EN
EN
10
CDV-91S
2EASY 2-wire 1-button Video Door Station
Note: If no operations are completed for 10 seconds, the panel will exit the settings
mode automatically.
Initialisation
Press and hold
KEY_CALL
to activate initialisation
LED_UNLOCK: ON
LED_KEY: ON
Buzzer --> Beep+, Beep
After initialisation.
Exit settings automatically
LED_UNLOCK: ON
LED_KEY: ON
Set bit 6 to ON or connect power and within 10 secs, press and hold KEY_CALL to enter
the settings mode.
9] CABLE REQUIREMENTS
The maximum distance of the wiring is limited in the 2EASY system. Using different
cables may also affect the maximum distance which the system can reach.
Standard IN-OUT wiring
Cable and distance (unit: m)
Cable Usage
A
B
<2 IM
B
<16
IM
Belden 9470 UTP
2x0.75mm
2
60
100
40
Belden 8471 UTP
2x1mm
2
80
120
60
A
B
Recommended cable:
16AWG, Belden 8471