background image

 

 

 

B. Factory default values 

 

  
Key-in keypad time: 10 seconds.  

Door release time: 1 second  
Programming time: 2 minutes 

 

5-digit Pin code and master code: 12345 

 
 

C. Audible signals 

 

1 short beep 

 

Press a digit keypad 

1 long beep 

 

Data validated in programming or access granted 

2 short beeps   

Entry or exit from programming 

4 short beeps   

Data computing error 

 

 

D. Visual signals 

 

 

LED colour 

 

 

Normal operating 

 

 

programming 

Flashing orange 

Stand-by 

Data computing error 

Orange  

 

Programming menu 

Green 

Access granted 

User number empty 

Red 

 

User number busy 

 

 

E. Consumption 

 

In stand-by: 4 mA  In use: 15 mA max 

 
 

II. PROGRAMMING 

 

A.

 

Time outputs 

 

Enter the master code twice (for the first use the master code default value is 12345). The orange LED 
lights and two beeps sound to confirm entry into programming mode. 

 

Press 

¿

0 then enter the ‘key in’ time in seconds: 10 for 10 seconds up to 99 for 99 seconds. The LED lights 

off during 1 second and a beep will sound to confirm that the time has been accepted. 

 
Press 

¿

1, then enter the door release time in seconds: 01 for 1 second up to 99 for 99 seconds. Enter 00 for 

a latched output. The LED lights off for 1 second and a beep will sound to confirm that the time has been 
accepted. 

 

Press # to exit from programming mode. 2 beeps confirm that unit is back to reading mode.  

  

4 beeps indicate a data computing error. 

 

 

B.

 

Code length  

 

Enter the master code twice (for the first use the master code default value is 12345). The orange LED and 
two beeps sound to confirm entry in the programming mode. 

 

Press 

¿

2 to program the code length then enter 3, 4, 5, 6, 7 or 8 The LED lights off for 1 second and a beep      

sound to confirm that the new code length has been accepted. 
 

IMPORTANT: When the code length has been modified, the Master code should be reprogrammed, in 
the new code format, also while in programming.  

Содержание PROMI E

Страница 1: ... A G R A M A M D I N S T R U C T I O N S PROMI E 100 Pin codes I PRESENTATION This device comes with a varistor The varistor must be connected to the strike terminal electromagnet operated by the device If this product works with many strikes each of them should have a varistor The varistor controls the overload produced by the strike coil emf If you are using a Shear Lock electromagnetic lock it ...

Страница 2: ...r the key in time in seconds 10 for 10 seconds up to 99 for 99 seconds The LED lights off during 1 second and a beep will sound to confirm that the time has been accepted Press 1 then enter the door release time in seconds 01 for 1 second up to 99 for 99 seconds Enter 00 for a latched output The LED lights off for 1 second and a beep will sound to confirm that the time has been accepted Press to e...

Страница 3: ...g mode Enter the user number 00 to 99 The LED lights off during 1 second and an audible beep sound If the LED is green enter the 3 4 5 6 7 or 8 digit Pin code The LED lights off during 1 second and an au dible beep is emitted The LED lights in orange to indicates that the new Pin code has been programmed If a pin code has already been programmed or is the same as the master code then 4 beeps are e...

Страница 4: ... to reset all the memory The red LED flashes during 5 seconds then stops flashing and becomes solid red during the rest of the reset The LED lights off Remove the jumper to go back to the stand by mode VI WIRING DIAGRAM ST1 on Reset ST1 off stand by mode PROMI E description 12 Input voltage 12V AC DC V Input voltage 12V AC DC T N O contact C Common R N C contact M Common PB B Request to exit input...

Страница 5: ...5 Do not forget to put the varistor on the lock User number Pin Codes User ...

Страница 6: ...6 20 5 105 120 135 23 24 15 38 61 75 5 Wiring access Area 30 x 40 ...