7.3 Removing and fitting the visors
The visors are fitted on the side of the machine on which the blade guard is mounted.
The visors can be mounted on both sides of the machine The procedure for the left side is
described in the following handling instructions.
7.3.1
Removing the visors
Prerequisite:
•
The machine is switched off and secured against accidental switch-on (see Page 108:
Operation > Daily shut-down).
Required:
•
Spanner (WAF 17)
Carry out the following steps:
1.
Use a spanner (WAF 17) to loosen the two
‹
visor
clamping
screws
›
on the
‹
telescopic
rod
›
.
2.
Pull the
‹
front
visor
›
out of the
‹
telescopic
rod
›
.
The front visor has been removed.
Removing