background image

FIRST USE

 OF THE DEVICE :

HIGH OR LOW SALT LEVEL WARNINGS & BACKWASH

For a quick and efficient first use of  the device, we advise to set up the machine as follows :

 

1. WATER CHECKING :

 
- Check 

salt level 

(ideal 2.5 - 3 g/l)

- Check 

pH

 (ideal 7.0-7.4)

- Check 

stabilizer 

: 40 ppm max

 

2. GENERAL REMINDERS :

- Make sure the 

cell is properly installed on the pipes.

 The water must go out of  the cell on the same side as the power

cable.

- Make sure the power supply unit is connected on a 

permanent 230V plug

 (not controlled by the filtration system) and

properly protected (circuit b differential)

- Connect the cell to the power supply unit and switch on the electrolysis cell with the green button on the power supply
unit, 

the cell screen must light up

.

- Check that side button 

is on 100 %

 

3. QUICK SET-UP :

 

- Choose 

P9

 setting. Press one time on        , then press on        until 

P9

 and again one time on        .   

Start filtration, check that the indicator lamp on left of the screen is on (middle indicator lamp)

Check chlorine production 

(some air bubbles may be seen into the cell if  water flow is too weak) and check light 

is on.

- After several days/weeks, if  chlorine production is too low or too high, 

adjust filtration

 time and/or 

n7 

 parameter of  the 

cell,which allows to increase or lower production power. 

SHORT  FILTRATION POWER CUTS :

Warning : short power cuts (less than 1 minute) on the filtration pump or on 230V may lead to default of  
the device. This default  stops chlorine production but is not harmful to the device.

In case of  default message on the screen (E5, E6…), we advise to turn the device off  (green button
on the power supply unit) for 2 to 3 minutes and to restart it: if  default is one of  the above mentioned
cases, this action may be sufficient to cancel the default message, and may allow the device to work
properly again. Check if  it works properly after a few minutes.

IN CASE OF BACKWASH :

Turn off  the device while backwashing the filter. The device should remain turned off  during backwash 
(5 minutes).

ZELIA ZLT : 

QUICK START

Отзывы: