Page
6
of
20
IV.
Technical Specifications
System
System weight
Dry
76 lbs (30.4 kg)
Wet
83 lbs (33.6 kg)
Exterior dimensions (L x W x D)
24.9 in x 23.7 in x 13.1 in
(63.2 cm x 60.2 cm x 33.3 cm)
Electrical requirements
Voltage
12/24 VDC or 120/230 VAC
Maximum height above water
Priming
8 ft (2.4 m)
Operating
20 ft (6.1 m)
Safe to run pump dry?
Yes
Temperature range
Dry Storage
-40 - 140
o
F (-40 – 60
o
C)
Operating
33 – 115
o
F (0.5 – 46
o
C)
Nanomesh™
Contaminant removal ability
See Appendix A
Operating water source temperature range
40 – 104
o
F (4 – 40
o
C)