SMOKE ALARM

HEAT ALARM

FLOOD ALARM

Содержание FLOOD

Страница 1: ......

Страница 2: ...ON AND RETAIN FOR FUTURE USE FLOOD ALARM DEVICE Commercial reference 5101 002 Developed by CAVIUS The Flood Alarm is designed to detect a leak of water from washing machines water pipes or under sink cabinets It can also be used to detect flooded basements ...

Страница 3: ...3 3 Areas where NOT to install the flood alarm 15 4 Placement 16 5 Accessory wall mounting base with probe 17 6 Test of the RF function 19 7 Normal mode 21 8 Alarm mode 22 9 Pause Hush function 24 10 Add extra device 26 11 Low battery signal 27 12 Battery replacement 28 13 Trouble shooting 29 14 Other information 30 ...

Страница 4: ...house group is 32 Please note These must be alarms from the CAVIUS The distance between interlinked alarms depends on the house layout and they should always be tested after installation It is not advised to fit any two alarms with a spacing of more than 10m Diameter 60mm Height 37mm 1 ...

Страница 5: ...ttery Please note that correct operation of the flood alarm device is ensured by use of one of the following batteries DURACELL PANASONIC or HUIDERUI Interlinked by RF 868 MHz Complies to standards RoHS REACH R TTE EN300 220 1 and 2 EMC directive 2004 108 EC 2 ...

Страница 6: ...SENSOR PINS ...

Страница 7: ...TEST HUSH BUTTON RED LED SOUND ...

Страница 8: ...1 HOW TO SET UP AND CONNECT ALARMS 1 Open the flood alarm top cover by twisting counter clockwise 2 Remove the Test button Lid to access to the battery and the RF learn slide switch 5 ...

Страница 9: ...by pulling out the battery isolation strip as shown ISOLATION STRIP DO NOT REMOVE THE PRODUCT LABEL Please note The product label must not be removed as it contains important information regarding the product 6 ...

Страница 10: ...All alarms that need to be connected in the house should be put into Learn Mode by sliding the switch on the top of the alarm to the Learn mode position 1 2 LEARN MODE NORMAL MODE 7 ...

Страница 11: ...The red LED will light up to indicate that Learn Mode has been selected Do not take out the battery during Learn Mode as this will interrupt the learn process 8 ...

Страница 12: ...Press and hold the test button at one alarm only until it beeps and the LED flashes This alarm will become the master and will start sending out a specific house code to the other alarms 9 1 2 ...

Страница 13: ...As the other alarms receive the specific house code they will also flash the LED light When all alarms flash the red LED they are connected and can be switched out of Learn Mode and installed 10 ...

Страница 14: ...1 Switch out of Learn Mode by sliding the switch on the top of the alarm to the Normal mode position 11 NORMAL MODE ...

Страница 15: ...2 Remount the Test button Lid 3 Close the flood alarm top cover by twisting clockwise 12 ...

Страница 16: ...LARM Install a flood alarm where it is hard to discover possible leaks Install next to washing machine dishwasher under sink cabinet or in the cellar Install in basements Place the alarm where it is reachable in order to test the battery 13 ...

Страница 17: ...Minimum flood alarms Minimum smoke alarms Minimum heat alarms ...

Страница 18: ...INSTALL FLOOD ALARMS On the ceiling On the wall unless using accessory wall mounting base see page 17 In rooms where temperature goes outside 0 C to 40 C Place the alarm where it is reachable in order to test the battery 15 ...

Страница 19: ... on the floor near to possible leaks NOTE If you place the flood alarm in places where a potential water leak flood can rise higher than 2cm there is a risk of your flood alarm beeing damaged In these places we recommend wall mounting base with probe 16 ...

Страница 20: ... purchased separately For installation in basements with risk of flooding or areas with difficult accessibility Place the flood alarm base on the wall and the probe on the floor Make sure that the probe reaches required level either to the ground or down the drain 5 ACCESSORY WALL MOUNTING BASE WITH PROBE 17 ...

Страница 21: ...18 Turn the alarm until it clicks all the way in and can t be turned then it is correct position USE THE ENCLOSED SCREWS AND PLUGS ...

Страница 22: ...flashes correctly every 48sec Pressthetestbuttononanyalarmforatleast6 5seconds count 2 sets of 3 sound sweeps This will send out a test signal from the alarm all other connected alarms should receive the signal within a short time The alarms will emit a short beep and the LED will flash every 8 seconds for 2 minutes NOTE Test function also allows to send a depleted RF signal to ensure an optimal o...

Страница 23: ...If required this indication can be stopped early on each alarm by a short press of the test button TIP It is safe to cover the sound output hole with your finger during the testing to minimize the sound level emitted Test of the water leak function To test the water leak function place the flood alarm on a wet cloth and it should go into alarm 20 ...

Страница 24: ...7 NORMAL MODE In normal mode the LED will flash every 48 seconds to show correct operation 21 ...

Страница 25: ...ransmit the alarm signal to the other connected alarms which will also sound the alarm signal after a short delay The CAVIUS Wireless Family have two different alarm signals Alarm signal 1 is life threatening alarms like a smoke alarm Alarm signal 2 is a non life threatening alarm like a flooding alarm 22 ...

Страница 26: ...23 Smoke alarm signal Heat alarm signal Flood alarm signal CO alarm low level signal CO alarm high level signal Please note that only the originating alarm s LED will flash so it can be identified ...

Страница 27: ... alarm only indicated by the flashing LED and after 10 minutes goes back to normal function The reason that you can not pause the other alarms only the originating alarm is for your own safety It is necessary to locate the source of the alarm to make sure that it is not a situation that needs your attention 24 ...

Страница 28: ...SMOKE ALARM HEAT ALARM FLOOD ALARM ...

Страница 29: ... run on the same frequency and use the same data protocol This means that the wireless system can consist of a combination of smoke heat flood etc Place all alarms into Learn Mode and repeat section 1 Always test connection to all devices by repeating test function section 6 after adding devices 26 ...

Страница 30: ... short beep will sound out every 48 seconds for 30 days The alarm effected by the low battery will only beep no other connected alarms will sound It is safe to change batteries in the alarms without going through the learn process again they will not forget the codes during the battery change process 27 ...

Страница 31: ...battery detach the cover of the flood alarm by twisting counter clockwise Replace the battery respecting the polarities See page 5 for more information Put the test button back close the casing by twisting it clockwise and test the alarm 28 ...

Страница 32: ... alarm does not work when the test button is pushed or tested on a damp cloth the probable cause is a faulty battery Check if the battery is worn out or wet and replace it Always test the alarm after replacement of battery If the problem continues please visit www cavius com for any trouble shooting 29 ...

Страница 33: ...MATION Do not paint the alarm Note the local country regulations regarding installation Disposal For battery and product please dispose properly at the end of life This is electronic waste which should be recycled 30 ...

Страница 34: ...ity for any errors which may appear in this manual Further more Cavius Aps reserves the right to alter the hardware software and or specifications detailed herein at any time without notice and Cavius Aps does not make any commitment to update the information contained herein All the trademarks listed herein are owned by their respective owners Copyright Cavius Aps 31 ...

Страница 35: ...DEVELOPED BY CAVIUS Aps Julsøvej 16 DK 8600 Manufactured in P R C 126811 rev1 ...

Страница 36: ......