Casio 2782 Скачать руководство пользователя страница 1

Operation Guide 2782

1

MO040

7

-EB

Getting Acquainted

Congratulations upon your selection of this CASIO watch. To get the most out
of your purchase, be sure to carefully read this manual and keep it on hand
for later reference when necessary.

Applications

The built-in sensors of this watch measure altitude, barometric pressure,
temperature and underwater depth. Measured values are then shown on the
display. Such features make this watch useful when hiking, mountain
climbing, skin diving, or snorkeling, or when engaging in other such outdoor
activities.

For a watch with the elapsed time bezel

Rotate the elapsed time bezel to align the 
mark with the minute hand.
After that, the number of minutes that elapse is
indicated by how far the minute hand has moved
from 

.

Elapsed time bezel

Warning!

The measurement functions built into this watch are not intended for
taking measurements that require professional or industrial precision.
Values produced by this watch should be considered as reasonable
representations only.

This watch is intended for use up to skin diving and snorkeling. Never
use this watch while scuba diving.

Never operate the buttons of the watch while underwater.

CASIO COMPUTER CO., LTD. assumes no responsibility for any loss,
or any claims by third parties that may arise through the use of this
watch.

About This  Manual

Button operations are indicated using the
letters shown in the illustration.

Each section of this manual provides you with
the information you need to perform operations
in each mode. Further details and technical
information can be found in the “Reference”
section.

Most of the display examples in this manual
show only the digital display, without the analog
hands, as shown in the lower illustration.

(Light)

Timekeeping Mode

Barometer/

Thermometer Mode

Depth Gauge Mode

Press 

B

.

From the Timekeeping Mode, you can press 

B

 to directly enter the

Barometer/Thermometer Mode or 

D

 to enter the Altimeter Mode. You can

also use 

B

 and 

D

 to switch between the Barometer/Thermometer Mode

and the Altimeter Mode.

General Guide

The illustration below shows which buttons you need to press to navigate
between modes.

In any mode, press 

L

 to illuminate the display.

Countdown

Timer Mode

Stopwatch Mode

C

Altimeter Mode

C

Press 

C

.

Press 

D

.

Alarm Mode

Hand Setting Mode

C

Press 

C

.

C

C

Timekeeping

This watch features separate digital and analog
timekeeping. The procedures for setting the
digital time and analog time are different.

Whenever you need to adjust both the digital
and the analog time settings, make sure you
adjust the digital setting first.

Digital Time and Date

Use the Timekeeping Mode to set and view a
digital display of the current time and date. When
setting the digital time, you can also configure
settings for the 12/24-hour format.

Hour : Minutes

PM indicator

Seconds

Month – Day

Day of week

To set the digital time and date

1. In the Timekeeping Mode, hold down 

A

 until the seconds start to flash,

which indicates the setting screen.

2. Press 

C

 to move the flashing in the sequence shown below to select other

settings.

Year

Seconds

Hour

Minutes

Day

Month

12/24-Hour
Format

4. Press 

A

 to exit the setting screen.

Note

Resetting the seconds to 

00

 while the current count is in the range of 30 to

59 causes the minutes to be increased by 1. In the range of 00 to 29, the
seconds are reset to 

00

 without changing the minutes.

With the 12-hour format, the 

P

 (PM) indicator appears on the display for

times in the range of noon to 11:59 p.m. and no indicator appears for times
in the range of midnight to 11:59 a.m.

Setting

Seconds

Hour, Minutes

12/24-Hour
format

Year, Month,
Day

Button Operations

Press 

D

 to reset the seconds to 

00

.

Use 

D

 (+) and 

B

 (–) to change the setting.

Use 

D

 to toggle between 12-hour (

12H

)

and 24-hour (

24H

) timekeeping.

Use 

D

 (+) and 

B

 (–) to change the setting.

Screen

3. When the setting you want to change is flashing, use 

D

 and/or 

B

 to

change it as described below.

With the 24-hour format, times are displayed in the range of 0:00 to 23:59,
without any indicator.

The 12-hour/24-hour timekeeping format you select in the Timekeeping
Mode is applied in all modes.

The year can be set in the range of 2000 to 2039. The day of the week is
calculated automatically in accordance with the date you set.

The watch’s built-in full automatic calendar automatically makes allowances
for different month lengths and leap years. Once you set the date, there
should be no reason to change it except after you have the watch’s battery
replaced.

Содержание 2782

Страница 1: ...ween modes In any mode press L to illuminate the display Countdown Timer Mode Stopwatch Mode C Altimeter Mode C Press C Press D Alarm Mode Hand Setting Mode C Press C C C Timekeeping This watch features separate digital and analog timekeeping The procedures for setting the digital time and analog time are different Whenever you need to adjust both the digital and the analog time settings make sure...

Страница 2: ...ric pressure history graph A rising graph generally means improving weather A falling graph generally means deteriorating weather About Barometric and Temperature Measurements Barometric pressure and temperature measurement operations are performed as soon as you enter the Barometer Thermometer Mode After that barometric pressure and temperature measurements are taken every five seconds for the fi...

Страница 3: ...esigned to start depth measurement and record data in memory after a depth of 1 meter 4 feet is reached Because of this the explanations in this User s Guide uses the term submerged to refer to any depth deeper than 1 meter and the on the surface to refer to any depth shallower than 1 meter Leaving the watch in the Depth Gauge Mode while not in the water consumes battery power Exit the Depth Gauge...

Страница 4: ... stored in memory To view log data 1 While in the Timekeeping Mode press C to enter the Depth Gauge Mode 2 Press B to cycle through the data screens in the sequence shown below If you do not perform any button operation for about five or six seconds while a Log Data screen is on the display the watch will automatically return to the Depth Gauge Mode screen Maximum depth Water temperature at maximu...

Страница 5: ...ntil you stop it by pressing any button To test the alarm In the Alarm Mode hold down D to sound the alarm To turn an alarm and the Hourly Time Signal on and off 1 In the Alarm Mode use D to select an alarm or the Hourly Time Signal 2 When the alarm or the Hourly Time Signal you want to is selected press B to turn it on and off Indicates alarm is ON Indicates Hourly Time Signal is ON The alarm on ...

Страница 6: ... mind when diving at high altitudes or in fresh water Answer The depth reading is automatically reset to 0 0 m 0 ft whenever the Depth Gauge Mode is entered so you can use this watch for skin diving at altitudes Note however that malfunctions occur when skin diving at altitudes greater than approximately 4 000 meters 13 000 ft In addition as this watch bases its calculations on sea water which has...

Страница 7: ...OFF or a barometric pressure value if set If a barometric value is set the display goes blank for four or five seconds and then the currently set pressure value appears l l l l l l l l l l l l l l If OFF or a value does not appear in the upper and lower parts of the display press A again to exit the setting screen and repeat step 2 of this procedure 3 After waiting four or five seconds press C to ...

Страница 8: ... This is the setting screen Wait for four or five seconds before performing step 3 below If you don t wait there is the chance of setting value error If the display went blank in step 2 the current reference value will appear flashing on the display after the four or five seconds pass If OFF or the current reference altitude value does not appear at this time press A to return to the Altimeter Mod...

Отзывы: