Cavaliere AirPRO 238 Professional Series Скачать руководство пользователя страница 1

Installation Guide 

and Users Manual

Under Cabinet/Wall Mount Range Hood

AirPRO 238 Professional Series 

(PST/T2)

NOTICE:

Installer:

 Leave this guide with the homeowner

Homeowner:

 Keep this guide for future reference

IMPORTANT:

Read and save these instructions.

Rev. 3060u.1d

Содержание AirPRO 238 Professional Series

Страница 1: ...anual UnderCabinet WallMountRangeHood AirPRO 238 Professional Series PST T2 NOTICE Installer Leave this guide with the homeowner Homeowner Keep this guide for future reference IMPORTANT Read and save these instructions Rev 3060u 1d ...

Страница 2: ......

Страница 3: ...rities Before servicing or cleaning unit switch power OFF at service panel and lock service panel to pre vent power from being switched ON accidentally Clean grease laden surfaces frequently To reduce the risk of fire and to disperse air properly make sure to vent air outside DO NOT vent exhaust into spaces between walls crawl spaces ceiling attics or garages Ducted fans MUST always be vented to t...

Страница 4: ...ny bodily injuries whether caused directly or indirectly by the range hood Clean ventilating fan frequently Always use appropriate cookware and utensils size Always use cookware appropriate for the size of the surface element To reduce the risk of injury to persons in the event of a stove top grease fire SMOTHER FLAMES with a close fitting lid cookie sheet or metal tray then turn OFF the burner BE...

Страница 5: ...Installation 10 11 Range hood operations 12 17 USE AND CARE Troubleshooting 18 Use and care information 19 Specifications 19 Measurements diagrams 20 24 MAINTENANCE Cleaning 25 Replacing the filter light bulb 25 WARRANTY Coverage exceptions 26 Disclaimer Contact Us 27 Tools needed Page 3 Level Flat blade and Phillips screwdrivers Powered screwdriver or drill Measuring tape Utility knife Marker or ...

Страница 6: ...ase Tunnel Qty 4 PCS For sheet rock only Qty 4 PCS Qty 8 PCS Qty 8 PCS Qty 8 PCS Qty 10 PCS Round head Qty 8 PCS Flat head Optional for Single piece Chiomney Single piece Chimney Optional Baffle Filter Spacer 8 Ducting Transition X2 for Dual Blowers 10 Ducting Transition Optional for Dual Blowers ...

Страница 7: ...s recommended between stove top and the bottom of range hood It is recommended that the range hood be vented vertically through the roof through 8 20 3 cm or bigger round metal aluminum vent work The size of the vent should be uniform Use no more than three 90 elbows Make sure there is a minimum of 24 61 cm of straight vent between the elbows if more than one elbow is used DO NOT install two elbow...

Страница 8: ...ld be no higher than 31 inch It is important to install the hood at the proper mounting height Hoods mounted too low could result in heat damage and fire hazard while hoods mounted too high will be hard to reach and will loose its performance and efficiency If available also refer to stove top manufacturer s height clearance requirements and recommended hood mounting height above range Due to diff...

Страница 9: ...r terminate duct work into spaces between walls crawl spaces ceiling attics or garages All exhaust must be ducted to the outside Use metal aluminum duct work only Fasten all connections with sheet metal screws and tape all joints with certified Silver Tape or Duct Tape Use caulking to seal exterior wall or roof opening around the cap Vertical roof venting Roof cap Option 2 Side wall cap Horizontal...

Страница 10: ...T Save this Installation Guide for electrical inspector s use The range hood must be connected with copper wire plug only The range hood should be connected directly to the fused disconnect or circuit breaker box through flexible armored or non metallic sheathed copper cable A U L or C S A listed strain relief must be provided at each end of the power supply cable Wire sizes copper wire only and c...

Страница 11: ... performance of the hood IMPORTANT Peel white plastic protective coat off the hood if any Use silver tape or duct tape to seal joints between pipe sections For installing under the cabinet with recessed bottom attach 4 inch wide wood filler strips not provided on each side Refer to Figure 1 Using references in Measurements and Diagrams on Page 20 create access opening for electrical wires and hood...

Страница 12: ...cess opening and center the hood beneath the cabinet v From inside of the hood place screws into the exact center of each knockout hole and secure to cabinet bottom vi Finish tightening all screws until secure Be careful when using electrical screwdriver damage to the range hood may occur CAUTION Make certain the range hood is secure before releasing For safety purpose pre drilled mounting holes a...

Страница 13: ...fle filter and stainless spacer placement Refer to Figure 10 for the following five steps Angle baffle filter toward back of hood Push baffle filter up until almost level Slide forward into recess behind the front of hood Lower baffle filter Slide back until it fits into resting positions Repeat Step 8 to install all baffle filters and stainless spacers 8 OPTIONAL Install heating lamps not include...

Страница 14: ... Delay Digital Timer Indicates the length of time left for delay off function Power Off Delay Timer Indicator Lights up when auto shutdown delay timer function is on Controls Automatic cleaning reminder This range hood is equipped with a cleaning reminder that will activate following 30 hours of use When blower motor starts to rotate cumulative running time will be shown in Power On Elapsed Digita...

Страница 15: ...econds to activate delay off timer Power off delay indicator will lit up and power off delay digital timer will begin to countdown when it reaches zero the blower motor will shut down Adjusting the light Press Light button once to turn on the lights and once again to turn off the lights While the lights are off press and hold Light button for over 3 seconds to dim the lights from low to high Level...

Страница 16: ...Page 14 Control type 1 6 speed Range Hood Operations Wiring Diagram Continued NOTE Wiring Diagrams shown above with GU10 PAR20 light configuration A transformer is required for MR16 Lights ...

Страница 17: ...he length of time left for delay off function Controls Automatic cleaning reminder This range hood is equipped with a cleaning reminder that will activate following 30 hours of use The blower motor running time starts to accumulate when it first rotates when the running time reached 30 hours the Cleaning Reminder Indicator C flashes and reminds user to clean the range hood After cleaning the filte...

Страница 18: ...once to turn on the lights and once again to turn off the lights While the lights are off press and hold Light button for over 3 seconds to dim the lights from high to low Level of brightness will be stored in system s memory CAUTION DO NOT touch the lights until switched OFFand cooled Note Light settings are independent from other settings including power off delay and lights has to be manually t...

Страница 19: ...17 Range Hood Operations Wiring Diagram Continued Control type 2 4 speed Control type 2 6 speed NOTE Wiring Diagrams shown above with GU10 PAR20 light configuration A transformer is required for MR16 Lights ...

Страница 20: ...mple 9 duct over 8 hole and loosely secured Check if duct is clogged or if damper unit half cir cular flapper is not installed correctly or opening properly A tight mesh on a side wall cap unit might also cause restriction to the air flow The lights work but the blower is not spinning at all 4 is stuck or is rattling The blower might be jammed or scraping the bot tom due to shipping damage Please ...

Страница 21: ...ly DO NOT operate blowers when filters are removed Never disassemble parts to clean without proper instruc tions Disassembly is recommended to be performed by qualified personnel only Read and understand all instructions and warnings in this manual before proceeding Specifications3 Body Design Seamless Stainless Steel Satin Finish Power Rating 220V 50Hz or 120V 60Hz USA Canada standard General Inp...

Страница 22: ...e estimated With optional single piece chimney Measurements and Diagrams Measurements and Diagrams All measurements in parenthesis are in millimeter All inch measurements are converted from millimeters thus inch measurements are estimated With optional single piece chimney Page 20 Single blower configuration AP238 PST Dual blower configuration AP238 PST2 ...

Страница 23: ...er All inch measurements are converted from millimeters thus inch measurements are estimated Without optional single piece chimney Single blower configuration AP238 PST Measurements and Diagrams Continued Dual blower configuration AP238 PST2 Page 21 ...

Страница 24: ...sis are in millimeter All inch measurements are converted from millimeters thus inch measurements are estimated Single blower configuration AP238 PST Measurements and Diagrams Continued Dual blower configuration AP238 PST2 Page 22 ...

Страница 25: ...rews 15 Gasket 4 Blower Assembly 16 Baffle Filter 5 Wiring Box Cover 17 Stainless Steel Spacer 6 Wiring Box 18 Baffle Filter Handle 7 Heat Lamp Socket optional 19 Screws 8 Screws 20 Switch Assembly 9 Heat Lamp Socket Box optional 21 Electrical Assembly 10 Oil Tunnel 11 Real Halogen Light Heat Lamp Panel 12 Front Halogen Light Panel ...

Страница 26: ...Motor 4 2 Air Flow Grill 4 6 Right Squirrel Cage 4 3 Left Locknut 4 7 Right Locknut 4 4 Left Squirrel Cage 4 8 Air Chamber Optional Single Piece Chimney Sold Separately No Description No Description 3 Screws 3 16 x 3 8 24 Single Piece Chimney Cover Size Varies Page 24 ...

Страница 27: ...DO NOT use ordinary steel wool or steel brushes Small bits of steel may adhere to the surface and cause rusting DO NOT allow salt solutions disinfectants bleaches or cleaning compounds to remain in contact with stainless steel for extended periods Many of these compounds contain chemicals which may be harmful Rinse with water after ex posure and wipe dry with a clean cloth Cleaning Stainless Steel...

Страница 28: ...nsumable parts such as light bulbs metal and charcoal filters The natural wear of finish and wear due to improper maintenance use of corrosive and abrasive cleaning products pads and oven cleaner products Chips dents or cracks due to abuse misuse freight damage or improper installation Damage of product caused by accident fire floods or act of God The manufacturer and or distributor reseller is no...

Страница 29: ...ing fee of 15 will be charged for all approved return s Exchanges or returns may not be accepted if any packaging is missing Make sure to inspect the hood for damages and defects before installation Appearance flaws of the hood found after installation and not affecting hood performance is not covered under our warranty for returns or exchang es Service visits not covered under warranty will carry...

Страница 30: ...Page 28 Your Notes ...

Страница 31: ...Page 29 Your Notes ...

Страница 32: ...Page 30 Your Notes ...

Страница 33: ...ig Drive Garden Grove California 92841 Tel 714 622 1550 Fax 714 622 1559 http www cavalierehoods com Cavaliere 7372 Doig Drive Garden Grove California 92841 Tel 714 622 1550 Fax 714 622 1559 http www cavalierehoods com ...