7
. PROBLEMS AND MAINTENANCE
7
.1
Cleaning
It is raccomended to clean the instrument only with a cloth
welted with water or with a detergent neither abrasive nor
containing solvents.
7
.2
Disposal
The appliance (or the product) must be
disposed of separately in compliance
with the local standards in force on
waste disposal.
8
. WARRANTY AND REPAIRS
The instrument is under warranty against construction vices
or defected material, noticed within 18 months from delivery
date. The warranty is limited to the repairs or to the substitu-
tion of the instrument. The eventual opening of the housing,
the violation of the instrument or the wrong use and installa-
tion of the product means the automatic decay of the warranty.
In case of defected instrument, noticed in warranty period or
out of warranty, do contact our sales department to obtain
the shipment authorisation.
The defected product must be shipped to
Elettromeccanica CDC
with the detailed description of the failures found and without any
fees or charge for
Elettromeccanica CDC
, safe different
agreements.
9
. TECHNICAL DATA
9
.1 Electrical data
Power supply:
12 VAC/VDC, 24 VAC/VDC,
100 ÷ 240 VAC ±10%;
AC frequency:
50/60 Hz;
Power consumption:
About 3 VA;
Inputs: 2
free of voltage
digital inputs
;
Outputs:
Up to
2 relay outputs
or
12 VDC/15 mA for SSR
drive
:
EN 61810
EN 60730
UL 60730
Out1
- SPDT - 16A -
1HP 250V,
1/2HP 125 VAC
16 (9) A
10 (4) A
12 A Res.,
30 LRA,
5 FLA
Out2
- SPST-NO - 5A -
1/10HP 125/250V
5 (1) A
2 (1) A
2 A Gen. Use
12 A max. for those with removable terminal model;
Relay output Electrical life:
100000 operations;
Overvoltage category:
II;
Protection class:
Class II;
Insulation:
Reinforced insulation between low voltage parts
(H or L type power supply and relay outputs) and front panel;
Reinforced insulation between low voltage parts (H or L type
power supply and outputs if both are relays) and the extra
low voltage parts (inputs); Reinforced insulation between
power supply and relay outputs; Basic insulation between
relay outputs and between relay and SSR drive output; Basic
insulation between H or L type power supply and inputs
when a relay + SSR drive output combination is present; No
insulation between type F power supply terminals and input.
9
.2 Mechanical characteristics
Housing:
Self-extinguishing plastic, UL 94 V0;
Heat and fire resistance category:
D;
Ball Pressure Test as described in EN60730:
accessible
parts 75°C; support live parts 125°C;
Dimensions:
78 x 35 mm, depth 64 mm;
Weight:
About 125 g;
Mounting:
Incorporated flush in panel (thickness max. 12/29
mm) in a 71 x 29 mm hole;
Connections:
Inputs:
Fixed or removable screw terminal block for
0.2 ÷ 2.5 mm2/AWG 24 ÷ 14 cables;
Power supply:
Fixed or removable screw terminal block
or Faston 6.3 mm for 0.2 ÷ 2.5 mm2/AWG 24 ÷ 14 cables;
Protection degree:
IP65 mounted with screw type bracket
(optional);
Pollution degree:
2;
Operating temperature:
0 ÷ 50°C;
Operating humidity:
< 95 RH% with no condensation;
Storage temperature:
-25 ÷ +60°C.
9
.3 Functional features
Time range:
4 programmable timing scales:
9999
h,
99
h
59
min,
99
min
59
s,
99
s
99
hundreds of second;
Display resolution:
Based on the time scale used:
hours,
minutes,
seconds,
hundreds of second;
Overall accuracy:
±0.1 fs;
Input delay:
15 ms max.;
Display:
4 Digit Red (Blue optional), height 12 mm;
Compliance:
Directive LV 2014/35/EU
(EN 60730-1, EN 60730-2-7,
EN61812-1, UL 508);
Directive EMC 2014/30/EU
(EN55011: class B;
EN61000-4-2: 8 kV air, 4 kV cont.; EN61000-4-3: 10V/m;
EN61000-4-4: 2 kV supply and relay outputs, 1 kV inputs;
EN61000-4-5: supply 2 kV com. mode, 1 kV\diff. mode;
EN61000-4-6: 3V).
ELETTROMECCANICA CDC S.r.l - TX40
- MANUAL rev.2 - PAG.
10