background image

TB---NAC

TB---NHP

Base Series

Non---Programmable Thermostat

Installation Instructions

A07108

Base Non---Programmable Thermostat

NOTE

: Read the entire instruction manual before starting the

installation.

TABLE OF CONTENTS

PAGE

SAFETY CONSIDERATIONS

1

. . . . . . . . . . . . . . . . . . . . . . . . .

INTRODUCTION

1

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

INSTALLATION CONSIDERATIONS

1

. . . . . . . . . . . . . . . . . . .

INSTALLATION

1

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Step 1 — Thermostat Location

1

. . . . . . . . . . . . . . . . . . . . . . . .

Step 2— Install Thermostat

2

. . . . . . . . . . . . . . . . . . . . . . . . . . .

Step 3 — Set Thermostat Configuration

2

. . . . . . . . . . . . . . . . .

Step 4 — Thermostat Operation

3

. . . . . . . . . . . . . . . . . . . . . . . .

Step 5 — Check Thermostat Operation

3

. . . . . . . . . . . . . . . . . .

WIRING DIAGRAMS

4

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

SAFETY CONSIDERATIONS

Read and follow manufacturer instructions carefully. Follow all

local electrical codes during installation. All wiring must conform

to local and national electrical codes. Improper wiring or
installation may damage thermostat.

Recognize safety information. This is the safety--alert symbol

.

When you see this symbol on the equipment and in the instruction
manual, be alert to the potential for personal injury. Understand the

signal words

DANGER

,

WARNING

, and

CAUTION

.

These words are used with the safety--alert symbol.

DANGER

identifies the most serious hazards which will result in severe

personal injury or death.

WARNING

signifies a hazard which

could result in personal injury or death.

CAUTION

is used to

identify unsafe practices which may result in minor personal injury

or product and property damage.

NOTE

is used to highlight

suggestions which will result in enhanced installation, reliability, or

operation.

INTRODUCTION

The Base Series thermostat is an

electronic 24VAC,

non--programmable, manual changeover wall mount thermostat.

This thermostat uses a single setpoint to maintain and control room
temperature in both the heating and air conditioning modes. The

thermostat is designed to ma/-- 2

_

F accuracy. No batteries

are required; temperature, fan, mode, and installer configuration

settings are preserved with power off.

INSTALLATION CONSIDERATIONS

Air Conditioner Model

TB--NAC, Base Series Model air conditioner thermostat, may be
wired with or without connecting a common wire between the

indoor equipment and the thermostat. However, it is recommended

to use a common wire whenever possible. Without a common wire
this thermostat becomes “power stealing.” This means it will need

to steal a small amount of power from the equipment to which it is
connected.

NOTE

: Not all HVAC equipment is compatible with power

stealing type thermostats. All Carrier equipment is directly
compatible with this thermostat except the Thermostat Conversion
Kit, Part #TSTATXXCNV10. For all non--Carrier equipment,
consult the system equipment Installation Instructions before
applying this thermostat in a power stealing manner.

Heat Pump Model

TB--NHP, Base Series Model heat pump thermostat, is compatible

with all Carrier heat pump systems. It is NOT power stealing and
MUST have both the R and C terminals connected to operate

properly. This thermostat uses a green LED to indicate auxiliary
heat and emergency heat operation.

INSTALLATION

Step 1 — Thermostat Location

Thermostat should be mounted:

S

Approximately 5 ft (1.5m) from floor.

S

Close to or in a frequently used room, preferably on an
inside partitioning wall.

S

On a section of wall without pipes or duct work.

Thermostat should NOT be mounted:

S

Close to a window, on an outside wall, or next to a door
leading to the outside.

S

Exposed to direct light and heat from the sun, a lamp,
fireplace, or other heat--radiating object which may cause

a false reading.

Содержание TB-NAC

Страница 1: ...rol room temperature in both the heating and air conditioning modes The thermostat is designed to maintain 2_F accuracy No batteries are required temperature fan mode and installer configuration settings are preserved with power off INSTALLATION CONSIDERATIONS Air Conditioner Model TB NAC Base Series Model air conditioner thermostat may be wired with or without connecting a common wire between the...

Страница 2: ...ption 10 O reversing valve On with Heat or Cool present on Heat Pump model only Option 13 Room temperature offset adjustment Note that not all configuration option numbers are used in this product To Enter The Configuration Mode Press and hold FAN button for approximately 10 sec until room temperature disappears and the display reads 01 You are now in configuration mode NOTE If FAN button is press...

Страница 3: ...e the equipment has turned on it will remain on for a minimum of 3 minutes regardless of demand However the equipment can turn off in less than 3 minutes if a change in setpoint or a change in mode occurs Staging Timer If the thermostat is a heat pump model it has 2 stage heat capability With HP operation there is a 15 minute delay between the first and second stages of heat The Y output will ener...

Страница 4: ...Typical Installation Copyright 2007 Carrier Corp S 7310 W Morris St S Indianapolis IN 46231 Printed in U S A Edition Date 02 07 Manufacturer reserves the right to change at any time specifications and designs without notice and without obligations Catalog No TB NAC 1SI Replaces NEW TB NAC TB NHP ...

Страница 5: ...dicated by the FAN ON icon and auto fan operation 3 To Read the Room Temperature The large display reads room temperature until a button is pressed 4 To Adjust the Setpoint In normal operation the large display shows room temperature At the first press of the UP or DOWN button the large display shows the current setpoint and the SET TEMP icon is turned on Further presses of the UP or DOWN button a...

Страница 6: ...ES ALL IMPLIED WARRANTIES INCLUDING IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY LIMITED IN DURATION TO THE PERIOD FOR WHICH THE LIMITED WARRANTY IS GIVEN AND APPLIES SOME STATES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS SO THE ABOVE MAY NOT APPLY TO YOU THE EXPRESSED WARRANTIES MADE IN THIS WARRANTY ARE EXCLUSIVE AND MAY NOT BE ALTERED...

Отзывы: