background image

BI Series

Weighing Indicator

OWNER’S MANUAL

Содержание BI-100D

Страница 1: ...BISeries Weighing Indicator OWNER S MANUAL ...

Страница 2: ...IFICATIONS 5 PARTNAMEANDFUNCTION 5 SYSTEMMODE 7 GENERALFUNCTION DESCRIPTION 13 CONVERSIONMODE 15 RS 232CCOMMUNICATION 15 INSTALLING 18 USING KEEPING 19 BATTERY 19 TESTFUNCTION 21 CALIBRATIONMODE 23 SEALING OPTIONALDRAWING 26 ERRORMESSAGEDESCRIPTION ANDMANAGEMENT 27 ...

Страница 3: ... exposed directly to the sun and including much dust Do not use in the place with excessive electrical noises and shaking Charge a battery in full to use after negligence for a long time Install the platform on a flat place FEATURES Simple outdoor using in use of battery Using general Mn Alkaline battery or rechargeable battery Easy operation and various functions SPAC Single pass automatic span c...

Страница 4: ... of Max Capacity 1 V D more 1 100 000 MAX 1 10 000 MAX Maximum capacity 5 place LCD Char size 23 5mm 1 Stable 2 High Normal Low HI OK LO 3 Battery discharge BAT 4 quantity unit PCS 5 Weight unit kg lb Approx 0 15W Part name and function Part name Lcd Display Loadcell Contact output RS232C key Top cover Bottom Cover Adapter connector OPTIONAL BI 100D BI 100R BI 100DB BI 100RB DC1 5V 6EA Mn battery ...

Страница 5: ...current weight exceeds normal weight lamp ON when the current weight is normal lamp ON when the current weight is 80 90 of normal weight lamp ON when the current weight is 50 80 of normal weight lamp ON when the current weight is below 50 of normal weight 6 Display part kg lb pcs HI OK LO B A T KEY PART KEY FUNCTIONS KEY Use to power ON OFF KEY Use in case of rezero within 2 of max capacity or to ...

Страница 6: ...comparing mode Determine that the weight is high normal or low value and perform the display Count mode Display the quantity by setting the unit or sample weight Quantity comparing mode Perform the display after discrimination by setting High Low quantity MODE CONVERSION Press key for 2 sec to display the following message kg LO Execute depending on the below mode conversion and setting method DIG...

Страница 7: ... 3 Step 4 Step 5 Step 6 ENTER MODE Press once Set to 0 Press twice Input 2 as the first place value Press once Move to the left by one place Press once Decimal point input Press five times Input 5 as the first place value Input completion SIMPLE WEIGHING MODE CONVERSION DISPLAY KEY PLATFORM DESCRIPTION Step 1 Step 2 Press once Press once Generally operated ENTER Empty LO kg ENTER MODE ...

Страница 8: ...e of no resetting the High Low value In case of resetting the High Low value DISPLAY KEY PLATFORM DESCRIPTION Step 1 Step 2 Step 3 Step 4 Step 5 Step 6 Press twice Press once Low weight input Refer to digit input in page 8 High value input Refer to digit input in page 8 Generally operated ZERO MODE Empty kg LO LO pcs pcs kg kg kg kg kg kg kg LO ...

Страница 9: ...ge of unit weight Min Division DISPLAY KEY PLATFORM DESCRIPTION Step 1 Step 2 Step 3 Step 4 Step 5 Press three times Press once Display the set weight Input the unit weight Press Mode key to round and display unit weight Generally operated kg kg pcs pcs kg kg pcs MODE MODE MODE Set digit input in page 8 Step 5 Ex Min division is 0 1 Input the unit weight as 0 532 and round off the second place of ...

Страница 10: ...five times Simple count input 50pcs Press once Press once with platform loaded Unit weight display Press once Generally operated ENTER Empty Empty Empty Sample In case of setting the unit weight by sample Samples 10 200 10 unit pcs pcs kg pcs MODE MODE ENTER ENTER Note For setting the unit weight by sample count the min unit weight shall be more than min division ...

Страница 11: ... setting the High Low quantity DISPLAY KEY PLATFORM DESCRIPTION Step 1 Step 2 Step 3 Step 4 Step 5 Step 6 Press four times Press once Low value setting Low value input Press once High value setting Press once High value input Press once Generally operated kg kg pcs pcs pcs pcs pcs LO kg kg kg kg kg kg MODE MODE MODE Set digit input in page 8 pcs pcs pcs LO Set digit input in page 8 Empty ...

Страница 12: ...eed the maximum capacity kg Put the TARE on platform TARE weight 10kg kg Press TARE key The TARE weight is saved kg Put the object on platform object weight 20kg In case to want know the Gross weight kg Press NET GROSS key object TARE weight display In case to want know the Net weight kg Press NET GROSS weight key object weight display Remove the TARE and object from platform to display the saved ...

Страница 13: ...s displayed To release the hold weight Empty the platform or press Hold key and perform the normal operation Auto hold function release kg Empty the platform kg Press Hold key Auto hold release message is shown for 1 sec and then normally operated Hold lamp is OFF Manual hold function Executed at pressing Hold key kg Put the object 10kg on platform kg Press Hold key Hold message is displayed for 1...

Страница 14: ...is used to spare the battery by means of power off when this scale is not used Set point Meaning Auto power OFF is not used Automatically power off when the weight is not changed or no key is used for 5 min F 1 0 F 1 1 F 2 RS 232C communication setting option Set point Meaning No transmit Transmit at both stable and unstable weight Transmit at stable weight Transmit at data request Data request si...

Страница 15: ...DICATOR RS 232C port Computer serial 9 pin port RS 232C Output data format Baudrate 9600bps Data bit 8 Stop bit 1 Parity bit None Code ASCII Transmit data format Total 22 bytes K G CR LF L B data 8bytes US Unstable ST Stable OL Overload GS GROSS W NT NET W Empty Lamp status byte Empty Weight unit Lamp status byte Display the current state ON OFF of indicator lamp bit7 bit6 bit5 bit4 bit3 bit2 bit1...

Страница 16: ... THEN 20 70 PRINT B 80 PRINT 1 B 90 GOTO 20 Simple transmit receive program C Language include bios h include conio h define COM1 0 define DATA_READY Ox100 define TRUE 1 define FALSE 0 define SETTING 0x00 0xE0 0x00 0x03 int main void int in out status DONE FALSE bioscom 0 SETTING COM1 cprintf BIOSCOM ESC to exit n while DONE status bioscom 3 0 COM1 if status DATA_READY if out bioscom 2 0 COM1 0x7F...

Страница 17: ... be different by loadcell production company and model Loadcell color table by company Company Connector CAS BONGSIN JEANGWOO KYOWA INTERFACE P T BLS SHOWA SHINKOH TMI TML TFAC HUNTLEIGH No 1 No 2 No 3 No 4 No 5 EX EX SIG SIG SHIELD RED WHITE GREEN BLUE EXTERNAL RED WHITE GREEN BLUE YELLOW RED WHITE GREEN BLUE YELLOW RED BLACK GREEN WHITE EXTERNAL RED BLACK GREEN WHITE EXTERNAL RED BLACK GREEN WHI...

Страница 18: ...BATT RECH DRY GND NO RELAY CN3 IN EX EX CN2 RS232 KEEPING Power off by pressing ON OFF key Open the top cover and power off for a long time storage BATTERY Battery replacement or charging time Power is off in a specific time after BAT signal flickers in the left bottom of display part on using Replace the general battery or charge the rechargeable battery General Mn Alkaline battery using and repl...

Страница 19: ... ON When the battery is charging RED lamp is ON at charge lamp part When the charging is completed GREEN lamp is ON at charge lamp part It takes approximately 4 5 hours to charge in full A d a p t e r DRY RECH G N D NO C RELAY CN3 BATT CN4 DRY RECH BATT CN4 IN CN2 RS232 EX EX Battery using period Conditions Using period BACK LIGHT E L is not used BACK LIGHT E L is always used Recharging battery Ap...

Страница 20: ...start TEST 1 Function LCD TEST Used key LCD screen Description ENTER key Press once Test running Press one more time Next menu Display TEST 1 state kg lb pcs HI OK LO B A T Used key LCD screen Description ENTER key Press once Test running Press one more time Next menu Display TEST 2 state Display the digital value corresponding to current weight Used key LCD screen Description ENTER key Press once...

Страница 21: ...computer keyboard and check that 1 is shown in LCD screen of indicator and check that the next ASCII code value 2 is inputted in computer ASCII code table Char Code Char Code Char Code Char Code Char Code Char Code 32 0 48 64 P 80 96 p 112 33 1 49 A 65 Q 81 a 97 q 113 34 2 50 B 66 R 82 b 98 r 114 35 3 51 C 67 S 83 c 99 s 115 36 4 52 D 68 T 84 d 100 t 116 37 5 53 E 69 U 85 e 101 u 117 38 6 54 F 70 ...

Страница 22: ... ZERO TEST TARE CAL message and pressing Tare key moves into CAL 1 Calibration menu CAL 1 CAL 5 CAL 1 Maximum capacity setting CAL 2 Minimum division setting CAL 3 Span weight setting CAL 4 Zero calibration CAL 5 Span calibration Digit input method Increase the first place value by 1 Move to the left by 1 place Set the inputted value to 0 Move to the next menu ZERO ENTER Ex 150 input key Press onc...

Страница 23: ...ve to the next menu 0 001kg 0 5kg CAL 2 Function Minimum Division setting Setting range from 0 001kg to 50kg Min Min Min Min Min division division division division division 1 0 001kg 4 0 01kg 7 0 1kg 10 1kg 13 10kg 2 0 002kg 5 0 02kg 8 0 2kg 11 2kg 14 20kg 3 0 005kg 6 0 05kg 9 0 5kg 12 5kg 15 50kg Used key LCD screen Description Input by digit input method ENTER key Move to the next menu Set the ...

Страница 24: ...menu after span calibration Empty the platform and when LCD screen shows ULOAD press ENTER key Then move into span calibration after counting down from 5 Reference 1 Zero calibration is performed automatically by program Loadcell output is automatically adjusted within 0 05mV and 5mV CAL 5 Auto span calibration takes about 30 sec Function Span Calibration Used key LCD screen Description ENTER key ...

Страница 25: ...er the calibration is completed Open the top cover Cover CAL switch in the left top of cover with sealing plate and screw 2 sealing bolt Connect the sealing wire as follows and compress the sealing lead OPTIONAL DRAWING 60 61 3 5 2 5 4 5 50 50 89 94 WALL MOUNT FIXED BRACKET INDICATOR GUDE BRACKET FIXED BRACKET 26 ...

Страница 26: ... memory is lost due to a electrical shock Management Perform the required specification again in setting mode Err 06 Cause The printer isn t properly connected Management Check that the printer connector has no fault If the message is displayed in spite of no fault in printer and printer connector call to A S part of CAS CO LTD Err 09 Cause The current weight exceeds zero range Err 10 Cause The sp...

Страница 27: ...or span calibration is set below 10 of max capacity Management Set the span weight for span calibration more than 10 of max capacity in CAL 3 of calibration menu Err 23 Cause The span weight for span calibration exceeds 100 of max capacity Management Set the span weight for span calibration within allowable capacity range in CAL 3 of calibration menu Err 24 Cause The resolution is set too high in ...

Страница 28: ...cell connector is properly connected Errors in count mode Err 61 Cause The count unit weight and sample weight are set too high Management Set the count unit weight low or the sample quantity high Err 62 Cause The count unit weight and sample weight are set too low Management Set the count unit weight high or the count sample quantity low 29 ...