IB-TR3000P Thermostat Instructions
See overleaf for further setting up information
ver 1.2
This thermostat is a combination model allowing you to
choose between 3 different models. A, AF and F model.
A model: air only, with built in sensor
AF model: air & floor , with both built in and remote sensor
F model: floor only, with remote sensor
General Settings
Press buttton to Turn on/off the thermostat. When thermostat is turned off, the LCD will only display current room temperature.When the thermostat is
turned off, press and hold button M for 3 seconds to bring up a configuration menu. In this mode, press button M to select different features’ setting.
(Part I)
Menu #
1
Model (model selection)
Sd (switching differential)
ATC (air temp calibrate)
FTC (floor temp calibrate)
TR--AF (AF model only)
(TR= Temp readout )
MAXFT (set maximum floor
temp in AF model)
BL (backlight turning-on time
setting)
TF (temperature format)
CLOCK
24 (default), 12- hour or 24-hour clock system
PTD (program time delay)
2
3
4
5
6
7
8
9
10
11
12
Features description
Features Explanation
Adjustment
1 = 1 degree(default), 1.5 = 1.5 degrees.........
-1 = decrease 1 degree, 1 = increase 1 degree...
5s , 10s , 15s ,20s (default) , 25s, 30s.
A= to show air temperature, F=to show floor temperature,
A--F = to show both in 5 second intervals
40 degree(default)
30 seconds(default) On= always on, OFF= always off
C or F
Remarks:
Not all menus are visible in certain models. For example, if you set the thermostat to A or F model, menu 6 and menu 7 will not be visable.
A, AF, F
(press up or down button to adjust)
-1 = decrease 1 degree, 1 = increase 1 degree...
This product should be installed by a qualified electrician.
If the floor sensor is short-circuit or broken, the LCD will display “Err” and the thermostat will cut off output.
Please Note: one of the following error messages will appear if one of these problems occur:
The numbers of degree difference before switching.
The default is 1°C which means the thermostat will
switch the heating on 0.5°C below the set temperature
and will turn it off 0.5°C above the set temperature.
With a 2°C differential, the heating will switch on 1°C
below the set temperature and will switch off 1°C
above the set temperature.
This is to calibrate air temperature if required.
This is to calibrate floor temperature if required.
This gives more time for user to set the programmes
before reverting back to standard display
This gives option to choose to show air temperature,
floor temperature or to show both floo& air in interval.
This is to protect the floor surface.
This is to set the backlight turning-on time. User
can also set the backlight always on or off.
This alows users to select between °C or °F.
12/24 HOUR clock system selection
Buttons and LCD display
Button / Icon
Description
Turning on/off thermostat
Menu button / Program button
Increase the set value
Decrease the set value
Set the time and week days
M
The buttons are locked.
Heating is turned on
Button / Icon Description
Auto mode
Vacation mode
Manual override
Frost protection activated
Set temperature
Programmes number
Room temperature
RT
AUTO
SET
Floor temperature
Economy temperature
Comfort temperature
FT
The difference between set
temperature and room temperature,
more bars means more difference
Wed
Auto
override
SC(setpoint configuration)
4 means 4 independent setpoints, 2 means: setpoint 1 is the
same to setpoint 3 , setpoint 2 is the same to setpoint 4
This allows user to select 2 kinds of default setpoints
FP(Frost protection)
on= activated, off= deactivated
This is to avoid room temperature goes below 5°C