![Cedima 14102000 C Скачать руководство пользователя страница 85](http://html1.mh-extra.com/html/cedima/14102000-c/14102000-c_translation-of-the-original-operating-manual_2578798085.webp)
Cedima • Technical Documentation • Joint Cutter CF•1020 D • Issue date: 21/09/2021
85
Troubleshooting
Maintenance, Repairs and Shut-Down
Engine troubleshooting (cont.)
Problem
Possible Cause
Remedy
No power when cutting,
engine shuts off.
V-belt slips, is defective.
Tension V-belts or replace.
Cutting pressure too high.
Reduce feed and, if necessary, cutting depth.
8.4.2 Cutting problems
Instructions on troubleshooting during cutting:
• The problems and their possible causes are mostly a result of natural wear and tear and
in the improper use of the machine and the diamond saw blades.
• Read through the operating manual carefully before cutting.
Troubleshooting during cutting
Problem
Possible Cause
Remedy
Diamond saw blade
wobbles
Insufficient blade tension
Send diamond saw blade to manufacturer.
Diamond saw blade has
horizontal and/or vertical
"wobble"
Diamond saw blade is dam-
aged or belt
Have diamond saw blade straightened.
Solder the diamond segments onto a new blade
core.
Use a new diamond saw blade.
Blade flange(s) are soiled or
defective
Clean blade flange(s) and replace if necessary.
Diamond segments be-
come detached
Diamond saw blade is over-
heated, insufficient cooling
Solder diamond sections on again.
Optimise cooling water supply:
• Check the position of the water valve.
• Clean the dirt sieve of the flushing water connec-
tion.
• Check the correct seating of the blade guard on
the blade guard holder.
• Check the correct seating of the protective cover
of the cutting shaft on the blade guard holder.
• Check the water pump impeller and replace the
impeller if necessary.