Owner’s Manual
CAUTION: Read manual carefully for proper procedures and operation.
TRANSIT
Air & Surface Disinfection
Страница 1: ...Owner s Manual CAUTION Read manual carefully for proper procedures and operation TRANSIT Air Surface Disinfection...
Страница 2: ...C technology replicates natural purifying processes by using a high intensity light to activate a proprietary metal catalytic coating converting water vapor into hydrogen peroxide Hydrogen peroxide ac...
Страница 3: ...READ ALL INSTRUCTIONS BEFORE USING THIS PRODUCT WARNING To reduce the risk of fire electrical shock or injury Use only as described in this manual Do not attempt to repair or adjust any of the electri...
Страница 4: ...4 Unit Diagrams Unit Front Air Outlet Filter Unit Back Security Mounting Holes Unit Internals Flush Mounting Bracket Fuse NCC Cell...
Страница 5: ...tion 1 Identify where the unit will be placed Drill hole for wire If needed 2 Attach the unit flush to the surface of the vehicle by using 8 screws to secure the unit in place Connect wiring into the...
Страница 6: ...REASE THE CHANCES OF A THERMAL EVENT For more information in regards to fuses please See section Insert Section 16 2 Gauge wire White Black Positive Charge from Battery 12V 24V CASPR Transit 16 2 Gaug...
Страница 7: ...r injury may occur Make sure the power switch is turned OFF and the unit is unplugged prior to handling 1 Disconnect unit from power source 2 Remove the front cover from the unit by unscrewing the fou...
Страница 8: ...4 Reattach the front cover of the unit 5 Reconnect unit to power source NCC Cell Replacement Your CASPR Transit unit requires replacement of the NCC cells and bulbs every 18 24 months even if the bulb...
Страница 9: ...on page 8 for more information 7 Remove the new Cell Assembly from the packaging box 8 Carefully remove the new bulb from new cell housing DO NOT touch the bulb with bare hands 9 Before replacing the...
Страница 10: ...to power source Fuse Replacement If you find the unit is powered off even after activating the interlock switch and changing the bulb you may need to replace the internal fuse This can be done using t...
Страница 11: ...f your NCC Cell or CASPR TRANSIT fan does not turn on check to ensure a secure connection If secure but the fan is not on it may need to be replaced If the connection is secure but the cell does not l...
Страница 12: ...chnologies s trademarked names images and logos as well as Internet auction sites e g eBay and craigslist To confirm warranty coverage prior to purchasing a product contact CASPR Technologies at 844 7...
Страница 13: ...13 www CASPRTech com 4505 Excel Pkwy Suite 600 Addison TX 75001 844 717 8819 V IN M TR 01 11062021 AE...