![Carrier WEATHERMAKER 48A4 Скачать руководство пользователя страница 1](http://html.mh-extra.com/html/carrier/weathermaker-48a4/weathermaker-48a4_wiring-diagrams_2560306001.webp)
Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.
Catalog No. 04-56480002-01
Printed in U.S.A.
Form 48/50A-3W
Pg 1 508 4-08
Replaces: New
Wiring Diagrams
INDEX
ACCESSORIES
NOTE: Accessory wiring is shown on the unit wiring diagrams. Refer
to the appropriate drawing for accessory wiring.
TYPE
UNIT
NUMBER
FIG. NO.
Component Arrangement
48/50A2,A3,A4,A5020-035
48EJ502489
1
48/50A2,A3,A4,A5040-060
48EJ503652
2
Power Schematic
48/50A2,A3,A4,A5020-050
50EJ500470
3
48/50A2,A3,A4,A5060 RTPF
50EJ500469
4
48/50A2,A3,A4,A5060 MCHX
50EJ500420
5
Main Control Box Circuit
48/50A2,A3,A4,A5020-060
50EJ500440
6
Auxiliary Control Box Wiring
48/50A2,A3,A4,A5020-060
48EJ503076
7
Controls Expansion
Board Wiring
48/50A2,A3,A4,A5020-060
48EJ503086
8
Gas Heat Control Circuit
(2-Stage Heat)
48A2,A3,A4,A5020-050
48EJ503079
9
48A2,A3,A4,A5060
48EJ503679
10
Gas Heat Control Circuit
(Staged Gas Heat)
48A2,A3,A4,A5020-050
48EJ502488
11
48A2,A3,A4,A5060
48EJ503680
12
Electric Heat Control Circuit
50A2,A3,A4,A5020-050
48EJ503080
13
50A2,A3,A4,A5060
48EJ503655
14
ACCESSORY
UNIT
FIG. NO.
Motormaster® V Low Ambient Controller
48/50A2,A3,A4,A5020-035
15
48/50A2,A3,A4,A5040,050 AND 060 RTPF Units
16
48/50A2,A3,A4,A5060 MCHX Units
17
Space Sensor Temperature Averaging
48/50A2,A3,A4,A5020-060
18
Thermostat
48/50A2,A3,A4,A5020-060
6
Remote Economizer Position Override
Remote Economizer Minimum Position Set Point
Remote 4 to 20 mA Economizer Position
Space IAQ Sensor
Outdoor Enthalpy Changeover Sensor
48/50A2,A3,A4,A5020-060
7
Differential Enthalpy Changeover Sensor
Outdoor Air Quality Sensor
48/50A2,A3,A4,A5020-060
8
Remote Supply Air Set Point
Demand Limit Controller
Fan Status Switch
Demand Limit
Fire Pressurization
Fire Evacuation
Fire Smoke Purge
IAQ Override Switch
WEATHERMAKER
®
48/50A2,A3,A4,A5020-060
Single Package Rooftop
Gas Heating/Electric Cooling and Electric Cooling Units
with
COMFORT
LINK™ Controls
Содержание WEATHERMAKER 48A4
Страница 8: ...8 Fig 1 Component Arrangement 48 50A2 A3 A4 A5020 035 Units a48 8308 ...
Страница 10: ...10 Fig 3 Power Schematic 48 50A2 A3 A4 A5020 050 Units a48 8385 ...
Страница 11: ...11 Fig 4 Power Schematic 48 50A2 A3 A4 A5060 RTPF Units a48 8386 ...
Страница 12: ...12 Fig 5 Power Schematic 48 50A2 A3 A4 A5060 MCHX Units a48 8387 ...
Страница 13: ...13 TO NEXT PAGE Fig 6 Main Control Box Circuit 48 50A2 A3 A4 A5020 060 Units a48 8388 ...
Страница 14: ...14 TO PREVIOUS PAGE a48 8389 Fig 6 Main Control Box Circuit 48 50A2 A3 A4 A5020 060 Units cont ...
Страница 16: ...16 Fig 8 Controls Expansion Board Wiring 48 50A2 A3 A4 A5020 060 Units a48 8261 ...
Страница 17: ...17 Fig 9 Gas Heat Control Circuit 2 Stage Heat 48A2 A3 A4 A5020 050 Units a48 8310 ...
Страница 18: ...18 Fig 10 Gas Heat Control Circuit 2 Stage Heat 48A2 A3 A4 A5060 Units a48 8311 ...
Страница 19: ...19 Fig 11 Gas Heat Control Circuit Staged Gas Heat 48A2 A3 A4 A5020 050 Units a48 8313 ...
Страница 20: ...20 Fig 12 Gas Heat Control Circuit Staged Gas Heat 48A2 A3 A4 A5060 Units a48 8315 ...
Страница 21: ...21 Fig 13 Electric Heat Control Circuit 50A2 A3 A4 A5020 050 Units a48 8266 ...
Страница 22: ...22 Fig 14 Electric Heat Control Circuit 50A2 A3 A4 A5060 Units a48 8267 ...
Страница 26: ......
Страница 27: ......