• Place an alarm between possible fire sources and bed-

rooms as minimum,

• Alarms on each floor and in hallways and stairways.

• Alarms in each room such as bed rooms and living 

rooms. 

Additional alarms increase the security.

Installation of alarm:

1. Detach the alarm from the mounting base by twisting 

counter clockwise. Use the mounting base to mark the 

screw holes on the ceiling. Use the enclosed screws 

and plugs to install the mounting base. Once the 

mounting base is installed on ceiling or wall, attach the 

alarm by twisting clockwise.

2. After mounting, test the alarm by pushing the test 

button on the top and get a loud alarm tone. 

Please note: The label in the product must not be removed 

as it contains important information regarding the 

product.

The alarm may NOT be placed:

• In dusty rooms
• At the top of high pointed ceilings or in ceiling corners 

or within 50 cm of a wall.

• In rooms where the temperature goes out side +4

o

 to 

38

o

C or above 90% relative humidity not condensing. 

• In kitchen, garage and fireplaces where damp,

gases and smoke could occur. Place the alarm where 

it is reachable in order to test the battery and for main

tenance.

Fault finding: If the smoke alarm activates without 

visible cause, the possible cause could be:
• Dust particles in the smoke chamber which can be re

moved by vacuuming the mesh.

• High humidity condensing which can be resolved by 

drying the smoke alarm.

If the smoke alarm does not work when the test button is 

pushed, the probable cause is a faulty battery and the 

smoke alarm must be replaced. 

Other information: Do not paint the alarm. 

Disposal: For product, please dispose properly at the 

end of life. This is electronic waste which should be 

recycled.

Please note local regulations about information to your 

insurance company regarding installed smoke alarms..

Commercial reference: 2007-003

Developed by CAVIUS

PLEASE  READ THE USER GUIDE 

CAREFULLY BEFORE USE AND 

RETAIN FOR FUTURE USE!

CAVIUS smoke alarm is designed for private homes, 

camping trailers and caravan installations.

Technical information:

Type of alarm: CAVIUS smoke alarm is a photo elec-

tric smoke alarm.

Alarm signal: Fire alarm condition is indicated by a series 

of repeated tones. The minimum sound level is 85 dB 

at 3 meters.

Battery: Powered by a non-replaceable 3V CR123 Lith-

ium battery with 10-year life (included).

IMPORTANT: Do not replace the battery. Replace 

the product if the battery fails.

Low battery indicator: A short “beep” will sound and 

LED flash every 48 seconds when the battery is near the 

end of life. In this stage it will continue for a minimum 

30 days.

It is recommended to change the smoke alarm after 10 

years, or if the alarm has suffered any damage. The 

alarm is not active unless it is inserted in the mounting 

base.

Always check the alarm after inserting in the mounting 

base (allow a few seconds before testing).

 

Placement: The smoke alarm is designed for placement on a 

ceiling or wall. The smoke alarm should be a minimum of 

50 cm from the wall,  with a minimum of one smoke alarm 

per floor and a maximum distance between smoke alarms 

of 10 meters.

Alarm signal: The alarm has a visual and acoustic alert 

tone. In the passive state, the LED will flash every 48 

seconds to indicate normal function. In an alarming state 

the LED will flash and the alarm will emit a sweeping 

sound pattern design to alert occupants.

Hush function: In case of unintentional alarm condition 

or false alarms, press the top button. This will hush the 

alarm for 10 minutes, after which time it will automatically 

resume its normal alarm function.

Maintenance: The smoke alarm should be vacuum 

cleaned once per quarter, and it can be wiped with a 

damp cloth. (Do not open the alarm).

Test the alarm at least once per quarter by pushing the 

test button. The alarm will self test and give a loud alarm 

tone.

The best places to mount the alarm: 

The CE mark affixed to this product confirms its com-

pliance with the European Directives which apply to the 

product and, in particular, its compliance with the har-

monized specifications of standard EN 14604 relating to 

Construction Products Regulation  305/2011.

All Rights reserved: CAVIUS Aps assumes no responsi-

bility for any errors, which may ap pear in this manual. 

Furthermore, CAVIUS Aps reserves the right to alter the 

hardware, software, and/or specifications detailed herein 

at any time without notice, and CAVIUS Aps does not 

make any commitment to update the information 

contained herein. All the trademarks listed herein are 

owned by their respective owners. Copyright © CAVIUS Aps.

EN 14604:2005 + AC :2008 

DoP no.: 2007-003

0333

19

Minimum

Minimum 50cm 

from wall

Wall

Ceiling

UK

Mark up screw holes with a pen

Use the enclosed screws 

and plugs for installation

Sound &

Test button

Mounting base

Chamber filter

Minimum 30cm and maximum 50cm from 

ceiling

Wall

Ceiling

Declared performances 4.1-4.19+5.2-5.24: Passed

Download DoP document: www.cavius.com

127404 rev2