background image

CYCLIC TIMER (50 sec. to 30 min.) With TRIAC.

TIMER.

I-22

I-22

I-22

I-22

The I-22 is a 230 VAC cyclic timer with Triac output, which only accept resitive loads and not inductive loads. The 
module will maintain activated the output according to an operating time and a quiescent time fluctuating 
between 50 seconds and 30 minutes. 
The operating-quiescent cycle  will be activated until you stop to supply the module. 
You could activate the module by closing contacts. It includes terminals to connect it. 

POWER SUPPLY. 

The Circuit I-22 had to be supplied by 230 VAC. According to the General Wiring Map  to 

correctly use the circuit we suggest you to insulate the circuit against possible parasites (interferences) inserting 
a 230 VAC filter at the supply input. Please take note of the Chapter "Filter". 
Using an adequate plug and a cable for mains connect this last one to the input terminal 230 VAC. Install a 
fuse and a switch as it is indicated in General Wiring Map (see hereafter). Both are necessary to protect the 
module and for your own security, as it is indicated in EEC regulations. Then, verify that you have correctly 
connected the module. 
Before to connect the module to the mains inserting voltage, please do the rest of connections specified 
hereafter. 

Don't forget that in several part of the module there is voltage (230 VAC),

 for this reason we 

suggest you to be carreful.

OPERATING-QUIESCENT CYCLE. 

The circuit have two times. Operating time (when the relay will be connected) 

and quiescent time (when the relay will not be connected between two operating time).
To select operating and quiescent times you had to adjust potentiometers inserted in the P.C.B. 
When the time is selected, press the push button to supply the module. The circuit I-22 will automatically 
connect the output during the previously indicated operating time and the led will light. When the operating 
time will be finished, led and output will be disconnected during the selected quiescent time. At the end of this 

Voltage..........................................................................................

230 V. A.C.

Medium Consumption..................................................................

1 W.

Minimum Time..............................................................................

50 Sec. 

Maximum Time.............................................................................

30 Min.

Minimum Load..............................................................................

50 W.

Maximum Load.............................................................................

500 W.

Ref. FULL9735_Ang.

1

1

2

2

OPERATING.

TECHNICAL CHARACTERISTICS.

GENERAL WIRING MAP.

Module

I-22

230 V. C.A.

230 V. A.C. Mains

Time turn on

Time turn off

Input

230 V.

Output

230 V.

Fuse 

1.5 A.

Switch

Load,

Charge

Load,

Charge

HOW TO INSTALL THE FILTER.

230 V. A.C. Mains.

230 V. A.C. Output.

Mains filtred to the circuit.

Ground

FILTER

IN

P

U

T

 2

30

 V

. A

.C

.

O

U

T

P

U

T

  2

30

 V

. A

.C

quiescent time, the module I-22 will be activated once again. 

OUTPUT. CONNECTION OF THE LOAD. 

The output Module (I-22) accept resistive loads as lamps, resistors, etc.... 

Never install inductive loads as neon, transformers, etc...
To connect the output, connect lamp/s or other load to the indicated terminal (see General Wiring Map). 
Once again, verify that input and output are correctly connected. Press the bush button and the circuit will be 
supplied connecting the output and activating the load. 

E L E C T R O N I C C I R C U I T S

 

All the module’s CEBEK have 

3 years of total warranty 

in thecnical 

repairing, and spares from the date of buy.

CEBEK is trade make of FADISEL S.L. more than 300 module’s are avaible in 
stock for any purpose 

request our CATALOGUE, 

or visit our Web.

 

Http://www.sakma.com/CEBEK

Y

S

E R

A

TECHNICAL SUPPORT AND INFORMATION.

For any questions or more information:

By Fax.

 (24h.) +34.3. 432.29.95

By Mail:

 C/ Quetzal, 17-21, Entlo. 2º (08014) BARCELONA - SPAIN.

By E-Mail: [email protected]
Keep you invoice. 

For any repairing could you send this with module. Else, the  module will lost the warranty.

 Power Supply Connection.

Power Supply Disconnection.

Timer turn on.

Timer turn off.

Activated Output

Desactivated Output

Activated Output

Desactivated Output

Activated Output

Desactivated Output

Отзывы: