PERIODIC MAINTENANCE 

MAINTENANCE CHART

 

Item 

Remarks 

Pre-operation 

check 

(daily) 

Initial 

1 months 

or 20 Hr 

Every 

3 months 

or 50Hr 

Every 

6 months 
or 100Hr 

Every 

12 months 

or 300Hr 

Spark 
Plug 

Check condition adjust gap and 
clean. Replace if necessary. 

 

 

 

 

 

Engine 
Oil 

Check oil level 

 

 

 

 

 

Replace 

 

 

 

 

 

Air Filter 

Clean. Replace if necessary. 

 

 

 

 

 

Fuel Filter 

Clean fuel cock filter. Replace if 
necessary 

 

 

 

 

 

Choke   

Check choke operation 

 

 

 

 

 

Valve 
Clearance 

Check and adjust  when engine 
is cold. 

 

 

 

 

 

Fuel Line 

Check  fuel  hose  for  crack  or 
damage. Replace if necessary. 

 

 

 

 

 

Exhaust 
System 

Check for leakage. Retighten or 
replace gasket if necessary 

 

 

 

 

 

Check muffler screen. 
Clean / replace if necessary. 

 

 

 

 

 

Carburetor  Check choke operation 

 

 

 

 

 

Cooling 
system 

Check fan damage. 

 

 

 

 

 

Starting 
system 

Check recoil starter operation. 

 

 

 

 

 

Idle speed  Check and adjust engine idle speed 

 

 

 

 

 

Fittings / 
Fasteners 

Check  all  fittings  and  fasteners 
correct if necessary. 

 

 

 

 

 

Crankcase 
breather   

Check breather hose for cracks or 

damage. Replace if necessary 

 

 

 

 

 

Generator  Check the pilot light comes on 

 

 

 

 

 

Regular maintenance is most important for the best performance and safe operation. 

 

Содержание GS-6500IE

Страница 1: ...IMPORTANT Please make certain that persons who are to use this equipment thoroughly read and understand this user s manual prior to operation 2021 8 27 REV 01 ...

Страница 2: ...ow the instructions carefully In doing so you will ensure the safety of yourself and that of others around you andyoucanlookforwardtoyourpurchasegivingyoulongandsatisfactoryservice CONTENTS SAFETYINFORMATION 2 CONTROLFUNCTION 3 PRE OPERATIONCHECK 6 OPERATION 7 PERIODICMAINTENANCE 11 TROUBLESHOOTING 14 STORAGE 15 SPECIFICATION 16 WIRINGDIAGRAM 17 ...

Страница 3: ...erandchangeyourclothes When operating or transporting the machine be sure it is kept upright If it tilts fuel may leak from the carburetor or fueltank ENGINEANDMUFFLERMAYBEHOT Placethemachineinaplacewherepedestriansorchildrenarenotlikelytotouchthemachine Avoidplacinganyflammablematerialsneartheexhaustoutletduringoperation Keepthemachineatleast1m 3ft frombuildingsorotherequipment ortheenginemayover...

Страница 4: ...auge 7 Muffler 8 Battery 9 Airfilter 10 Brakelever 11 Wheel 12 Oilfillercap 13 Oildrainplug 14 Chokerod 15 Fuelcock 16 Engineswitch 17 ACprotector15A 18 Australiaindustrialsocket30A 19 Ground earth terminal 20 ACreceptacle15A 21 USBOutput 22 DC12Vreceptacle 23 DCprotector 24 Datadisplayinstrument 25 Outputreset 26 Economycontrolswitch 27 Remotecontrol 2 3 4 6 5 7 13 12 11 10 8 1 9 16 15 25 24 23 2...

Страница 5: ... ON the economy control unit control the engine speed according to the connected load The resultsarebetterfuelconnectionandlessnoise DCCIRCUITPROTECTOR The DC circuit protector turns off automatically when the load exceeds thegeneratorratedoutput CAUTION ReducetheloadtowithinspecifiedgeneratorratedoutputiftheDC circuitprotectorturnoff OUTPUT RESET Push reset button for continuous 2 seconds the gen...

Страница 6: ...uelfromthetanktothecarburetor DATADISPLAYINSTRUMENT Normal ShortCircuit OverCurrent Maintenance HighVoltofACoutputwithE1ACindicated HighVoltDCmotherlinewithE2DCindicated LowVoltofACoutputwithE1ACindicated LowVoltofDCmotherlinewithE2DCindicated MCUHighTemperaturewithE3indicated IGBTHighTemperaturewithE4indicated LowOilwithyellowlighton FAULT DefectsorOverloadswithredlighton OUTPUT NormalRunningwith...

Страница 7: ...ts into fuel Do notfill abovethe topofthefuel filter or it may overflow when the fuelheatsuplaterandexpands Wipeoffspiltfuelthoroughlybeforestartingengine Keepopenflamesaway CHECKENGINEOIL Make sure the engine oil is at the upper level of the oil filler hole Add oil asnecessary Removeoilfillercapandchecktheengineoillevel If oil level is below the lower level line refill with suitable oil to upper ...

Страница 8: ...allthecoverandtightenthescrew NOTE Recommendedbattery 12V18AH OPERATION NOTE Thegenerator has beenshipped withoutengineoil Fill withoil or it willnotstart Donottiltthegeneratorwhenaddingengineoil Thiscouldresultin overfillinganddamagetotheengine STARTINGTHEENGINE NOTE Beforestartingtheengine donotconnecttheelectricapparatus A Electricstart 1 TurnthefuelcocklevertotheONposition 2 Pulloutchokerodtot...

Страница 9: ...ure generator battery fullybecharged and at least charged eachtwomonths USINGELECTRICPOWER 1 ACAPPLICATION a ChecktheACpilotlampforpropervoltage b Turn off the switch es of the electrical appliance s before connectingtothegenerator c Inserttheplug s oftheelectricalappliance s intothereceptacle CAUTION Besuretheelectricapparatusisturnedoffbeforepluggingin Besurethetotalloadiswithingeneratorratedout...

Страница 10: ...reset button to restore the power supplyofthegenerator CAUTION ThegeneratorACoutputautomaticallyresetswhentheengineisstoppedandthenrestarted The overload indicator light may come on for a few seconds at first when using electric devices that require a large startingcurrent suchasacompressororasubmergiblepump However thisisnotamalfunction 3 DCAPPLICATION option Thisusageisapplicableto12Vbatterychar...

Страница 11: ...histurnedoffwhilechargingthebattery STOPPINGTHEENGINE 1 Turn off the power switch of the electricapparatus or disconnect any electricdevices 2 TurntheengineswitchtoSTOPposition Clickremoteswitchtothe position 3 TurnthefuelcocklevertoOFF CAUTION PlacetheengineswitchintheSTOPpositionifthegeneratorsetis notusedforalongtime IfitisplacedintheRUNposition theremotecontrolmoduleisin thestateofreceivingsig...

Страница 12: ... and adjust when engine iscold FuelLine Check fuel hose for crack or damage Replaceifnecessary Exhaust System Check for leakage Retighten or replacegasketifnecessary Checkmufflerscreen Clean replaceifnecessary Carburetor Checkchokeoperation Cooling system Checkfandamage Starting system Checkrecoilstarteroperation Idlespeed Checkandadjustengineidlespeed Fittings Fasteners Check all fittings and fas...

Страница 13: ...foreignmaterialentersthecrankcase Donottiltthegenerator whenaddingengineoil Thiscouldresultin overfillinganddamagetotheengine Cleantheoilfiltereveryother100hr AIRFILTER Maintaining an air cleaner in proper condition is very important Dirt induced through improperly installed improperly serviced or inadequate elements damages and wears out engines Keep the element always clean 1 Removethecover 2 Re...

Страница 14: ...fueltankcapandfilter 2 Cleanthefilterwithsolvent Ifdamaged replace 3 Wipethefilterandinsertit WARNING Besurethetankcapistightenedsecurely MUFFLERSCREEN WARNING The engine and muffler will be very hot after the engine has been run Avoid touching the engine and muffler while they are still hot with anypartofyourbodyorclothingduringinspectionorrepair 1 Removethecover 2 Removethemufflerscreen Standard...

Страница 15: ... Supplyfuel Fuelintank FueltankcapairventknobtoON fuelcockknobtoON Cloggedfuelline Cleanfuelline cloggedcarburetor Cleancarburetor 2 Engineoilsystem Insufficient Oillevelislow Addengineoil 3 Electricalsystems Poorspark Sparkplugdirtywithcarbonorwet Removecarbonorwipesparkplugdry Faultyignitionsystem Consultdealer 4 Compressioninsufficient Wornoutpistonandcylinder Consultdealer Generatorwon tproduc...

Страница 16: ...NGINE 1 Remove the spark plug pour in about one tablespoon of SAE 10W30 or 20W40 motor oil into the spark plug hole andreinstallthesparkplug 2 Usetherecoilstartertoturntheengineoverseveraltimes withignitionoff 3 pulltherecoilstarteruntilyoufeelcompression 4 Stoppulling 5 Cleanexteriorofthegeneratorandapplyarustinhibitor 6 Storethegeneratorinadry well ventilatedplace withthecoverplaceoverit 7 Thege...

Страница 17: ...8 64 Displacement 389cc Max Output 7 5kW 3600rpm Fuel RegularAutomobileGasoline FueltankCapacity 18 5liters RatedContinuousOperation 4h30min 100 Load Lubricatingoil SAE10W30 LubricatingoilCapacity 1 1liter StartingSystem ElectricStarter Remotestarter Ignitionsystem C D I SparkPlug Type F6RTC DIMENSION Netdimension L W H 750 537 630 Overalldimension L W H 800 590 670 NetWeight 89kg DryWeight 101kg ...

Страница 18: ... BLOCK ELE VALVE ELECTRIC MAGNET ELECTRIC LOCK GROUND TERMINAL BL Bu BL W W G IGNITION CONTROLLER ECON SWITCH STEPPER MOTOR ASSY GRAY BLACK WHITE PI Gr PINK BL W ORANGE YELLOW O Y BL Bu BLACK BLUE BROWN RED Br R W WHITE G GREEN P PURPLE W BL P W IGNITION COIL BL O R Y G R BL P W Gr R BL Bu BL FUSE 5A O Y W R BL O R Y W BL Bu R W REMOTE UNIT RECTIFIER DC 12V OUTPUT Bu Bu Bu Bu Bu BL FUSE 15A R DC P...

Отзывы: