Rev 6 – Feb 2022
Page 14 of 44
Time Zone
The user can select their local time zone to correct the GPS time from UTC to local time. All data is
then stored in local time.
Interruption Cycle & Timing Settings
Cycle TimeSet the cycle time to match the same settings you have applied on your current
interrupters. The cycle time must be evenly divisible into 60 seconds. Common cycles are 1s, 2s, 4s,
5s, etc.
OFF Time
The OFF time is set by the user, which should match the off time used by the current interrupters.
Typically, the OFF time is about ¼ of the total cycle time. The ON time is calculated from the cycle
time minus the OFF time.
ON/OFF First
The Hexcorder Pro can measure the OFF or the ON measurement first. Most interrupters function
with the OFF occurring at the start of the cycle. Select the correct setting to match YOUR