background image

Содержание TP-WEM01

Страница 1: ...Installation Guide A14577 ...

Страница 2: ...we re here to help Visit www carrier com corsupport for how to videos answers to frequently asked questions and advanced installation instructions Technical support is also available by phone or emaiI weekdays from 8 a m 5 p m EST o 1 800 CARRIER or 1 800 227 7437 c_ contact carrier carrier utc com The C6r thermostat is also supported by the world s greatest network of professional contractors Fin...

Страница 3: ...o Dual Fuel Systems Gas Furnace with a Heat Pump o Geothermal Systems o Accessories Whole Home Humidifier Dehumidifier or Ventilator o 802 11 b gin Home Wireless Router Before beginning installation check the compatibility of your home comfort system at www carrier com wirecheck Professional installation is recommended for o Systems Without a Common C Wire see page 5 o Variable Speed Systems o Fin...

Страница 4: ...X A The C6r TM Thermostat and backptate B Mounting screws and drywall plugs C Installation guide quick start guide and wire labels D Large Backptate optional Wire Labels Installation Guide Quick Start Guide B f D k 6_ A150042 ...

Страница 5: ...INSTALLATION A Pencil B Phillips screwdriver C Small flathead screwdriver D Drill with a 3 16 drill bit E Password for your home s wireless network F Internet connected device such as a smartphone tablet or computer A150044 ...

Страница 6: ...ttached by screws A If you do not have a wire connected to C visit www carrier com corsupport for Advanced Installation and Configuration Instructions B If you have wires connected to Rh Rc and C You ll use two breakers or switches to disconnect power in Step 2 A RcRHG YWC RcRHG YW C A150045 ...

Страница 7: ...s either at your circuit breaker box or a switch at your indoor furnace or fan coil Most systems have one switch but systems with Rh Rc and C wires noted in Step 1 will have two switches Make sure your system is without power by using your old thermostat to adjust the temperature Your system should not turn on At50046 ...

Страница 8: ...nnected wires Disconnect each wire Most thermostats wires are connected using screws simply loosen each screw with a screwdriver Remove your old thermostat base by unscrewing it from the wail Be careful not to let any wire labels fall off or wires fall back into the wall Discard any jumper wires or brackets between Rh Rc or R Rc Rh G Y w C U A150047 ...

Страница 9: ...the back plate Center the wires in the back plate Mark the mounting holes on the wall with a pencil Drill mounting holes on the pencil marks with a 3 16 drill bit Insert the plastic drywall anchors into the wall Use the screws provided to secure the back plate to the wall A150048 ...

Страница 10: ...se the large backptate instead Remove the terminal blocks from the small backptate by squeezing the tab on the front left side while gently pushing the back toward you Insert the terminal blocks into the large backplate using the tabs on the right as a guide It will snap into place when correctly inserted _J then A150049 ...

Страница 11: ...connector block Insert only one wire in each connector When installed correctly the release lever of the terminal block will lower to indicate a complete connection Gently tug on the wire to ensure it s fully connected When all the wires are connected gently push any excess wire back into the wall A150050 ...

Страница 12: ...r it snap into place r _ A150051 Now you can turn the power back on to your heating and cooling system Return to your circuit breaker or on off switch and restore the power to your system The C6r thermostat will automatically power on In about one minute its guided software setup will be ready to help you complete your installation ...

Страница 13: ... walk you through 1 Equipment configuration 2 Customizing your preferences 3 Connecting to your home s wireless network 4 Registering your thermostat online The information icon at bottom of the screen will provide helpful explanations and tips for each step in the process At50052 ...

Страница 14: ...cted the Rh and Rc and C wires select two o Otherwise select one b The C6r thermostat automatically detects the wires you ve connected and will ask a few questions to configure your system based on these connections c If you have a connected accessory such as a whole home humidifier dehumidifier or ventilation device you ll also configure it here ...

Страница 15: ...ustomize your CSr thermostat a Name your thermostat by selecting a name from the list or by entering your own custom name b Tell the C6r thermostat whether you prefer the temperature to display in Fahrenheit or Celsius c Then adjust your home comfort temperature for the heating and cooling seasons ...

Страница 16: ... provides you the most features and energy savings when it s connected to your home s wireless network and your personal web portal a The C6r thermostat automatically detects nearby wireless networks b Select your network from the list and enter your network password ...

Страница 17: ...mostat a On your Android or Apple smart device download the Carrier CSr thermostat app from the app store b Open the app and touch register on the Iogin screen c Enter the four digit code generated from your thermostat and follow the onscreen prompts to complete your registration d Return to your thermostat and accept your registration At50053 ...

Страница 18: ...the power back on to the equipment either at the switch at the indoor equipment or the electri cal panel where you originally turned off the equipment 3 If your device still doesn t power on check the AC voltage between Rc and C or Rh and C using a multi meter to ensure it is 24V AC 4 If your device still does not power on please contact c_ Technical support at 1 800 CARRIER or contact contact car...

Страница 19: ... installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures o Reorient or relocate the receiving antenna o Increase the separation between the equipment and receiver o Connect the equipment into an outlet...

Страница 20: ...ion of the device Le present appareil est conforme aux CNR d lndustrie Canada applicable aux appareils radio exempts de licence L exploitation est autorisee aux deux conditions suivantes 1 rappareil ne doit pas produire de brouillage et 2 rutilisateur de rappareil doit accepter tout brouillage radioelectrique subi m6me si le brouillage est susceptible d en compromettre le fonction nement This Clas...

Страница 21: ... maintenance as follows All warranty periods begin on the date of purchase If a part fails due to defect during the applicable warranty period Company will provide a new or remanufactured part at Company s option to replace the failed defective part at no charge for the part Alternatively and at its option the Company will provide a credit in the amount of the then factory selling price for a new ...

Страница 22: ...ty benefits conditioned on registration See Warranty Conditions below OTHER APPLICATIONS The warranty period is one 1 year on all such applications The warranty is to the original owner only and is not available for subsequent owners LEGAL REMEDIES The owner must notify the Company in writing by certified or registered letter to Carrier Corporation Warranty Claims P O Box 4808 Syracuse New York 13...

Страница 23: ...rom the builder 3 If the date of original purchase cannot be verified then the warranty peri od begins ninety 90 days from the date of product manufacture as indi cated by the model and serial number Proof of purchase may be re quired at time of service 4 The limited parts warranty period as shown in the table under subsequent owners does not require registration 5 The warranty applies only to pro...

Страница 24: ...TY DOES NOT COVER 1 Labor or other costs incurred for diagnosing repairing removing in stalling shipping servicing or handling of either defective parts or re placement parts or new units 2 Any product not installed pursuant to applicable regional efficiency standards issued by the Department of Energy 3 Normal maintenance as outlined in the installation and servicing instruc tions or Owner s Manu...

Страница 25: ... fuel costs from any reason whatsoever including additional or unusual use of supplemental electric heat 10 Any cost to replace refill or dispose of refrigerant including the cost of refrigerant 11 ANY SPECIAL INDIRECT OR CONSEQUENTIAL PROPERTY OR COMMERCIAL DAMAGE OF ANY NATURE WHATSOEVER Some states or provinces do not allow the exclusion of incidental or con sequential damages so the above limi...

Страница 26: ...ight 2015 Carrier Corp 7310 W Morris St Indianapolis IN 46231 Edition Date 02 15 Cataloq No TP WEM O4Sl Manufacturer reserves the right to change at any time specifications and designs without notice and without obligations Replaces TP WEM O3SI ...

Отзывы: