LVDT Electrode
and Signal Conditioner (see Figure 3 below). Use separate wiring (not shown) to connect the
Signal Conditioner to the PLC.
Figure 3 – Wiring the VeriFast LVDT and Signal Conditioner
VeriFast™ LVDT Electrode
(any configuration)
Signal Conditioner
Micro 12 mm, 5-pin, shielded female cord
Micro 12 mm, 5-pin, plug connector
(Male)
(Female)
Wiring between
Signal Conditioner
and PLC
A
.
C
.
B
.
DO NOT
DISCONNECT
Damage will occur