CommandPro
®
General Purpose & Safety Applications
User Manual
13
9M02-9028-A031-EN
Rev 4
5.3
Transmitter Operation (22T10A Maintained Link Mode)
IMPORTANT
To stop the system in an emergency, press and hold the OFF/STOP button. Pressing and holding
this button down stops all functions.
1. Press and release the RADIO ON button. Verify that the status LED starts flashing at a low rate.
Note:
You must be within radio range at all times for the system to operate. The receiver is designed to
stop all functions if the radio signal is not received.
2. Press the required switches to operate equipment as desired. Note that more than one function can be
controlled at any time.
3.
To turn the transmitter off, press the STOP button. This will send a STOP command to the receiver and
will switch off the transmitter when the button is released.
5.4
Transmitter Troubleshooting
The transmitters have an LED status indicator to aid in troubleshooting. Due to the rough treatment they may be
subjected to, most problems are likely to occur in the transmitter. The transmitter should be thoroughly diagnosed
before proceeding to the receiver.
WARNING
When testing the transmitter, the receiver can become active and cause system operation. Always
assume the system is working and will respond when testing a transmitter.
!
!