CEM DT-610B Скачать руководство пользователя страница 1

1¡ ã

Tc

C

¡ ã

K

F

¡ ã

BACK-
LIGHT

1

0. ¡ ã

+

MAX HOLD

F

¡ ã

K

C

¡ ã

     

  OPERATING INSTRUCTIONS 

 

 

 

DIGITAL THERMOMETER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INTRODUCTION 

This  instrument  is  a  portable  3

1

/

2

  digit.,  compact-sized 

digital  thermometer  designed  to  use  external  K-type 
thermocouple 

as 

temperature 

sensor. 

Temperature 

indication  follows  National  Bureau  of  Standards  and 
IEC584 

temperature/voltage 

tables 

for 

K-type 

thermocouples.  One  K-type  thermocouples  is  supplied 
with the thermometer. 
 

SAFETY INFORMATION 

It  is  recommended  that  you  read  the  safety  and  operation 
instructions before using the thermometer. 

WARNING 

TO AVOID ELECTRICAL SHOCK. DO NTO USE THIS 
INSTRUMENT 

WHEN 

VOLTAGES 

AT 

THE 

MEASUREMENT  SURFACE  EXCEED  24V  AC  OR  60V 
DC. 

WARNING 

TO  AVOID  DAMAGE  OR  BURNS.  DO  NOT  MAKE 
TEMPERATURE  MEASUREMENTS  IN  MICROWAVE 
OVENS. 

CAUTION 

Repeated sharp flexing can break the thermocouple leads. 
To  prolong  lead  life,  avoid  sharp  bends  in  the  leads, 
especially near the connector. 
The        symbol  on  the  instrument  indicates  that  the 
operator must refer to “

Input protection

” in this manual. 

 

SPECIFICATIONS ELECTRICAL 

Temperature Scale: 

Celsius  (

)

,  Fahrenheit  (

)

  or  Kelvin  (

K) 

user-selectble 

Measurement Range: 

-50

  to 1300

, -58

  to 2000

, 223K to 2000K 

Resolution: 

1

  or 1

, 0.1

  or 0.1

,1 K 

Accuracy: 

Accuracy  is  specified  for  operating  temperatures  over  the 
range of 18

to 28

(64

  to 82

), for l year, not including 

thermocouple error. 

±

2

----------------------    -50

  to 0

 

±

4

----------------------    -58

  to 32

 

±

5K----------------------    223K to 273K 

±

(0.5% rdg+1

)--------    0

  to 1000

 

±

(0.8% rdg+1

)--------    1000

  to 1300

 

±

(0.5% rdg+2

)--------    32

to 2000

 

±

(1.0% rdg+2K)--------    273Kto 2000K 

 

Temperature Coefficient: 

0.1  times  the  applicable  accuracy  specification  per 

 

from 0

  to 18

  and 28

  to 50

  (32

  to 64

  and 

82

  to 122

). 

Input protection: 

60V  dc  or  24V  rms  ac  maximum  input  voltage  on  any 
combination of input pins. 

Reading Rate: 

2.5 times per second. 

Input Connector: 

Accepts standard miniature thermocouple connectors (flat blades 
spaced 7.9mm, center to center). 
 

ENVIRONMENTAL 
Ambient Operating Range: 

0

  to 50

  (32

  to 122

Storage Temperature: 
-20

  to 60

  (-4

  to 140

Relative Humidity: 

0% to 80% (0

  to 35

) (32

  to 95

0% to 70% (35

  to 50

) (95

  to 122

 

GENERAL 
Display: 

3

1

/

2

  digit  liquid  crystal  display  (LCD)  with  maximum 

reading of 1999 

Battery: 

Standard 9V battery (NEDA 1604, IEC 6F22) 

Dimensions: 

162mm (H)

×

76mm(W)

×

38.5mm(D) 

Weight: 

210g 

Supplied Probe:   

4  foot  type"K"thermocouple  bead  probe  (Teflon  tape 
insulated). 
Maximum insulation temperature 260

(500

)   

Probe  accuracy

±

2.2

  or 

±

0.75%  of  reading 

(Whichever is greater) from 0

°

to 800

 

 

OPERATING INSTRUCTIONS 
Selecting the Temperature Scale 

Readings  are  displayed  in  either  degrees  Celsius  (

), 

degrees Fahrenheit (

) or degrees 

Kelvin

 (K).When the 

thermometer is turned on, it is set to the temperature scale 
that was in use when the thermometer was last turned off. 
To  change  the  temperature  scale,  press  the  For

,

or  K 

key. 

Отзывы: