— 9 —
3) Equipment connection/Procedure
ADJUSTMENT
MAIN PCB
1) Items to be adjusted:
2) Adjustment and Test Point Locations
Item
Measuring Instrument
Vop voltage setting
Voltmeter
TP2
(Top View)
(Bottom View)
VR1
Vop voltage setting
Watching the LCD at a 41.20
°
angle to the horizontal, adjust Vop
voltage so that unenergized segments are seen dimly.
Output
Set
Voltmeter
TP2
41.20
°
LCD
Eye
Input
Connection
Input
Point
Input
Signal
Adjust
Output
Connection
Output
Point
Adjust for
VR1
Voltmeter
TP2
Adjust for 4.2 ~ 4.3 V reading
on voltmeter under the tem-
perature 20 ~ 25
°
C.
Make fine adjustment accord-
ing to the following instruc-
tion.
Содержание CTK-485
Страница 12: ...11 PRINTED CIRCUIT BOARDS Main PCB JCM450 MA1M Top View Bottom View 1 2 7 5 3 4...
Страница 13: ...12 Keyboard PCB KDM6111K KY1M Keyboard PCB KDM6111K KY2M Main PCB JCM450 MA2M 6 8 9 10...
Страница 14: ...13 SCHEMATIC DIAGRAMS Main PCB JCM450 MA1M 1 2 7 5 3 4...
Страница 15: ...14 Main PCB JCM450 MA2M 8 6 9 10 2 9 V 5 3 V 0 7 V...
Страница 17: ...16 EXPLODED VIEW 13 14 9 8 6 15 18 5 12 4 17 6 1 19 10 11 3 2 7 16 R 1 R 2 R 4 R 5 R 6 R 3 R 6 R 5...