background image

21

In

 more 

detail...

GB IE

Regulation of burners

Regulation of the “MINIMUM” position on the burners.
To regulate the minimum position on the burners, follow the procedure below:

1.  Turn on the burner and turn the knob to its MINIMUM position (small 

flame).

2.  Remove the knob from the tap set for standard pressure. The knob is 

found on the bar of the tap itself.

3.  Place the tap bar on the work top, use a small screwdriver that fits the 

(gold) screws located at the lower part of the tap and turn the fixing 

screw to the right or left until the flame of the burner is regulated in the 

most suitable manner to MINIMUM.

4.  Make sure that the flame does not go out when changing the position 

quickly from MAXIMUM to MINIMUM position.

Caution

The regulation described can only be carried out with 

burners that use methane gas and city gas (where 

available), whereas the screw must be fully tightened 

in a clockwise direction on burners using liquid gas.

01

Technical and legal 

information

Содержание GHDFF70AL

Страница 1: ...GHDFF70AL v1 Barcode 8422248600422 GB IE GHDFF70AL 70cm Gas on Glass Hob ...

Страница 2: ... 09 x 5 10 x 1 11 x 4 06 x 1 08 x 4 07 x 1 02 x 1 01 x 1 12 x 1 03 x 1 04 x 2 05 x 1 T E M P L A T E T E M P L A T E ...

Страница 3: ...3 GB IE Built in 70cm Gas on Glass Hob 04 Installation 25 GHDFF70AL ...

Страница 4: ...ed 05 Before you start 06 Safety 07 In more detail 09 Operation Care and maintenance Troubleshooting Recycling and disposal Technical and legal information Guarantee CE Declaration of conformity 10 13 15 16 16 22 24 Appendix 25 Installation ...

Страница 5: ...5 Getting Started Getting started GB IE Before you start 06 Safety 07 ...

Страница 6: ...ontact Customer Services on 0844 800 1128 UK 1 800 535542 Ireland and 01 56 48 02 60 France Check the package and make sure you have all of the parts listed Decide on the appropriate location for your product If this product contains glass please take care when fitting or handling to prevent personal injury or damage to the product The specifications plate is available on this appliance This plate...

Страница 7: ...ervision and instruction concerning the use of the appliance by a person responsible for their safety Means for isolating the appliance must be incorporated in the fixed wiring in accordance with the current wiring regulations An all pole disconnection switch having a contact separation of at least 3 mm in all poles should be connected in fixed wiring Damaged power cables should be replaced by a c...

Страница 8: ...mer or separated remote control system The appliance is for domestic use only When a cooking zone has been on for a long time the surface remains hot for some time afterwards so do not touch the metal surface Do not store detergents or flammable materials beneath the hob Do not leave hot oils or fats unattended as they may catch light The Manufacturer declines all liability for personal or materia...

Страница 9: ...9 In more detail In more detail GB IE Operation 10 Care and maintenance 13 Troubleshooting 15 Recycling and disposal 16 Technical and legal information 16 Guarantee 22 CE Declaration of conformity 24 ...

Страница 10: ...me goes out Auto ignition LPG conversion kit supplied Control elements Reference Description Qty Reference Description Qty A Rapid burner 1 E Burner caps 5 B Semi rapid burner 2 F Pan Support 3 C Auxiliary burner 1 D Wok burner 1 Caution This diagram may be slightly different from the layout of the appliance Operation E D E A E B E B E C F F F C B D B A ...

Страница 11: ...rresponds to a large flame Use a piezo electric spark gas ignitor Automatic electric ON switch for burners with safety device thermocouples Turn the knob fig 5 corresponding to the selected burner in a counter clockwise direction so that the knob is at MAXIMUM Once the burner is lit keep the knob pressed in for about 10 seconds in order to allow the flame to heat up the thermocouple If the burner ...

Страница 12: ...l ventilation device flue or electric fan Intensive or prolonged use of the appliance may require additional ventilation such as opening a nearby window or increased ventilation efficiency obtained by increasing the power of the mechanical ventilators where applicable Advice for the best use of the burner When boiling point is reached turn the knob to MINIMUM Always use pans with a lid Burner Reco...

Страница 13: ... Cleaning of stainless steel parts Wash these parts with soapy water and then dry them with a soft cloth The shine is maintained by regularly cleaning them with special products normally commercially available Never use abrasive powders Cleaning of burner flame dividers Given that they are not fixed the flame dividers can be cleaned by simply removing them and washing them with soapy water After d...

Страница 14: ...IE In more detail GB IE Replacement of parts Warning Always switch off the electricity supply before performing maintenance work In the event of a fault contact customer services Care and maintenance FUSE OFF ...

Страница 15: ...t been switched off 2 Check that the fuse in the spur has not blown 3 Ensure that the burner components are not excessively soiled as this can lead to ignition problems Do not take the appliance apart yourself as you may damage the hob Before calling After Sales Service please do the following 1 Check that the appliance is correctly connected 2 Read the failure text above If you are still unable t...

Страница 16: ...ng advice The symbol on the product or its packaging indicates that this product cannot be treated as normal household waste This product must be handed over to an electric and electronic equipment collection point for recycling On ensuring that this product is disposed of correctly you will help to avoid possible negative consequences for the environment and public health which could occur if thi...

Страница 17: ...pliance is being connected directly to the mains an omnipolar circuit breaker must be installed with a minimum opening of 3mm between contacts If the cable is damaged or to be replaced the operation must be carried out the by a qualified electrician with dedicated tools to avoid any accidents The installer must ensure that the correct electrical connection has been made and that it complies with w...

Страница 18: ... WARNING THIS APPLIANCE MUST BE EARTHED The appliance is supplied with a 3 core mains cable and must be connected to the electricity supply via a double pole switch having a 3mm minimum contact gap on each connector For UK only A Switched Fused Connection Unit to BS 1363 Part 4 is recommended The fuse must be rated at 13 Amps The wires in the mains lead are coloured in accordance with the followin...

Страница 19: ...n 5m3 The following table details the requirements based on the kitchen volume L x W x H in m3 The above requirements also allow use of a gas oven and grill but if there are any other fuel burning appliances in the same room consult the relevant British Standard BS5440 or Gas Safe manual The above requirements also allow use of a gas oven and grill but if there are any other fuel burning appliance...

Страница 20: ...s jets retained then the label should be changed to NATURAL Lift up the burners and unscrew the nozzle using an dedicated tool and replace the nozzles with those designed for LPG gas supply Caution The hob installation and burner changes must be carried out by a competent person ie a Gas Safe registered fitter 02 08 x4 x1 08 01 09 x1 x1 09 Technical and legal information ...

Страница 21: ...k top use a small screwdriver that fits the gold screws located at the lower part of the tap and turn the fixing screw to the right or left until the flame of the burner is regulated in the most suitable manner to MINIMUM 4 Make sure that the flame does not go out when changing the position quickly from MAXIMUM to MINIMUM position Caution The regulation described can only be carried out with burne...

Страница 22: ... any remaining balance of the GAA guarantee will be valid and any further call outs during this prescribed period will be covered by GAA on the replacement appliance Should any person other than an authorized engineer modify or attempt to repair the appliance then the warranty will be invalid The guarantee applies to the UK mainland Scotland Ireland ROI and France but is not transferrable between ...

Страница 23: ...ance is glued grouted or tiled in such a manner that it cannot be removed it is the responsibility of the customer installer to remove and reinstall the appliance to facilitate the repair This Guarantee does not affect your statutory rights The guarantee is offered by GAA Ltd 1301 1303 Lu Plaza 2 Wing Yip St Kwun Tong Kowloon Hong Kong Customer Service To arrange an in guarantee service call pleas...

Страница 24: ... Declaration of conformity CE Declaration of conformity The Manufacturer has a policy of continuous product improvement it reserves the right to adapt and carry out any modification considered necessary without prior warning GHDFF70AL ...

Страница 25: ...25 Appendix Appendix GB IE Installation ...

Страница 26: ...allation Clearance Warning Good ventilation is required around the appliance for easier dissipation of heat and low power consumption Sufficient clearance is required around the appliance The gap between the hob and any cupboard above it should be at least 750mm AB C B D ...

Страница 27: ...he template dimensions with suitable equipment and seal the cut edge with appropriate sealant 12 x 1 T E M P L A T E T E M P L A T E SILIC O N E SILIC O N E 07 Stretch out the supplied seal along the underside edge of the hob ensuring the ends overlap ...

Страница 28: ...28 03 04 Installation 08 x 4 09 x 4 08 09 Note For electrical connection see Technical and legal information section 08 09 30mm 40mm 03 AB C B D AB C B D ...

Страница 29: ...29 Notes ...

Страница 30: ...30 Notes ...

Страница 31: ...31 Notes ...

Страница 32: ...GB IE CNA Trading U K Ltd Hillbrow House Hillbrow Road Esher Surrey KT10 9NW ...

Отзывы: