CAS PD-I Скачать руководство пользователя страница 1

 

One Blue Hill Plaza, 16

th

 Floor, PO Box 1546 

Pearl River, NY 10965 

1-800-PC-AMERICA, 1-800-722-6374 

(Voice) 845-920-0800 (Fax) 845-920-0880 

 

 

1 | 

P a g e

 

 

Setting up the CAS PD-I 

 

 

 

 

 

 

 

 

This document contains step-by-step instructions for setting up the CAS PD-I to work with CRE. 

To connect the CAS PD-I to your computer, you need the following cable: 

The CAS Part Number is: JPDB SHARP RS232 7880-PD0-4134 or IBM 7880-PD0-4128 

Содержание PD-I

Страница 1: ... 845 920 0800 Fax 845 920 0880 1 P a g e Setting up the CAS PD I This document contains step by step instructions for setting up the CAS PD I to work with CRE To connect the CAS PD I to your computer you need the following cable The CAS Part Number is JPDB SHARP RS232 7880 PD0 4134 or IBM 7880 PD0 4128 ...

Страница 2: ...ake sure the scale are certified and weighing items properly 1 Remove the calibration bolt and plate 2 You will see three black micro switches Press and hold down SW3 3 Plug the scale in and turn it on The power button is located underneath the scale to the right of the micro switches 4 The weight display will flash CAL three times After this occurs release SW3 You should see A d 1 on the display ...

Страница 3: ...ard enough to be able to safely place 30 lb or 15 kg on the platter 6 Make sure there is nothing on the platter and press SW3 three times You should see CAPA and a number on the display This number determines the scale s capacity CAPA CAPACITY 0 6 x 0 002 lb 3 x 0 001 kg 1 15 x 0 005 lb 6 x 0 002 kg 2 30 x 0 01 lb 15 x 0 005 kg 7 Press SW4 to change the capacity and SW5 once you have selected a ca...

Страница 4: ...ed 0 Kilograms kg 1 Pounds lb 9 Press SW4 to change the unit and SW5 once you have selected a unit 10 You should see tyPE and a number on the display This number determines the scale s interface type Press SW4 until the number is 5 11 Press SW5 End will be displayed CAL will flash three times and then A d1 will be displayed ...

Страница 5: ... and place the platter properly on the platform 13 Turn the scale on 14 If all went well the scale will do a test cycle and display 0 00 If this does not occur turn the scale off remove the platter and repeat steps 2 13 until it does ...

Страница 6: ...6 P a g e 15 Remove the platter 16 Replace the calibration bolt and plate 17 Replace the platter ...

Страница 7: ...PD I to your computer you need the following cable The CAS Part Number is JPDB SHARP RS232 7880 PD0 4134 or IBM 7880 PD0 4128 Turn off your computer and follow these steps 1 Find the serial port on your computer 2 Plug the serial cable connected to the scale into the port ...

Страница 8: ...tup and then Setup Screen 2 Select the Hardware tab 3 Select the COM port that the scale is connected to Many systems have labels on the ports that contain this information If yours does not select COM 1 You may need to select other COM ports later if CRE does not find the scale Enter the optional tare amount Leave at 0 if you do not want to use a tare 4 Select CAS PD I or PD II for Primary Scale ...

Страница 9: ...9 P a g e 5 Select Page 2 6 Select the radio button next to 30x 01 lb under Scale Weight Formatting 7 Select Scale 8 Activate the scale feature and select Done 9 Select Update ...