. PROBLEMS AND MAINTENANCE

7

.1 

Cleaning

It is raccomended to clean the instrument only with a cloth 
welted with water or with a detergent neither abrasive nor 
containing solvents.

7

.2 

Disposal

The appliance (or the product) must be 
disposed of separately in compliance 
with the local standards in force on 
waste disposal.

8

. WARRANTY AND REPAIRS

The instrument is under warranty against construction vices 
or defected material, noticed within 18 months from delivery 
date.  The warranty is limited to the repairs or to the substitu-
tion of the instrument.  The eventual opening of the housing, 
the violation of the instrument or the wrong use and installa-
tion of the product means the automatic decay of the warranty.

 

In case of defected instrument, noticed in warranty period  or 
out of warranty, do contact our sales department to obtain 
the shipment authorisation.
The defected product must be shipped to 

Elettromeccanica CDC

 

with the detailed description of the failures found and without any 
fees or charge for 

Elettromeccanica CDC

, safe different 

agreements.

9

.  TECHNICAL DATA

9

.1  Electrical data

Power supply:

 12 VAC/VDC, 24 VAC/VDC,  

100 ÷ 240 VAC ±10%;

AC frequency:

 50/60 Hz;

Power consumption:

 About 3 VA;

Inputs: 2 

free of voltage 

digital inputs

;

Outputs:

 Up to 

2 relay outputs

 or 

12 VDC/15 mA for SSR 

drive

:

EN 61810

EN 60730

UL 60730

Out1

 - SPDT - 16A - 

1HP 250V,  
1/2HP 125 VAC

16 (9) A

10 (4) A

12 A Res., 
30 LRA, 
5 FLA

Out2

 - SPST-NO - 5A - 

1/10HP 125/250V

5 (1) A

2 (1) A

2 A Gen. Use

12 A max. for those with removable terminal model;

Relay output Electrical life:

 100000 operations;

Overvoltage category:

 II;

Protection class:

 Class II;

Insulation:

 Reinforced insulation between low voltage parts 

(H or L type power supply and relay outputs) and front panel; 
Reinforced insulation between low voltage parts (H or L type 
power supply and outputs if both are relays) and the extra 
low voltage parts (inputs); Reinforced insulation between 
power supply and relay outputs; Basic insulation between 
relay outputs and between relay and SSR drive output; Basic 
insulation between H or L type power supply and inputs 
when a relay + SSR drive output combination is present; No 
insulation between type F power supply terminals and input.

9

.2  Mechanical characteristics

Housing:

 Self-extinguishing plastic, UL 94 V0;

Heat and fire resistance category:

 D;

Ball Pressure Test as described in EN60730:

 accessible 

parts 75°C; support live parts 125°C;

Dimensions:

 78 x 35 mm, depth 64 mm;

Weight:

 About 125 g;

Mounting: 

Incorporated flush in panel (thickness max. 12/29 

mm) in a 71 x 29 mm hole;

Connections:

Inputs: 

Fixed or removable screw terminal block for  

0.2 ÷ 2.5 mm2/AWG 24 ÷ 14 cables;

 

Power supply: 

Fixed or removable screw terminal block 

or Faston 6.3 mm for 0.2 ÷ 2.5 mm2/AWG 24 ÷ 14 cables;

Protection degree:

 IP65 mounted with screw type bracket 

(optional);

Pollution degree:

 2;

Operating temperature:

 0 ÷ 50°C;

Operating humidity: 

< 95 RH% with no condensation;

Storage temperature:

 -25 ÷ +60°C.

9

.3  Functional features

Time range:

 4 programmable timing scales: 

9999

 h,

99

 h 

59

 min,

99

 min 

59

 s,

99

 s 

99

 hundreds of second;

Display resolution:

 Based on the time scale used: 

hours,
minutes,
seconds,
hundreds of second;

Overall accuracy:

 ±0.1 fs;

Input delay:

 15 ms max.;

Display:

 4 Digit Red (Blue optional), height 12 mm;

Compliance:

Directive LV 2014/35/EU

 (EN 60730-1, EN 60730-2-7, 

EN61812-1, UL 508); 

Directive EMC 2014/30/EU

 (EN55011: class B; 

EN61000-4-2: 8 kV air, 4 kV cont.; EN61000-4-3: 10V/m; 
EN61000-4-4: 2 kV supply and relay outputs, 1 kV inputs; 
EN61000-4-5: supply 2 kV com. mode, 1 kV\diff. mode; 
EN61000-4-6: 3V).

ELETTROMECCANICA CDC S.r.l - TX40

 

- MANUAL rev.2 - PAG.

10

Содержание TX40

Страница 1: ...r external buzzer for signaling the end of the count The 4 digits display normally shows the counting status while the outputs status is signalled by 2 LEDs The instru ment has also 2 digital inputs for voltage free contacts that can be used for the count enabling CNT EN and Reset RES commands and can have up to 2 relay outputs or SSR for driving Solid State Relays The instrument is programmed by ...

Страница 2: ... short key if pressed and released the key has no effect 1 Only s t1 Set Time value can be set with this procedure 2 Only s t2 Set Time value can be set with this procedure 3 s t1 and s t2 Set Times can be set with this procedure 4 Only s t3 Set Time value can be set with this procedure 5 s t1 and s t3 Set Times can be set with this procedure 6 s t2 and s t3 Set Times can be set with this procedur...

Страница 3: ... without password unprotected To change the parameter visibility press the key and keeping it pressed press also the button The SET LED changes its state indicating the new level of parameter accessibility ON Not protected Flashing Password protected In case some parameters are set as Not protected access ing the programming mode the display first shows the Not protected parameters then the r p pa...

Страница 4: ...To obtain the declared protection degree IP65 use screw type bracket optional Avoid placing the instrument in dirty environments or with very high humidity levels that may create condensation and avoid the introduction of conductive substances into the instrument Ensure adequate ventilation to the instrument and avoid installation in containers that house devices which may overheat or which may ca...

Страница 5: ...fore the end steady on Count ended Reset status off After Reset display shows 0000 when counting mode is UP F Cnt uP or Set time value if the count mode is DOWN F Cnt dn While counting display shows the time that elapses increas ing if F Cnt uP or decreasing if F Cnt dn For functions that require a cycle end F o1t 1 2 at the end of the count the display flashes 0000 if F Cnt dn or the Set time val...

Страница 6: ...Ft is different from oF only acts as a Reset CNT Count RESET 0 1 2 3 i fct 4 Reset Start Reset Start Stop 0 1 2 3 0 1 2 3 0 Stop Reset i Fct 5 Bistable Reset Start Stop At 1st CNT impulse the timer is reset at the 2nd the count starts at the 3rd impulse the count stops disabling the output if active and so on In this mode the front Start Stop button if t UFt 2 acts in exactly the same way as the C...

Страница 7: ...in 5 different modes with F o2t parameter Se si desidera utilizzare OUT2 è possibile stabilirne il funzi onamento tramite il parametro F o2t secondo 5 diversi modi F o2t oF OUT2 Output disabled F o2t 1 OUT2 works like OUT1 OUT2 output operates exactly like OUT1 output in order to have a double output contact F o2t 2 OUT2 output works as an instant contact ON during count OUT2 is activated during t...

Страница 8: ...peration The internal buzzer can be programmed using the F buF parameter to operate in the following ways oF Internal buzzer disabled 1 Activated at end of S t1 time for S t2 period sound also when keys are pressed If Reset command is given with key or digital input the buzzer is silenced immediately This mode is only active for operations that normally do not involve the use of the S t2 time this...

Страница 9: ...tput operating mode oF No function 1 Out2 operates as Out1 2 Instantaneous Contact Output ON during count 3 Out2 operates as Out1 but with absolute Set time s t3 4 Out2 operates as Out1 but with relative Set time s t3 in advance 5 Out2 operates as the buzzer oF 13 F Cnt Count mode uP UP dn DOWN uP 14 F buF Buzzer operating mode oF Disable 1 Sounds at end of the cycle for the s t2 period key pressu...

Страница 10: ...er supply and relay outputs and front panel Reinforced insulation between low voltage parts H or L type power supply and outputs if both are relays and the extra low voltage parts inputs Reinforced insulation between power supply and relay outputs Basic insulation between relay outputs and between relay and SSR drive output Basic insulation between H or L type power supply and inputs when a relay ...

Страница 11: ...Codice d ordine T X 4 0 H I R R 1 0 Y Y P ZZ Relè Relay R Statica Static S YY OLP 3RZHU 9DF GF OLP 3RZHU 9DF H Morsettiera estraibile Removable screw terminal M Faston Faston F 0 I Terminali a vite Screw terminal Buzzer With buzzer B No buzzer Not buzzer 0 ...

Отзывы: