1.10 ENGINE DATA
(Continued)
i. Intake Heater
Amperage
−
42 amps at 12 VDC
Resistance (cold)
−
Approx. 0.3 ohms
j. Horsepower
27 HP @ 1800 RPM at 3000 feet above sea level.
32 HP @ 1800 RPM at sea level.
k. Cooling System
Capacity
6 U.S. quarts (5.68 liters)
−
includes 1 quart (0.95 liter) in
coolant recovery bottle. (Refer to section 4.4.5)
Anti
−
Freeze:
Conventional
The cooling system may be factory charged with a 50/50 mix
of ethylene glycol and water. This mixture provides protection
to
−
34
°
F (
−
37
°
C). For replacement, use a low silicate anti
−
freeze meeting GM specifications GM 6038M or equal. Again,
a 50/50 mix is recommended.
Anti
−
Freeze:
Extended Life
The cooling system may be factory charged with a 50/50 mix
of extended life coolant (ELC) and deionized water. This mix-
ture provides protection to
−
34
°
F (
−
37
°
C). For replacement,
with extended life coolant (ELC) meeting GM specification
GM6277M and deionized water. Again, a 50/50 mix is recom-
mended. Extended life coolant is red or orange in color.
DO NOT
mix with conventional coolant.
Water Temperature
Safety Switch
Setting
Opens
230 +/
−
5
°
F (110 +/
−
3
°
C)
Resets
200
°
F (93
°
C)
−
minimum
Thermostat
Starts to open
177 to 182
°
F (80 to 84
°
C)
Fully open
203
°
F (95
°
C)
Low Coolant
Sensor
Opens
Closes
Loss of 32 ounces of coolant or more
Refilling of radiator to proper level
l. Lubrication System
Oil Pressure
35 to 60 psig (3.3 to 5.2 kg/cm
@
)
m. Electrical
Generator
460 VAC (+/
−
10%) @ 60 hz