CSN-A1 user manual
50
Decimal
:
29
40
107 pL pH cn fn n
Hexadecimal
:
1D 28
6b pL pH cn fn n
Function
Setting mode type of QR code to [n dot × n dot].
Parameter
range
pL=3, pH=0
cn=49
fn=67
0 ≤ n ≤ 16
Default
n=3
Notes
Setting mode type of QR code to [n dot × n dot].
Example
None
Name
Mode type of QR code
Setting error correction level of QR code
Name
Setting error correction level of QR code
Code
ASCII
:
GS (
k
pL pH cn fn n
DEC
:
29
40
107 pL pH cn fn n
HEX
:
1D 28
6b pL pH cn fn n
Function
Setting error correction level of QR code
Parameter
range
pL=3, pH=0
cn=49
fn=69
48 ≤ n ≤ 51
Default
n=48
Notes
Setting error correction level of QR code
n
Function
Approximate Amount of
correction
4
8
Error correction level (L)
7%
4
9
Error correction level (M)
15%
5
0
Error correction level(Q)
25%
5
1
Error correction level (H)
30%
Example
None
Name