IB-TR3000P Thermostat Instructions

See overleaf for further setting up information

ver 1.2

This thermostat is a combination model allowing you to 

choose between 3 different models. A, AF and F model.

A model:      air only, with built in sensor

AF model:   air & floor , with both built in and remote sensor

F model:      floor only, with remote sensor

General Settings

Press  buttton             to Turn on/off the thermostat. When thermostat is turned off, the LCD will only display current room temperature.When the thermostat is 

turned off, press and hold button M for 3 seconds to bring up a configuration menu. In this mode, press button M to select different features’ setting.

(Part I)

Menu #

 1

Model (model selection) 

Sd (switching differential) 

  ATC (air temp calibrate) 
  FTC (floor temp calibrate) 

TR--AF    (AF model only)

(TR= Temp readout  ) 

MAXFT (set maximum floor

 temp in AF model) 

BL (backlight turning-on time 

setting) 

TF (temperature format) 

CLOCK 

24 (default),  12- hour or 24-hour clock system

PTD (program time delay) 

2

3

4

5

6

7

8

9

10

11

12

Features description

Features Explanation

Adjustment

1 = 1 degree(default),  1.5 = 1.5 degrees.........

-1 = decrease 1 degree,  1 =  increase 1 degree...

  5s  ,  10s   , 15s   ,20s (default) , 25s, 30s.

A= to show air temperature,  F=to show floor temperature,

  A--F = to show both in 5 second intervals 

  40 degree(default)

   30 seconds(default)  On= always on, OFF= always off

  C  or    F

Remarks:

 Not all menus are visible in certain models. For example, if  you set the thermostat to A or F model, menu 6 and menu 7 will not be visable.

A, AF, F

(press up or down button to adjust)

-1 = decrease 1 degree,  1 =  increase 1 degree...

This product should be installed by a qualified electrician.

If the floor sensor is short-circuit or broken, the LCD will display “Err” and the thermostat will cut off output.

Please Note: one of the following error messages will appear if one of these problems occur: 

The numbers of degree difference before switching. 

The default is 1°C which means the thermostat will 

switch the heating on 0.5°C below the set temperature 

and will turn it off 0.5°C above the set temperature. 

With a 2°C differential, the heating will switch on 1°C

below the set temperature and will switch off 1°C

above the set temperature.  

This is to calibrate air temperature if required.
This is to calibrate floor temperature if required.

This gives more time for user to set the programmes

before reverting back to standard display

This gives option to choose to show air temperature,

floor temperature or to show both floo& air in interval.

This is to protect the floor surface.

This is to set the backlight turning-on time. User 

can also set the backlight always on or off.

This alows users to select between °C or °F. 

12/24 HOUR clock system selection 

Buttons and LCD display

Button / Icon 

Description

Turning on/off thermostat

Menu button /  Program button

Increase the set value

Decrease the set value

Set the time and week days

M

The buttons are locked.

Heating is turned on

Button / Icon  Description

Auto mode

Vacation mode

Manual override

Frost protection activated

Set temperature
Programmes number
Room temperature

RT

AUTO

SET

Floor temperature

Economy temperature

Comfort temperature

FT

The difference between set 
temperature and room temperature, 

more bars means more difference

Wed

Auto

override

SC(setpoint configuration)

4 means 4 independent setpoints,  2 means: setpoint 1 is the 

same to setpoint 3 , setpoint 2 is the same to setpoint 4

This allows user to select 2 kinds of default setpoints

FP(Frost protection)

on= activated,  off= deactivated

This is to avoid room temperature goes below 5°C 