background image

MON-7HD 

IP

 C

amera

 T

ester

 / HD CCTV Test Monitor 

User

 

Manual

V01.00

Supplied exclusively by CCTV Camera Pros

www.cctvcamerapros.com

Содержание MON-7HD

Страница 1: ...MON 7HD IP Camera Tester HD CCTV Test Monitor User Manual V01 00 Supplied exclusively by CCTV Camera Pros www cctvcamerapros com...

Страница 2: ...ead the Safety Information carefully in the manual The manual should be kept well in case of reference Keep the S N label for after sale service within warranty period Product without S N label will b...

Страница 3: ...camera connection 9 3 2 3 HD Coaxial camera connection 10 3 2 4 HDMI IN 11 3 3 OSD menu 11 3 3 1 Lite mode Normal mode 11 3 3 2 Drop down Menu 15 3 3 3 Short cut menu 16 3 3 4 Screen capture 17 3 3 5...

Страница 4: ...9 PoE power DC12V 2A and DC 5V 2A USB power output 73 3 3 20 Cable Test 74 3 3 21 RJ45 cable TDR test 75 3 3 22 Cable Tracer Optional 77 3 3 23 TDR cable test Optional 79 3 3 24 PoE Voltage test 82 3...

Страница 5: ...ing 108 3 3 42 File explorer 113 3 3 43 Theme 114 3 4 Audio test 117 3 5 HDMI output 117 3 6 PoE power output 117 3 7 DC12V 2A power output 118 4 Specifications 120 4 1 General Specifications 120 4 2...

Страница 6: ...able gas Do not disassemble the instrument since no component inside can be repaired by the user If the disassembly is necessary indeed please contact with the technician of our company The instrument...

Страница 7: ...SDI EX SDI cameras as well as testing 4K H 264 4K H 265 camera via mainstream The 1280x800 resolution enables it to display network HD cameras and analog cameras in high resolution The unit supports m...

Страница 8: ...7 4V DC 5000mAh 5 BNC cable 6 RS485 cable 7 SC ST connector Only for optical power meter 8 Multi meter test leads one pair of red and black only for the Multi meter models 9 Output Power cable 10 Aud...

Страница 9: ...Page 4 2 5 Function interface...

Страница 10: ...ward 11 Rightward select the parameter whose value will be changed Add the value of the parameter Pan the PTZ right 12 Downward set function or reduce the value of the parameter Tilt the PTZ downward...

Страница 11: ...2V2A power output for provisional DC power supply 23 HDMI IN Optional 24 CVBS IN AHD TVI CVI Coaxial interface BNC interface AHD TVI CVI Optional 25 Video signal output BNC interface cable tracer inte...

Страница 12: ...on polymer rechargeable battery The battery cable inside battery cabin should be disconnected for safety during transportation Prior to the use of the instrument the battery cables inside the battery...

Страница 13: ...nings Not allow insert multi meter pen in the current terminal to measure voltage 3 2 Instrument connection 3 2 1 IP camera connection Power an IP camera with an independent power supply then connect...

Страница 14: ...he PoE switch and the power sourcing equipment are allowed to connect to the tester s PSE port and the PoE power will be supplied to the IP camera by the tester s LAN port On this condition the tester...

Страница 15: ...er RS485 interface Note positive and negative connection of the cable 3 2 3 HD Coaxial camera connection SDI CVI TVI AHD camera are classified as HD coaxial cameras Hereby the following instruction of...

Страница 16: ...3 OSD menu Press the key 2 seconds to turn on Press the key again to turn off short press the key to enter sleep mode press it again to test If tester works abnormally and cannot be turned off Press t...

Страница 17: ...eral seconds can move the icon to other apps In lite mode click the finger icon in the lower right corner to release lock icon move icons and change function icons sequence Normal mode Tap the screen...

Страница 18: ...ess icon several seconds go screen management status Change icons sequence and move it to common tools bar You can move the icon to any pages self define the number of icons in any page Make interface...

Страница 19: ...name Icon will be auto placed in the new named folder Press the folder several seconds to change the folder name you can move the icon out of folder the folder will be auto deleted until move out all...

Страница 20: ...icon CVBS to enter you can test IP and analog camera at the same time Video OUT Click Video OUT to enter floating window connecting the BNC cable to tester and appears analog video monitor interface i...

Страница 21: ...you can turn on it and switch functions then press to enter app tap other area on the screen to exit the menu Short cut menu setting you can long press any app in the all applications list it will au...

Страница 22: ...bile screen projection Only for android version The meter creates WIFI hotspot connect mobile phone to the tester s WIFI hotspot or the tester and mobile phone connect to the same Wi fi network Tap ic...

Страница 23: ...projection Install VLC player in the PC turn on the VLC player Media Open Network Streaming and input the RTSP address of on the top instrument two dimensional code click play to view the screen real...

Страница 24: ...Page 19 3 3 6 Rapid video Press enter function one key to detect all network cameras and auto play the images Auto log in and display camera image Detailed operation refer to ONVIF function...

Страница 25: ...ress IP discovery tester auto scan the whole network segment IP as well as auto modify the tester s IP to the same network segment with the scanned camera s IP Local IP Tester s IP address Tester can...

Страница 26: ...tart can PING camera s IP Rapid ONVIF Rapid ONVIF Quick link IPC TEST IPC TEST Quick link Applicability Using IP discovery app you don t need to know the first two digits of camera s IP address it can...

Страница 27: ...mera name and IP address on the Device List Tester can auto login camera and display camera image Click the button Refresh tester will scan the ONVIF camera again Click the newly displayed ONVIF camer...

Страница 28: ...Page 23 Enter a new password for the camera When comes out activate success prompt click login to display camera image...

Страница 29: ...work segments to scan camera s IP Auto Login After open this function tester can auto login camera and display camera image The login password is the same with last time the first time using password...

Страница 30: ...tools Snapshot Record Photo Playback PTZ and Settings ONVIF PTZ control Tap the image in the direction you want the PTZ camera to move Tap the left side of the image to move left right to go right up...

Страница 31: ...Page 26 IP camera video settings Click Video Set to enter the IP camera s encoder and resolution settings Make the desired changes and click OK to save...

Страница 32: ...ging Set to adjust image brightness saturation contrast sharpness and backlight compensation mode Profiles Click profiles can view video streaming current configuration files as well as switch between...

Страница 33: ...Page 28 Preview pictures Quickly preview and zoom in or out pictures automatically and manual refresh Identification click Identification to view information of the camera...

Страница 34: ...Page 29 Time set click Time set Select Manual set to set up the time of camera Maintenance For camera software reset or restore to factory settings...

Страница 35: ...et to change the IP address Some cameras cannot support change IP address so there is no change after saving Zoom in image press the key to enter the zoom mode Press it again to exit zoom mode When th...

Страница 36: ...the tester as the tester supports resolution up to 1080p the input image will be very clear after it is enlarged This is greatly helpful for the installers to ensure the IP camera s video coverage and...

Страница 37: ...rage the tester auto stores the files after snapshot Record When you click bottom the Record icon video starts recording A red recording icon appears on the screen and begins to flash and a timer appe...

Страница 38: ...rs Video files can play in the Video player on the main menu PTZ Set preset position Move the camera to preset position enter the preset number on the Bottom right corner to complete position preset C...

Страница 39: ...PTZ Speed set Horizontal and Vertical Speed set RTSP Get RTSP address of the current camera Doc Auto generate test reports document of camera click generate document Click Preview to view the report d...

Страница 40: ...ter the camera test information click Generate Document to complete the report Click Doc menu again you can preview the report document Icons description the description of function icons on the botto...

Страница 41: ...nterface Local IP This is the tester s IP address Click Edit to enter IP setting and change the tester s IP address settings IP camera type Click on the IP Camera type to select the Manufacturer and m...

Страница 42: ...il please witch to manually selecting IP Camera s IP Enter the IP camera s IP address manually or click Search to auto scan for the IP camera s IP address It is better to directly connect the IP camer...

Страница 43: ...o IP camera test interface Once you are viewing video on the IPC Test app you will see the Video Menu icon on the top right This button will give you access to Snapshot Record Photo Playback PTZ and S...

Страница 44: ...a picture and save the current video frame in the SD card as JPEG file If the unit is set to the manual mode an Input Name pop up box will appear and you can enter a title for the snapshot If the uni...

Страница 45: ...al storage before recording begins appears dialog box Input Name user defined the files name by Chinese character English letter or digit to store in SD card tester will hereby store the files in SD c...

Страница 46: ...mage click and hold on the file until this screen below appears Click to close and return to PTZ controller 4 Recorded video playback Click the Playback icon to view your recorded videos Tap on the vi...

Страница 47: ...en appears Video files also can play in the main menu Video Player 3 3 11 Video monitor test Analog camera test and PTZ control click icon to enter Display the input video image click the top menu bar...

Страница 48: ...row keys to move the yellow cursor to the protocol set corresponding Protocol and support more than thirty PTZ protocols Such as Pelco D Samsung Yaan LiLin CSR600 Panasonic Sony EVI etc B Port Click a...

Страница 49: ...k and set the protocols address interface and baud all must be consistent with the dome camera then the IPC tester can test After setting the parameter the tester can control the PTZ and lens To contr...

Страница 50: ...nual storage When select manual storage user can name and store the files 3 4 x zoom image display and Video out When image input press to enter zoom press it again to quit Using the touch screen to c...

Страница 51: ...ual mode an Input Name pop up box will appear and you can enter a title for the snapshot If the unit is set up to automatically set file names this box will not pop up 5 Video record When you click th...

Страница 52: ...47 6 Photo Click the icon photo to enter click the selected thumbnail photo to display it on the screen Double tap the image you want to view to make it full screen Double click again the photo to re...

Страница 53: ...mage click and hold on the file until this screen below appears Click to close and return to PTZ controller 7 Recorded video playback Click the Playback icon to view your recorded videos Tap on the vi...

Страница 54: ...ter Click the icon to enter the IP camera tester has adopted hardware high speed sampling and processing technology can perform both NTSC and PAL video amplitude signal measurements for PEAK to PEAK S...

Страница 55: ...TSC format the SYNC level is 40 5IRE For PAL format the SYNC level is 300 35mV If the level is too low it will cause the image to not frame out properly If the level is too high it will lead to a poor...

Страница 56: ...receiver and video cable connect one end to the tester VIDEO OUT port and the other end connected to VIDEO IN port the signal send via VIDEO OUT port and received via VIDEO IN port If the testing is...

Страница 57: ...bar by its BNC output to the monitor at the monitoring center If the monitor receive the color bar it means the video transmit channel works normally Meanwhile on the basis of the received color bar...

Страница 58: ...x1080P 25Hz 1920x1080P 30Hz 1920x1080I 50Hz 1920x1080I 60Hz IPC tester s HDMI output port can be use as SDI to HDMI converter output HD SDI image to HD TV monitor Select relative function on the right...

Страница 59: ...VI signal input the tester will display the image resolution on the top bar Double taps on the screen to make the image displayed full screen The tester supports resolution as follows 1280x720P 25FPS...

Страница 60: ...ntrol Enter PTZ address to perform parameters setting Operation instructions please refer to 3 3 1 PTZ 1 Video monitor test The PTZ address in the tester must be consistent with the dome camera or dec...

Страница 61: ...oom in and out the PTZ To control PTZ by key buttons Press arrow keys to control to control the PTZ direction of rotation Press the key to switch on or turn off the aperture Press the key adjust the f...

Страница 62: ...Page 57 Call preset position Tap the preset position Tap the preset position area input preset position number Tap call position to complete call preset position...

Страница 63: ...PTZ control parameters setting 2 Coaxial camera menu setting Tap icon UTC select menu setting to enter the dome camera menu Input calling dome camera menu address code after finishing the parameter s...

Страница 64: ...Page 59 Press arrow keys to set 3 Snapshot record photo viewer and video play back please refer to 3 3 1 PTZ 1 Video monitor test...

Страница 65: ...enu or press the key to close camera menu 4 Save setting Click icon Set on the right toolbar to enter storage setting Support auto storage and manual storage When select manual storage user can name a...

Страница 66: ...nal input the tester will display the image resolution on the top bar Double taps on the screen to make the image displayed full screen The tester supports resolution as follows 1280x720P 25FPS 1280x7...

Страница 67: ...nput calling dome camera menu address code after finishing the parameter settings you can press the key or click the icon to call the dome camera menu More operation instructions such as PTZ control c...

Страница 68: ...icon to enter When AHD signal input the tester will display the image resolution on the top bar Double taps on the screen to make the image displayed full screen The tester supports resolution as fol...

Страница 69: ...s setting is needed More operation instructions please refer to 3 3 6 CVI camera test 3 3 17 Network tool 1 IP address scan Connect the cable to the LAN port click icon to enter Set your IP address se...

Страница 70: ...say Destination host unreachable or have 100 packet loss If the tester connects to the device the send and receive packets will have a 0 packet loss Application PING testing is the most conventional...

Страница 71: ...ent a Start the server Click Start Server button to use the tester as a Server It will display its IP address at the top of the screen b Start send packet test Using the other IP tester type in the Se...

Страница 72: ...r as a test Client or Server to do the mutual testing with the tester If use computer as the server the computer IP address is 192 168 0 39 Tester as Client tester s IP address is 192 168 0 238 The Se...

Страница 73: ...Page 68 Or use tester as a Server computer as test Client select Client input tester s IP address to test When use tester as Server shows results...

Страница 74: ...LAN port of the switch flash If the tester and PoE switch are connected well the LAN port of POE switch flash at special frequency If not no any changes on the LAN port Application The tester will se...

Страница 75: ...s Click Save to start assigning dynamic IP addresses for IP cameras and other networked devices Click the Refresh button to check your Client list 6 Trace route It is used to determine path of the IP...

Страница 76: ...ess conflicts Click Add and enter the desired IP address To test different network segments click the Settings icon on the main menu and go to IP Settings and make the desired changes Once the desired...

Страница 77: ...therwise it will cause IP conflicts and stop the equipment normal working Link monitor can check if the new setting IP address is occupied 3 3 18 Rapid IP Discovery Connect the cable to tester s Lan p...

Страница 78: ...screen when the POE power is still on Note 1 Don t input power into the DC12 2A OUTPUT port 2 Don t output this DC12V 2A power to the DC12V IN port of the IP camera tester to avoid destroy 3 The IPC...

Страница 79: ...sequence of wires as well as the serial number of the cable tester kit will be displayed The number of the cable tester is 255 If need several different number other types cable testers should pay the...

Страница 80: ...nline if not link up or open circuit screen display open circuit if cable pair is short circuit screen display short circuit Length the max test length is 180 meters when cable is open circuit or shor...

Страница 81: ...link up if reflectivity value is 0 it is the best quality communication Impedance after link up if the impedance value is 100 it is the best quality communication the range is generally in 85 135 Ske...

Страница 82: ...gram the cable sequence display for reference Click Help check the instruction of all parameters 3 3 22 Cable Tracer Optional Connect test cable or BNC cable to the UTP port or the CABLE SCAN VIDEO OU...

Страница 83: ...audio signal from the tester it may be induced into adjacent or crossing cables however the cable that makes the loudest noise is the one that s connected to the meter Application It s convenient for...

Страница 84: ...r Connect Alligator clip cable to the TDR port and the cable must connect well before testing otherwise it will influence the accuracy Click to enter and click Start to test Built in BNC cable network...

Страница 85: ...ined 1 for calibration 11 groups user defined can be set 1 Select user defined and click Calibration to enter test click user defined 1 can define cable name such as AiPu BNC 5 2 Click Cable Type to s...

Страница 86: ...use of pulse reflection method to transmit pulse signal for tested cable when cable is open circuit or short circuit reflected pulse is generated the tester receives and deals with the reflected wave...

Страница 87: ...screen Note This test if for measuring the voltage being drawn by the PoE node and the IP tester must be between the PoE switch and the PoE node for this test to work Note The PoE switch must be conn...

Страница 88: ...on PoE to enter voltage measurement app screen show the current adaptor input voltage and power Note the current 12V input measured power is the battery charging power and the device working power the...

Страница 89: ...Measuring AC DC Voltage and current measurement state display Auto range The Multimeter auto adjust the range by input signal or tested components Data hold Hold data Relative measurement Display the...

Страница 90: ...lead to the COM jack and the red test lead to the V jack b select U enter the AC voltage measurement C the tester default Auto range status by click AC auto range d Manual range can be select press th...

Страница 91: ...al range c Manual range 0 000mA 6 6mA range 00 00mA 66 00mA range 000 0mA 660 0mA range 00 00A 10 00A range use 10A socket d Select the range to enter current measurement NOTE When only the figure OL...

Страница 92: ...600mA range 00 00mA 66 00mA range 000 0mA 660 0mA range 00 00A 10 00A range use 10A socket Note When only the figure OL is displayed it indicates over range situation and the higher range has to be s...

Страница 93: ...K 66 00K range 000 0 K 660 0K range 0 000 M 6 600M range 00 00 M 66 00M range F Continuity Testing a Connect the black test lead to the COM jack and the red test lead to the V jack b to select enter t...

Страница 94: ...nish the testing quickly without view the screen H Capacitance Measuring a Connect the black test lead to the COM jack and the red test lead to the V jack b Select to enter enter the capacitance measu...

Страница 95: ...ately should not test in the installation of circuit b To avoid electric shock be sure the capacitors have been discharged fully before measuring the ca pacitance of a capacitor c While testing the ca...

Страница 96: ...d limit time work If input voltage over 600V will damage the meter mA current fuse range 250V 1A if the current over the rated range fuse will melt to protect the meter Pls use the same model when cha...

Страница 97: ...ile testing set the wavelength for measurement Click relative difference to test the tester Auto save current fiber power value as the base reference value Input another optical fiber to be measured t...

Страница 98: ...can select Steady mode Evasive 1Hz Evasive 2Hz and Time off Click button Steady mode to enter steady status click button Evasive 1Hz and Evasive 2Hz to enter pulse mode click button Time off VFL is t...

Страница 99: ...4 Click Steady mode red laser source emits steady click again to quit Click icons Evasive 1Hz or Evasive 2Hz to enter pulse mode the red laser source is emitted by a certain frequency press it again t...

Страница 100: ...ard send the code to the tester if it can be read the protocol will shown on the upper right like Pelco D if not like P While the tester receives the code press the key to empty Though the RS485 port...

Страница 101: ...video formats of MP4 H 264 MPEG4 and MKV The IP tester recorded files can play directly via the Media player The Media player will automatically display the video files from the SD card Click on the d...

Страница 102: ...e to view your camera via the ONVIF or IPC Test apps it is possible your camera will have an RTSP stream and you can view live video From the main menu select the APP Tool folder and then select the R...

Страница 103: ...nt the ip tester does not auto detect the rtsp stream refer to the specific camera manufacturer for the specific rtsp stream url you may find this on line with a search of the camera model number and...

Страница 104: ...activate now 2 Input password Input new password tap ok to activate 3 Confirm activation After activating the camera the program default modifies the camera IP Activated multiple cameras in the local...

Страница 105: ...Page 100 Play display image from the camera Modify network information Change the camera IP address subnet mask and gateway etc Modify user information Modify the camera s user name and password...

Страница 106: ...ahua test tool Dahua test tool is developed for installation and debugging of the Dahua IP camera it can display image and modify IP user name and password etc Making Dahua camera test more convenient...

Страница 107: ...102 Select the camera of the online detection menu if the camera support non verification login you can click play directly and view the image Pop up stream menu select mainstream or second stream to...

Страница 108: ...ine detection menu and input correct user name and password then click log in After logging successful you can test it Play select mainstream or seconded stream IP camera live video display Modify net...

Страница 109: ...d password which is onvif Dahua test tool IPC TESTE user name and password not web user name and password Factory reset setting camera will be soft reset and the device s user name password and networ...

Страница 110: ...the Update menu Select Local Update to update via the SD card or select Online Update to check for updates on the internet If there are applications that need updating the applications will be display...

Страница 111: ...ntenance in the evening or in the dark Click icon to enter While in the flashlight app click the red button to turn on the LED lamp Press it again to turn it off If you don t press the red button to s...

Страница 112: ...camera and IP tester be on the same network segment for the browser to interface with the camera If they are not in the same segment click the button or press RETRUN to exit Open the Settings app fro...

Страница 113: ...ents display Click each record bar to show the details Press the record bar for several seconds prompt whether delete it 3 3 41 System Setting Click icon to enter Language Select your desired language...

Страница 114: ...ynamic allocation to use DHCP To test multiple network segments click Advanced and then click Add to enter another IP address for the IP tester After setting an advanced IP address refer to the photos...

Страница 115: ...Page 110 Select and press WIFI several seconds to set static IP address Wi Fi hotspot input SSID name and password and then click ok to create Wi Fi hotspot...

Страница 116: ...can also format the SD card or unmount it before removing it FTP server Once the IP tester connects to a network a computer can be used to read the SD card files via FTP Start the FTP server and then...

Страница 117: ...t it to network and write your feedback Lock Screen the meter default is not locked You can choose password Lock screen pattern Lock screen or NO Password Lock Screen Set password you can input digita...

Страница 118: ...ernal or external storage Click on the upper right corner Icon will pop up menu you can select other operation or exit Browse It includes Music Videos Pictures Documents zip file etc It is convenient...

Страница 119: ...ktop style you can select Lite mode or normal mode Theme Pressing square area s any color icon several seconds the selected color icon will be auto move the rectangle area if you press selected color...

Страница 120: ...finished color setting click set to set it as desktop or application background Set as desktop background Setting color as desktop background Set as application background Set color as application ba...

Страница 121: ...ick more to select pictures from local file and click set to set picture as background Sliding effect Tester s sliding effect includes stereo effect folding effect Left and right folding rotate effect...

Страница 122: ...t supports up to 1080P resolution 3 6 PoE power output The IP tester supports PoE Power over Ethernet output to an IP camera via the LAN port Data transmission and 48VDC use the network cable s 1 2 3...

Страница 123: ...lt The smaller end of the supplied converter cable connects to the tester s DC12V 2A OUTPUT and the other end connects to the camera s power input Application Power output function is mainly used in t...

Страница 124: ...lose to 2A if the IP camera s power is over 2V the tester will auto enter protection mode Disconnect all the connections of the tester and then connect the tester with power adaptor to resume the test...

Страница 125: ...mera display image from the camera modify IP user name and password parameters etc DH test tool Dahua camera test modify IP user name and password parameters etc IP camera type ONVIF ONVIF PTZ Dahua I...

Страница 126: ...ameter 12V 2A power output Output DC12V 2A power to camera USB 5V power output 5V 2A power output only NO data PoE power output 48V PoE power output Max power 24W Screen management Lite mode and norma...

Страница 127: ...rent Resistance Capacitance Data hold Relative measurement Continuity testing Testing speed 3 times seconds Data range 6600 6600 Optical power meter Optional Calibrated Wavelength nm 850 1300 1310 149...

Страница 128: ...rate 3times s Current modes for clamp meter with ZERO function Isolation the Multi meter connector must be isolated with the other connector DC voltage Range Accuracy Resolution 660mV Manual range 0 3...

Страница 129: ...nt Range Accuracy Resolution 6 600mA 0 5 3 1uA 66 00mA 10uA 660 0mA 100uA 10 00A 1 5 10mA Resistance Range Accuracy Resolution 660 0 0 8 5 0 1 6 600K 0 8 2 1 66 00K 10 660 0K 100 6 600M 1K 66M 1 2 5 1...

Страница 130: ...solution 6 600nF 0 5 20 1pF 66 00nF 3 5 8 10pF 660 0nF 100pF 6 600 F 1nF 66 00 F 10nF 660 0 F 5 8 100nF 6 600mF 1 F 66 00mF 10 F 4 3 Optical power meter specifications Measure Range dBm 70 10dBm Wavel...

Страница 131: ...power 5mW Optional 10mW 20mW Modulation mode CW 1Hz 2Hz Measurement Range 5KM Optional 10 20KM Connector FC PC exchangeable Working Temperature 10 50 Operating Temperature 20 70 The data above is onl...

Отзывы: