-5-
LOCK
Take off the Jumper
POWER
SUPPLY
L1
L2
PL
S1+
GND
Unlock parameter setting(set in monitor)
Door Lock Controlled with Dry Contact
Note:
4. Setup the
Unlock Mode
of Monitor for different
lock types.
00:10 DS-1
About
Local Address
00.00
Video Standard
AUTO
System Verson
00.01.00
Display Driver
1.0
Font
1.0
UI
1.0
INSTALLER SETUP
123
_
? + OK: Help Menu
@ + OK: Address Setting Menu
1.
An
external power supply must be used according
to the lock
power requirements
.
2. The in
ternal
relay contact is restricted to AC or
DC 24V/1A.
3. The jumper must be
removed
before connecting.
•
Power-on-to-unloc
k (Fail Secure)
type:
Unlock Mode=0 (by default)
•
Power-off-to-unlock
(Fail Safe)
type:
Unlock Mode=1
•
When the
About
page
shows
, press
UNLOCK
button on front panel and hold for 2
seconds.
•
On main menu page, touch
[Logo]
icon to enter
About
page.
•
A
QWERTY k
eypad is shown.
Refer to
the following:
Note:
1.
The CDV96KP m
ust
be
connect
ed
before setting.
2.
A set
parameter will be saved in
CDV96
KP automatically,
it only needs to be
set on one
monitor.