Xiamen Cashino Technology Co.,Ltd
A2L User Manual
43
7
0 00
0
Fexed to be 0
Unrecoverable error: abnormal input voltage
Automatic recovery error: refers to the printing head overheating error.
When the printing head overheating error occurs, wait for a period of
time.When the printing head temperature drops, the error will be
automatically recovered.
n=4
:
paper sensor status
bite 0
/
1
Hexadecim
al
decimalis
m
Function
0
0 00
0
Fixed to be 0
1
1 02
2
Fixed to be 1
2
,
3 0 00
0
Paper
1 0C
12
Paper near-end
4
1 10
16
Fixed to be 1
5
,
6 0 00
0
Paper
1 60
96
Paper end
7
0 00
0
Fixed to be 0
Example
10 04 01
10 04 02
10 04 03
10 04 04
⑦
Two-dimensional bar code commands
Mode type of QR code
Name
Mode type of QR code
Code
ASCII
:
GS (
k
pL pH cn fn n
Decimal
:
29
40
107 pL pH cn fn n
Hexadecimal
:
1D 28
6b pL pH cn fn n
Function
Setting mode type of QR code to [n dot × n dot].
Range
pL=3, pH=0
cn=49
fn=67
0 ≤ n ≤ 16
Defaults
n=3