Casio DT-930 Series Скачать руководство пользователя страница 1

 
 
 
 
 
 
 

DT-930 

 

Hardware Manual

 

 

(Version 1.00) 

 

 

 

 

 

 

 

 

 

 

 

 

 
 

 

 

 

 

 

 

 

 

 

 

 

CASIO Computer Co., Ltd. 

Copyright ©2006. All rights reserved. 

 

May 2006 

Содержание DT-930 Series

Страница 1: ...DT 930 Hardware Manual Version 1 00 CASIO Computer Co Ltd Copyright 2006 All rights reserved May 2006...

Страница 2: ...r 6 DT 960IOE Basic Cradle 18 6 1 Features at a Glance 18 6 2 External Views 19 6 3 Dimensions and Weight 20 6 4 Hardware Specifications 21 6 5 Electric 23 6 6 Environment 24 6 7 Impact Durability 24...

Страница 3: ...tric 56 9 7 Environment 56 9 8 Impact Durability 56 9 9 Reliability 57 9 10 Compliance 57 Chapter 10 Product Identification and Reference Numbers 58 No part of this document may be produced or transmi...

Страница 4: ...4 Editorial Record Manual Version no Date edited Page Content 1 00 May 2006 Original version...

Страница 5: ...e DT 900 series Supports multi drop protocol communication software used by the DT 700 series Supports FLINK protocol communication software used by the DT 900 series Improved Durability and Resistanc...

Страница 6: ...6 2 External Views 2 1 DT 930M51E Fig 2 1 2 2 DT 930M50E Fig 2 2...

Страница 7: ...7 2 3 DT 964IOE Satellite Cradle 2 4 DT 923LIB Battery Pack Fig 2 3 Fig 2 4...

Страница 8: ...cessories Table 3 2 Item Quantity AA size LR6 alkaline battery 2 pcs Wrist strap 1 pc Desktop guides L and R 1 set Wall mount guides L and R 1 set Backup battery CR2032 1 pc User s guide 1 pc in Engli...

Страница 9: ...e for DT 960IOE 14 pin 25 pin male DT 783RSC RS 232C cable Cross cable for DT 960IOE 14 pin 25 pin female DT 787AX RS 232C cable Cross cable for DT 960IOE 14 pin 19 pin female DT 881RSC RS 232C cable...

Страница 10: ...8 lines 8x16 dots 64 characters 16 digits x 4 lines 8 dot 16x16 dots 32 characters 8 digits x 4 lines 10x10 dots 72 characters 12 digits x 6 lines 10x20 dots 36 characters 12 digits x 3 lines No of c...

Страница 11: ...battery pack x 1 Nominal voltage DC 1 5 V x 2 DC 3 6 V Operating hours Note 1 Approx 200 Approx 50 Operating battery Backup period with only main battery Note 2 5 0 months 1 5 months Battery type But...

Страница 12: ...illustration shows the keyboard viewed from the front on the terminal Two trigger keys are located on the left and right sides ENT F1 F5 F2 F6 F3 F7 F4 F8 SP BL DEL STU VWX YZ JLK MNO POR ABC DEF GHI...

Страница 13: ...ck Static electricity strength Malfunction 5 KV Compliant with EN61000 4 2 Destruction 10 KV Noise radiant intensity CE marking 4 5 Environment Table 4 4 Recommended environment for operation and stor...

Страница 14: ...l brightness Laser scanner 10 000 hours Key Power switch 300 000 times Trigger key 1 000 000 times Right and Left sides Other keys 300 000 times Battery compartment lid 5 000 times Including the lock...

Страница 15: ...se DT 882RSC Cross Cradle 9 pin female side External peripheral 25 pin male side Signal Pin Pin Signal SD 3 2 SD RD 2 3 RD RS 7 4 RS CS 8 5 CS DR 6 6 DR SG 5 7 SG CD 1 8 CD ER 4 20 ER CI 9 22 CI 1 FG...

Страница 16: ...2 IRS OSD 3 3 ISD OSD 4 4 ISD IRD 5 5 ORD IRD 6 6 ORD DT 782RSC Cross Cradle 14 pin female side External peripheral 25 pin male side Signal Pin Pin Signal FG 1 1 FG SD 3 2 SD RD 5 3 RD RS 7 4 RS CS 9...

Страница 17: ...female side Signal Pin Pin Signal FG 1 Case FG SD 3 3 SD RD 5 2 RD RS 7 7 RS CS 9 8 CS CD 13 1 CD ER 8 4 ER DR 11 6 DR SG 14 5 GND FG Case Case FG Fig 5 8 DT 788RSC Cross for RS 485 Signal Pin Pin Si...

Страница 18: ...col for connection to the terminal Also it can supply power to the mounted terminal 6 1 Features at a Glance Casio original protocol optical communication with the terminal Chain links multiple Basic...

Страница 19: ...232C connector RS 485 connector AC adaptor jack EIAJ TYPE3 Power switch DIP switch Power supply terminal Wall mounting unit Rating lable Fig 6 1 Note If this page is not printed properly change the p...

Страница 20: ...0 D mm x 100 H mm Wall mounting configuration 110 W mm x 220 D mm x 110 H mm Weight Approx 355 g see notes Notes If the hook and cover for wall mounting are used the product weight is increased by app...

Страница 21: ...Method Half duplex Data length 8 bits Stop bit 1 Data format Parity bit none Baud rate bps 2400 9600 19 2K 38 4K 57 6K 115 2K Mark 15 to 5V SD Space 15 to 5 V Mark 3 V or less I F level RD Space 3 V...

Страница 22: ...position OFF Termination At the end position ON Switch 7 Yes OFF Chain connection No ON No 8 is not used DIP switch setting default at factory No 1 OFF No 5 OFF No 2 ON No 6 ON No 3 OFF No 7 OFF DIP s...

Страница 23: ...adaptor DT 9020ADP U AC100 120V 50 60Hz Input conditions Voltage 10 of rated voltage Frequency 1Hz of rated frequency Line noise Malfunction at 700V Pulse width 100 to 800 nsec Cycle 10 to 35 msec var...

Страница 24: ...l impact 1 Kg at 6 specified positions Overall impact 20 Kg Resistance to vibration 0 15 G Conditions In X Y Z directions 10 to 55 Hz 30 minutes 6 8 Reliability Table 6 6 Item Specification MTBF 67 00...

Страница 25: ...asic Cradle and Host P C with external device connected HOST PC DT 930 Basic Cradle RS 232C IR communication 115 2 Kbps max 115 2 Kbps max Fig 6 2 DIP Switch Setting Table 6 8 No Use of Switch Destina...

Страница 26: ...At middle Termination 115 Kbps max IR comm 115 Kbps max IR comm 115 Kbps max Configuration Example A Configuration Example B DIP Switch Setting Table 6 9 Setting No Use of Switch Destination Switch RS...

Страница 27: ...tting No Use of Switch Destination Switch Middle of chain End of chain Remark 1 Baud rate switching 0 To GA IRSPEED0 ON ON 2 Baud rate switching 1 To GA IRSPEED1 OFF OFF 3 Baud rate switching 2 To GA...

Страница 28: ...4 5 6 Max 1 m Modular plug 6 6 6 FR SYK 1 2 3 4 5 6 Cable see Table 10 13 Fig 6 5 Table 6 11 Cable Conductive 20 0 1 A Insulation Semi rigid P V C Core wire Finish form 20 0 1 A Insulation P V C Shea...

Страница 29: ...ove 1 2 3 4 5 6 Max 1 000 m Modular plug 6 6 6FR SYK 1 2 3 4 5 6 Cable SK UTP 100M3P Fig 6 7 Wiring of the cable cross and twist pair Cradle at downstream side Cradle at upper stream side Pin no Signa...

Страница 30: ...easuring equipment etc a radio or television receiver or wireless equipment If cables are routed near such a piece of equipment it may be subject to electrical interference Precautions to be observed...

Страница 31: ...he terminal Chain links multiple Satellite Cradles The integrated RS 422 driver receiver is used to connect a maximum of eight units of DT 964IOE with a total cable length of 1 Km Power supply capabil...

Страница 32: ...AC adaptor jack EIAJ TYPE4 Wall mounting unit DIP switch RS 422 connector C OUT side Charging power supply terminal Lithium Ion battery pack charging compartment Rating label Fig 7 1 Note If this pag...

Страница 33: ...20 D mm x 100 H mm Wall mount configuration 110 W mm x 220 D mm x 110 H mm Weight 500 g approx see notes Notes If the hook and cover for wall mounting are used the product weight is increased by appro...

Страница 34: ...none Fixed Baud rate bps 9600 38 4K 115 2 K Bit switch setting of IrCOMM Mark LED off I F level Space LED on pulse width 1 6 usec approx On pulse width is fixed irrespective of the ransmission rate I...

Страница 35: ...I No 6 RDO 6 wire modular connector Chain I F Usage example Basic Cradle Switch no 1 2 38 4 Kbps OFF OFF 115 2 Kbps ON OFF No setting OFF ON Host PC I F baud rate setting Setting prohibited ON ON Swit...

Страница 36: ...G2 LED OK OFF Communication braked NG Red OK Green flashing DATA While communicating NG Red 2 color LED DATA LED Not used Negotiation OFF Indicatio n LINE During use Red LINE LED Input voltage DC12V 5...

Страница 37: ...used R Power supply Terminal block Layout of terminals Charging terminal C 7 5 Electric Table 7 3 Item Specification Remark Power consumption 7 2 W With applicable AC adaptor Available power supply DC...

Страница 38: ...1 Kg at specified position Overall impact 20 Kg Resistance to vibration 0 15 G Conditions in X Y Z directions 10 and 55 Hz 30 minutes 7 8 Reliability Table 7 6 Item Specification MTBF 48 000 hours Po...

Страница 39: ...rk Radio interference EN55022 1994 A2 1997 Class B CISPR Pub 22 1993 A2 1996 Class B Tested with AD S42120AE Electromagnetic compatibility generic immunity EN50082 1 1997 Tested with AD S42120AE Safet...

Страница 40: ...ching 1 DT 930 and Cradle To GA to CPU PB7 IRSPEED1 OFF 115 2Kbps Note 1 3 Mode switching 0 To GA to CPU PA13 MODE0 OFF 4 Mode switching 1 To GA to CPU PA14 MODE1 OFF Active operation 5 Termination sw...

Страница 41: ...aud rate switching 1 DT 930 and Cradle To GA to CPU PB7 IRSPEED1 OFF OFF 115 2Kbps Note 1 3 Mode switching 0 To GA to CPU PA13 MODE0 ON ON 4 Mode switching 1 To GA to CPU PA14 MODE1 OFF OFF Passive Op...

Страница 42: ...PB6 IRSPEED0 ON ON ON 2 Baud rate switching 1 DT 930 and Cradle To GA to CPU PB7 IRSPEED1 OFF OFF OFF 115 2Kbps Note 1 3 Mode switching 0 To GA to CPU PA13 MODE0 OFF ON ON 4 Mode switching 1 To GA to...

Страница 43: ...A to CPU PB7 IRSPEED 1 OFF OFF OFF 115 2Kbps Note 1 3 Mode switching 0 To GA to CPU PA13 MODE0 OFF ON ON 4 Mode switching 1 To GA to CPU PA14 MODE1 ON OFF OFF 5 Termination switching To GA to CPU PA15...

Страница 44: ...1 A Insulation Semi rigid P V C Core wire Finish form 20 0 1 A Insulation P V C Sheath Finish O D 4 3 0 1 mm Conductive resistance 0 12 ohm m or less Characteristics Insulation resistance 50 Mohm or g...

Страница 45: ...K50 1 2 3 4 5 6 Cable SK UTP 100M3P Fig 7 8 Wiring of the cable straight connection pin to pin Cradle at downstream side Cradle at upper stream side Pin no Signal Pin no Signal 1 IRS 1 ORS 2 IRS 2 ORS...

Страница 46: ...short circuit damaging proper communication Do not route cables near precision equipment measuring equipment etc a radio or television receiver or wireless equipment If cables are routed near such a...

Страница 47: ...unication by CASIO original protocol Capability of supplying power to DT 930 The built in circuit has a capability of supplying power to the mounted terminal when the dedicated AC adaptor AD S15050A i...

Страница 48: ...48 8 2 External Views Fig 8 1 Note If this page is not printed properly change the printer graphic property from Vector Graphic to Raster Graphic...

Страница 49: ...rms to Version 1 1 Synchronizatio n Asynchronous Frame synchronous Method Half duplex I F to DT 930 Baud rate bps 4Mbps MAX Protocol USB Ver 1 1 conformity Baud rate bps 12Mbps MAX 1 2 4 3 USB connect...

Страница 50: ...H Humidity Storage 10 to 90 RH No condensation Contact 6 KV Electrostatic Non contact 8 KV Conditions 150 pF 330 ohm 8 7 Impact Durability Table 8 5 Item Specification Remark Shock proof height of fal...

Страница 51: ...51 8 9 Compliance Table 8 7 Standard Remark EN55022 1998 A1 2000 A2 2003 Class B EN55024 1998 A1 2001 A2 2003 EN61000 3 2 2000 EMC EN61000 3 3 1995 A1 2001...

Страница 52: ...t a Glance Charging battery pack and supplying power to DT 930 It has integrated charge circuit to charge the battery pack and to supply power preventing battery s power being consumed by the terminal...

Страница 53: ...adaptor jack EIAJ Type 3 Wall mounting unit Charging po wer supply terminal Lithium Ion battery pack charging compartment Rating label Fig 9 1 Note If this page is not printed properly change the prin...

Страница 54: ...mm x 220 D mm x 110 H mm Weight Approx 390 g see notes Notes If the hook and cover for wall mounting are used the product weight is increased by approximately 10 g If the nose guide for straight open...

Страница 55: ...9020ADP G Input AC230V Applicable AC adaptors DT 9020ADP U Input AC120V Specification BC 9801C Input voltage 6 5 to 15 V Power consumption 5 VA or less DT 923LIB Rated voltage 3 6 V Battery pack Rated...

Страница 56: ...ADP U 3 5mA or less Leak current DT 9020ADP G 1mA or less Terminal noise voltage Conform to EN55022 Tested with AC adaptor DT 9020ADP G Noise radiation electric field Conform to EN55022 Tested with AC...

Страница 57: ...moving the battery pack in from the compartment 5 000 times Notes The above MTBF figure has been calculated based on each MTBF of the electronic parts employed The above figure does not apply to the A...

Страница 58: ...present identification and references of each terminal The numbers from 10 to 15 represent a manufacturing reference which is reserved by the manufacturer See the figure below for each meaning 1 2 3 4...

Отзывы: