4.3 Initial Set-Up
After first receiving the CaviBlaster power unit, the following must be completed:
See Figures 2.1 for item locations.
1. Add oil to pump by completely filling pump to top of fill port.
2. Install fill plug.
3. Stand unit on end with pump motor at top.
4. Remove oil pressure compensator fill port cap.
5. Fill oil pressure compensator and hose with oil.
6. Allow unit to sit for several minutes to vent any trapped air.
7. Top-off oil as required.
8. Replace oil pressure compensator fill port cap.
9. Set unit back down on vibration mounts.
10. It is important that there is no air trapped in the pump oil system.
11. Connect hydraulic power unit hoses.
12. Connect water pressure hose.
The CaviBlaster 2040-ROV-M2 can be used with seawater but must
be flushed and rinsed with fresh water after every use in seawater.
Failure to flush and rinse the power unit after use in seawater will
result in increased wear and tear on components and can cause the
pump valve(s) to stick in the open position. This will prevent the
system from producing the correct operating pressure.
(EOS)
Page -
13
For more information please email [email protected] or call 1-(352)275-5319
Pump fluids may have been removed for shipment.
Check ALL fluid levels prior to starting.