4.3.3 Water Supply Conditions.
a) Forced inlet water condition using the supplied electric water pump.
b) An outside water source capable of supplying a minimum of 40 GPM (150
LPM) at a
maximum pressure of 50-PSI (3.5 BAR)
.
c) Gravity feeding water source (See Figure 4.3). Use a hose with a diameter of
at least 1-
1/2” to connect the water tank to the power unit water inlet.
Figure 4.3
– Gravity Feeding Source
a) Using the Feed Pump System:
•
Verify the main power switch, HPP motor switch and feed pump motor are
switched to OFF.
•
Ensure the E-
Stop button is ‘
Pushed In
’ so that the power supply has been
disconnected. (See Figure 2.2).
•
Connect the cam-lock socket on the 1-
1/2” clear PVC feed hose to the water
inlet connection on the control panel (See Figure 2.2). Place the other end of
the hose in the water supply.
•
THE PUMP SYSTEM MUST BE FULLY PRIMED BEFORE STARTING THE
HPP PUMP OR SERIOUS DAMAGE TO HPP PUMP WILL OCCUR. REFER
TO SECTION 4.3.2 (ABOVE) FOR PRIMING INSTRUCTIONS.