MODEL C-CS

“CLEAN STEAM”

PRESSURE REDUCING REGULATOR

SECTION l

INSTALLATION, OPERATION, & MAINTENANCE MANUAL

I.  DESCRIPTION AND SCOPE

Model C-CS is a pressure reducing regulator used to control down stream (outlet or P

2

) pressure. Inlet and outlet 

sizes are 3/4" (DN20), 1" (DN25), 1-1/2" (DN40), 2" (DN50) and 3" (DN80) with Tri-Clamp

®

 fitting connections. This 

regulator is primarily designed for steam service at tem per a tures equal to or less than 366°F (185°C); this cor re sponds 
to 150 psig (10.3 Barg) sat u rat ed steam; however, the unit may also be used for clean gaseous or liquid applications.

SECTION II

II. INSTALLATION

1.  An inlet block valve should always be in stalled.

2.  If service application is continuous such that 

shutdown is not readily accomplished, it is 
recommended that inlet and outlet block valves 
and a manual bypass valve be in stalled.

3.  An outlet pressure gauge should be lo cat ed 

ap prox i mate ly ten pipe diameters down stream 
and within sight.

4.  All installations should include a down stream 

re lief device if the inlet pressure could exceed 
the pressure rating of any down stream 
equip ment.

5.  Flow Direction: Install so the flow enters 

through the bottom connection and exits the 
side connection.

6.  Install in a well drained  pipe, properly  trapped, 

with spring chamber (2) in the vertical position 
to allow for proper drain ing.

7.  For insulated piping systems, the regulator 

should not be insulated.

SECTION III

III. PRINCIPLE OF OPERATION

1.  Movement occurs as pressure variations 

reg is ter on the diaphragm. The registering 
pres sure is the outlet, P

2

 or down stream 

pressure. The range spring opposes di a phragm 
move ment. As the outlet pressure drops, the 
range spring pushes the diaphragm down, 

The Model C-CS should never be used as a shut-off  device.

CAUTION

Do not apply spring load or operate regulator with 
hitch pin (21) removed from top of guide post (27 ).  
Pre ma ture di a phragm failure will re sult.

CAUTION

Installation of adequate overpressure protection 
is recommended to protect the regulator from 
overpressure and all downstream equipment from 
damage in the event of regulator failure.

CAUTION

Inlet

@  P

1

Outlet
@  P

2

SRV

Bypass

(Recommended Piping Schematic for Pressure Reducing Station)

Model C-CS

Reducing Regulator

Blowdown Drain

Blowdown Drain

ISO Registered Company

Содержание C-CS

Страница 1: ...ld exceed the pressure rating of any downstream equipment 5 Flow Direction Install so the flow enters through the bottom connection and exits the side connection 6 Installinawelldrained pipe properly...

Страница 2: ...ent is in operation 8 Continue to slowly open the inlet upstream block valve until fully open 9 Continuetoslowlyopentheoutlet downstream block valve When flow is established steady enough that the out...

Страница 3: ...iece Secure winged end of stem 14 1 in a soft jawed vise Use the flats on the pressure plate to rotate CCW to remove pressure plate assembly 10 Lay pressure plate assembly 27 28 and 29 and aside NOTE...

Страница 4: ...diaphragm 17 O ring 16 diaphragm gasket 15 and body 1 11b For Model C CS with Opt 11 Removediaphragm 17 diaphragmgaskets 15 O ring 18 seal 19 pusherplate 20 O ring 16 and body 1 12 Inspectplug 14 and...

Страница 5: ...ude minimum trim replacement parts needed plus those Soft Goods parts from column A If the BOM is not available refer to the cross sectional drawings included in this manual for part identification an...

Страница 6: ...20 Pusher Plate 21 Hitch Pin 1 Refer to Figure 1 for Clamp and related item numbers Item No Description Kit A Kit B 25 Upper Guide Assembly 25 6 Adjusting Screw 25 7 Adjusting Screw Cap 25 8 Dowel Pin...

Страница 7: ...IOM C CS 7 See the previous page for Item Number and Descriptions Figure 4 Option 11 Diaphragm Restraint Barstock Body Only Figure 3 Investment Cast body...

Страница 8: ...The details of the assessment in terms of the individual Essential Health and Safety Requirements are listed in Table 1 Table 2 lists all of the models and options that were evaluated and along with...

Страница 9: ...low the same requirements for the piping system Also see item 30 in Table 1 2 The system designer and users must take precautions to prevent rapid system pressurization which may raise surface tempera...

Отзывы: