Installation Instructions
CONTENTS
Page
SAFETY CONSIDERATIONS
. . . . . . . . . . . . . . . . . . . . . .1
MODEL NUMBER NOMENCLATURE AND
DIMENSIONS
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Rated Indoor Airflow
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
INSTALLATION
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Jobsite Survey
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Step 1 — Plan for Unit Location
. . . . . . . . . . . . . . . . . . .7
• ROOF MOUNT
Step 2 — Plan for Sequence of Unit Installation
. . .7
• CURB-MOUNTED INSTALLATION
• PAD-MOUNTED INSTALLATION
• FRAME-MOUNTED INSTALLATION
Step 3 — Inspect Unit
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Step 4 — Provide Unit Support
. . . . . . . . . . . . . . . . . . .7
• ROOF CURB MOUNT
• SLAB MOUNT (HORIZONTAL UNITS ONLY)
• ALTERNATE UNIT SUPPORT (IN LIEU OF CURB
OR SLAB MOUNT)
Step 5 — Field Fabricate Ductwork
. . . . . . . . . . . . . . .9
Step 6 — Rig and Place Unit
. . . . . . . . . . . . . . . . . . . . . .9
• POSITIONING ON CURB
Step 7 — Convert to Horizontal and Connect
Ductwork
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
Step 8 — Install Outside Air Hood
. . . . . . . . . . . . . . .11
• ECONOMIZER AND TWO-POSITION DAMPER
HOOD PACKAGE REMOVAL AND SETUP
(FACTORY OPTION)
• ECONOMIZER AND TWO-POSITION HOOD
Step 9 — Units with Hinged Panels Only
. . . . . . . . .12
Step 10 — Install Flue Hood
. . . . . . . . . . . . . . . . . . . . .12
Step 11 — Install Gas Piping
. . . . . . . . . . . . . . . . . . . . .13
• FACTORY-OPTION THRU-BASE CONNECTIONS
(GAS CONNECTIONS)
Step 12 — Install External Condensate Trap
and Line
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
Step 13 — Make Electrical Connections
. . . . . . . . 16
• FIELD POWER SUPPLY
• UNITS WITH FACTORY-INSTALLED NON-FUSED
DISCONNECT
• UNITS WITHOUT FACTORY-INSTALLED
NON-FUSED DISCONNECT
• ALL UNITS
• CONVENIENCE OUTLETS
• FACTORY-OPTION THRU-BASE CONNECTIONS
(ELECTRICAL CONNECTIONS)
• UNITS WITHOUT THRU-BASE CONNECTIONS
(ELECTRICAL CONNECTIONS)
• FIELD CONTROL WIRING
• THERMOSTAT
• HEAT ANTICIPATOR SETTINGS
• HUMIDI-MIZER
®
CONTROL CONNECTIONS
• TYPICAL UNIT WIRING DIAGRAMS
Integrated Gas Controller
. . . . . . . . . . . . . . . . . . . . . . .25
EconoMi$er
®
X (Factory Option)
. . . . . . . . . . . . . . . . .27
Page
RTU Open Controller (Factory Option)
. . . . . . . . . . . 41
SystemVu™ Controller (Factory Option)
. . . . . . . . 41
Controller Options
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
• LOW AMBIENT
Smoke Detectors
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Step 14 — Adjust Factory-Installed Options
. . . . . 42
Step 15 — Install Accessories
. . . . . . . . . . . . . . . . . . . 42
Step 16 — Fan Speed Set Up
. . . . . . . . . . . . . . . . . . . . 43
START-UP CHECKLIST
. . . . . . . . . . . . . . . . . . . . . . . .CL-1
SAFETY CONSIDERATIONS
Improper installation, adjustment, alteration, service,
maintenance, or use can cause explosion, fire, electrical
shock or other conditions which may cause personal injury or
property damage. Consult a qualified installer, service agen-
cy, or your distributor or branch for information or assistance.
The qualified installer or agency must use factory-authorized
kits or accessories when modifying this product. Refer to the
individual instructions packaged with the kits or accessories
when installing.
Follow all safety codes. Wear safety glasses and work
gloves. Use quenching cloths for brazing operations and have
a fire extinguisher available. Read these instructions thor-
oughly and follow all warnings or cautions attached to the
unit. Consult local building codes and appropriate national
electrical codes (in USA, ANSI/NFPA70, National Electrical
Code (NEC); in Canada, CSA C22.1) for special require-
ments.
It is important to recognize safety information. This is the
safety-alert symbol
. When you see this symbol on the
unit and in instructions or manuals, be alert to the potential
for personal injury.
Understand the signal words DANGER, WARNING,
CAUTION, and NOTE. These words are used with the safety-
alert symbol. DANGER identifies the most serious hazards
which will result in severe personal injury or death. WARNING
signifies hazards which could result in personal injury or death.
CAUTION is used to identify unsafe practices, which may result
in minor personal injury or product and property damage. NOTE
is used to highlight suggestions which will result in enhanced in-
stallation, reliability, or operation.
WARNING
Electrical shock can cause personal injury and death. Shut
off all power to this equipment during installation and ser-
vice. There may be more than one disconnect switch. Tag
all disconnect locations to alert others not to restore power
until work is completed.
WeatherMaker
®
48FC04-07 Single Package Rooftop
Gas Heating/Electric Cooling Unit
with Puron
®
(R-410A) Refrigerant
Содержание WeatherMaker 48FC04-07
Страница 4: ...4 Fig 2 Unit Dimensional Drawing 1018 ...
Страница 5: ...5 Fig 2 Unit Dimensional Drawing cont 1018 ...
Страница 6: ...6 Fig 2 Unit Dimensional Drawing cont 1018 ...
Страница 22: ...22 Fig 40 Typical Control Wiring Diagram Electro Mechanical with W7212 48FC 04 06 208 230 3 60 Unit Shown ...
Страница 23: ...23 Fig 41 Typical Electro Mechanical with W7220 Control Wiring Diagram 48FC 07 208 230 3 60 Unit Shown ...
Страница 24: ...24 T Fig 42 Typical 48FC 04 07 Power Wiring Diagram 208 230V Unit Shown ...
Страница 26: ...26 Fig 45 Typical IGC Control Wiring Diagram UNIT CONTROL BOARD ...