manualshive.com logo in svg
background image

CABLE TESTER&DIGITAL MULTIMETER 

 

Cable Identifier&DMM  

User’s Guide 

 

 

 

 

 

 

 

 

   

 

OP

ON

CABLE TESTER

CABLE IDENTIFIER

CABLE TESTER

CABLE IDENTIFIER

Vcheck

Содержание LA-1015

Страница 1: ...CABLE TESTER DIGITAL MULTIMETER Cable Identifier DMM User s Guide OP ON CABLE TESTER CABLEIDENTIFIER CABLE TESTER CABLEIDENTIFIER Vcheck...

Страница 2: ...2 2 Receiver Description 4 2 3 Digital Multimeter Description 4 3 SPECIFICTIONS TETHNICAL DATA 4 3 1DMM 4 5 3 2Transmitter 6 3 3 Receiver 6 4 MEASURING PROCEDURE 7 4 1 Transmitter Receiver operation...

Страница 3: ...cores at either end of a multi core cable With the remote kit it can tester cables installed far away either on wall plate or patch panel Digital multimeter function make it easy to measure DC AC vol...

Страница 4: ...4 3 SPECIFICTIONS TETHNICAL DATA 3 1 DMM...

Страница 5: ...200 0 0 8 rdg 5d 2 000k 20 00k 200 0k 1 2 rdg 3d 2 000M 2 0 rdg 5d 20 00M 5 0 rdg 8d Max input voltage 600V AC DC Diode Test Test current 1mA max open circuit voltage of 1 5V typical Continuity Check...

Страница 6: ...600V Pollution degree II CE Approved 3 2 Transmitter Display Two red LED lamps Aligators 17Croc clips red 16 black 1 Cable resistance 30K Ohm max Power 9V battery Power current 1 8mA Operating temper...

Страница 7: ...is successively touched on the cores of the cable under test the relevant number of the way is indicated on the display of the receiver 1 16 Operation example 1 Cable trace test Operation example 2 Me...

Страница 8: ...o the negative COM terminal and the red test lead into the positive V terminal 2 Set the function switch to VAC or VDC position 3 Connect the test leads in parallel to the circuit under test 4 Read th...

Страница 9: ...uch the red test probe tip to the positive side of the circuit 7 Apply power to the circuit 8 Read the current in the display RESISTANCE MEASUREMENT 1 Set the function switch to the position 2 Insert...

Страница 10: ...egative COM terminal and the red test lead into the positive terminal 4 Touch the test probe tips to the circuit or wire you wish to check 5 If the resistance is less than approximately 150 the audibl...

Страница 11: ...tton The meter reading will not change as readings change 2 Press the MAX hold button again to return to normal operation Hold Button The Data Hold function allows the meter to freeze a measurement fo...

Страница 12: ...of the proper size and value 0 2A 250V fast blow for the 200mA range 8 Align the center board with the connectors and gently press into place 9 Replace and secure the rear cover battery and battery c...

Страница 13: ...13 2 Remove the bottom cover and secure the screw 3 Replace old battery with fresh two 1 5V AAA or 9V type batery 4 Replace the bottom cover and secure the screw...