Carson SA-400-93 14V Скачать руководство пользователя страница 1

TB0325B 

Page 1 of 7 

10/18/03 

 

 

 

 

 

 

 

Carson

 

 

 

MANUFACTURING COMPANY, INC.

 

 

 

 

CARSON MANUFACTURING CO., INC. 

5451 NORTH RURAL STREET 

INDIANAPOLIS, IN  46220 

(888) 577 6877    

www.carsonsirens.com

 

 

TECHNICAL BULLETIN 

   

RADIO

RADIO

 

HORN

HORN

 

MAN

MAN

 

WAIL

WAIL

 

YELP

YELP

 

PHASER

PHASER

 

SIREN

SIREN

 

PA

PA

 

VOL

VOL

 

SA400

SA400

 

OFF

OFF

 

ON

ON

 

 

 

INSTALLATION AND 

OPERATING MANUAL 

 

SA-400-93  14V 
SA-400-93  28V 

SA-400-93  PG (Positive GND) 

 
 

 

Sound Hazard 

- Sound level from siren speaker (>120dBA @ 10 feet) may cause hearing damage.  

Do not operate siren without adequate hearing protection for you and anyone in immediate vicinity. 

 

(Ref. OSHA 1910.95 for occupational noise exposure guidelines) 

 

Содержание SA-400-93 14V

Страница 1: ...AN WAIL WAIL YELP YELP PHASER PHASER SIREN SIREN PA PA VOL VOL SA400 SA400 OFF OFF ON ON INSTALLATION AND OPERATING MANUAL SA 400 93 14V SA 400 93 28V SA 400 93 PG Positive GND Sound Hazard Sound level from siren speaker 120dBA 10 feet may cause hearing damage Do not operate siren without adequate hearing protection for you and anyone in immediate vicinity Ref OSHA 1910 95 for occupational noise e...

Страница 2: ...r 40 Watts RMS Output 1 spkr OPERATING TEMPERATURE 15 F to 140 F SIZE 6 1 8 Wide X 2 1 2 High X 5 3 8 Deep WEIGHT 4 pounds NIGHT VISIBILITY Backlit front control panel when power is on PROTECTION High Voltage Siren output stops with input voltage above highest rating Stops high output power from blowing speaker Reverse Polarity Fuse blows when power is wired backwards Shorted Output Fuse blows if ...

Страница 3: ...ore than 1 4 Wiring Use wiring capable of handling the current required Make sure all connections are tight Route wiring to prevent wear overheating and interference with air bag deployment Install and check all wiring before connection to vehicle battery Testing Test all siren functions after installation to assure proper operation Test vehicle operation to assure no damage to vehicle Keep These ...

Страница 4: ...ction Brown Both leads must be used Connect 1 lead to each terminal or lead of the speaker When used with 2 speakers connect each brown lead to both speaker terminals or leads parallel circuit Observe polarity phasing when connecting 2 speakers Optional Radio Input Connection Blue Connect 1 lead to each terminal of the radio speaker or output connector The input is isolated and polarity is not imp...

Страница 5: ...ngested areas Horn and PA Override available in this mode PHASER The siren produces a very fast warble tone This mode should be used at intersections or in highly congested areas Horn and PA Override available in this mode OVERRIDE FUNCTIONS PUBLIC ADDRESS PA OVERRIDE By pressing the microphone button any siren tone output is turned off allowing the operator to use the siren as a public address am...

Страница 6: ... loose Intermittent Aux Input connection Low Vehicle voltage Is the speaker bell or tip loose Is the Aux Input used and wired properly The input voltage must be greater than lowest rating Intermittent siren tone High Voltage Protection Connector loose Loose connection at power source Mic Button activation Circuit breaker in supply connection Is the vehicle voltage regulator working properly Is the...

Страница 7: ...P4227 Knob rotary function switch gold replace with CP4852 silver knob 8 CP4228 Knob PA volume control gold replace with CP4853 silver knob 9 CP3954 Label front panel for SA 400 93 gold 73 LAMP Lamp T 1 3 4 14V Mini Wedge Base JKL 73 used on SA 400 93 14 PG E85 LAMP Lamp T 1 1 2 28V Mini Wedge Base JKL E85 used on SA 400 93 28 CP3570 Microphone CP3633 Microphone clip with mounting screws 10 CP3952...