Cedes cegard/Max Скачать руководство пользователя страница 1

CEDES 

 

© 

CEDES

 

 

   Part No. 106 258 201125

 

 

 

 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 

 
 
 

 

Installation and Operation Manual 

(North America Version)

 

Light Curtain for 

Elevator Door Protection 

cegard/Max-NT  

Содержание cegard/Max

Страница 1: ...CEDES CEDES Part No 106 258 201125 Installation and Operation Manual North America Version Light Curtain for Elevator Door Protection cegard Max NT...

Страница 2: ...B44 19 SAFETY CODE FOR ELEVATORS AND ESCALATORS OR LATER VERSIONS DUE TO NEW REQUIREMENTS FOR SELF MONITORING AND INTEGRATION OF APPROACHING OBJECT DETECTION CONTACT YOUR LOCAL CEDES REPRESENTATIVE I...

Страница 3: ...Max NT control unit is mounted within reach of the ends of the transmitter and receiver cables e g on the car top or in a nearby operating panel The con trol unit acts as an interface between the ligh...

Страница 4: ...taken out of service to pre vent movement during installation e g lockout ta gout procedure 4 Install the transmitter receiver with the mounting or spacer profile to the door wings or to the slam pos...

Страница 5: ...occurs It is important that the alignment angle of the transmitter to the receiver is less than 10 when the door is fully closed We recommend that you keep the optical angle close to zero see Figures...

Страница 6: ...s are mounted As shown in Figure 4 guide the cables of the transmitter and receiver to the control unit A small bending radius reduces the cable lifetime dramatically Use the cable binder A to fix the...

Страница 7: ...trance gaskets to connect the transmitter the receiver the output relay and power Connect all wiring with more than 42 V through a Greenfield Fitting Disconnect power before opening the control unit t...

Страница 8: ...he Fire Recall Phase I input is deactivated Fire Recall Phase II If the input labeled Fire Recall Phase II is activated the light curtain output is disabled The nudging function works independent of F...

Страница 9: ...urtain contact after nudging triggers In other cases it is not necessary This issue was discovered in Canada and therefore the switch is dubbed the Ameri can Canadian nudging option American Version L...

Страница 10: ...function is very helpful after installation to check the proper function of the light curtain To shut off all audible signals set both the obstruction buzzer and the nudging buzzer switches to the OF...

Страница 11: ...trans mitter edge This may cause damage to the components and prevent proper operation We strongly recommend using standard window cleaner or soap and water for cleaning 4 8 Disposal The cegard Max N...

Страница 12: ...ion Random door opening or Are sensors or vision shields dirty Excessive EMC interference e g from door drive or fluo rescent lamps No or bad grounding PE connection Damaged cable to the receiver or t...

Страница 13: ...17 265 VAC DC Inactive 0 5 VAC DC Ambient light resistance 100 000 Lux Temperature range Operation Storage and transport 5 to 150 F 20 65 C 20 to 220 F 30 85 C Maximum Door speed 5 3 ft s 1 6 m s Stan...

Страница 14: ...7 0 28 1799 4 70 84 1742 0 68 58 1684 6 66 32 1627 2 64 06 1569 8 61 80 1512 4 59 54 1455 0 57 28 1397 6 55 02 1340 2 52 76 1282 8 50 50 1225 4 48 24 1168 0 45 98 1110 6 43 72 1053 2 41 46 995 8 39 20...

Страница 15: ...itter Unit 1 102 788 cegard Max Receiver Cable 16 ft 5 m Length 1 102 787 cegard Max Transmitter Cable 16 ft 5 m Length 1 102 995 Cable Guide Wire 2 102 973 Spacer Profile 7 ft Length 2 102 751 Mounti...

Страница 16: ...nual CEDES Corporation of America Tel 1 612 424 8400 Fax 1 952 426 1519 info ameri cas cedes com www cedes com CEDES AG is certified according to ISO 9001 2015 CEDES AG reserves the right to modify or...