manualshive.com logo in svg
background image

Model C300 NP

Non-Pressurized

Slush Freezer

Operating Instructions

055072NP

9/22/06

Содержание Taylor C300 NP

Страница 1: ...Model C300 NP Non Pressurized Slush Freezer Operating Instructions 055072NP 9 22 06...

Страница 2: ...l Number Serial Number Electrical Specs Voltage Cycle Phase Maximum Fuse Size A Minimum Wire Ampacity A E September 2006 Taylor All rights reserved 055072NP The word Taylor and the Crown design are re...

Страница 3: ...ssembly 7 Accessories 8 Section 5 Important To the Operator 9 Symbol Definitions 9 Control Switch 10 Liquid Crystal Display 10 Operational Mode Display 10 Operator Menu Display 10 Syrup Out Indicator...

Страница 4: ...cement Schedule 33 Section 10 Parts List 34 Wiring Diagrams 43 Note Continuing research results in steady improvements therefore information in this manual is subject to change without notice E Septem...

Страница 5: ...gh the outlet fitting located at the top of the condenser to an open trap drain IMPORTANT Water pressures are pre set at the factory Do not adjust the water pressure Improper water adjustments may cau...

Страница 6: ...ially free from hazard In all other areas of the world equipment should be installed in accordance with the existing local codes Please contact your local authorities Stationary appliances which are n...

Страница 7: ...contact the municipal facility and or local distributor Compressor Warranty Disclaimer The refrigeration compressor s on this machine are warranted for the term indicated on the warranty card accompa...

Страница 8: ...than specified on the freezer data label Failure to follow these instructions may result in electrocution Contact your local authorized Taylor Distributor for service DO NOT use a water jet to clean...

Страница 9: ...the ceiling This is required to allow for adequate air flow through the condenser s Failure to follow this instruction may cause poor freezer performance and damage to the machine This freezer is des...

Страница 10: ...DESCRIPTION PART NO 1 PANEL SIDE LEFT 054676 2 PANEL REAR 054672 3 PANEL SIDE RIGHT 054671 4 DISPLAY LIGHTED 054683 27 5 PANEL FRONT UPPER 054669 6 PANEL FRONT SHELL 054668 ITEM DESCRIPTION PART NO 7...

Страница 11: ...RAW SLUSH SLFCL 047734 SP 1e O RING 1 OD X 139W 032504 1f HANDLE A DRAW SLUSH BLK X47384 1g PLUG PRIME STNLS 050405 1h O RING 563 OD X 070W 013 043758 1i DOOR A PARTIAL SLUSH X57324 SER 1j BUSTER ICE...

Страница 12: ...260 048260 R Figure 5 ITEM DESCRIPTION PART NO 1 PAIL MIX 10 QT 013163 2a BRUSH MIX PUMP BODY 3 X7 023316 2b BRUSH DOUBLE ENDED 013072 2c BRUSH REAR BRG 1 DX2 L 013071 ITEM DESCRIPTION PART NO 2d BRUS...

Страница 13: ...LIGHT LEFT SIDE 2 CONTROL SWITCH 3 KEYPAD LEFT SIDE 4 LIQUID CRYSTAL DISPLAY 5 KEYPAD RIGHT SIDE 6 PRODUCT LIGHT RIGHT SIDE Symbol Definitions To better communicate in the International arena symbols...

Страница 14: ...passes then the next screen appears OFF MODE OFF OK SYRUP OK CO2 OK WATER OK Note Syrup CO2 and water are satisfied Pressing the AUTO keys on both sides of the unit will display this screen AUTO MODE...

Страница 15: ...inder temperature is above 120 F 49 C BRL Not Cooling Freezing cylinder is not cooling after 5 minutes No Fault Found No fault conditions are apparent The following are explanations of the possible fa...

Страница 16: ...DESCRIPTION L H2O PRESSURE LOW R H2O PRESSURE LOW CLR SEL 9 BRL NOT COOLING A freezing cylinder check has been established for the AUTO mode of operation If a freezing cylinder enters the AUTO mode th...

Страница 17: ...screen allows the operator to manually defrost the left side of the unit Place the cursor under YES press the MENU SEL key and the command will be executed MANUAL DEFROST LEFT SIDE YES NO SEL Repeat...

Страница 18: ...UN 10 00 SEL Press the MENU SEL key to return to the OPERATOR MENU Screen F is CURRENT CONDITIONS This screen displays the current viscosity product temperature and pressure for each freezing cylinder...

Страница 19: ...ce information Press the MENU SEL key to return to the OPERATOR MENU OPERATOR MENU A B C D E F G H I SERVICE MENU SEL Syrup Out Indicator AUTO MODE AUTO OUT SYRUP OK CO2 OK WATER OK If the word OUT ap...

Страница 20: ...dio Alarm Silencer The audio alarm will be disabled if the ALARM SILENCE key is pressed If a new fault or fault condition occurs or the system mode changes the audio alarm will be re enabled automatic...

Страница 21: ...d information to get to this starting point in our instructions turn to page 27 Disassembly and start there Assembly MAKE SURE THE CONTROL SWITCH IS IN THE OFF POSITION Failure to do so may result in...

Страница 22: ...ightly to be certain that the beater is properly seated When in position the beater will not protrude beyond the front of the freezing cylinder 10616 Figure 10 Step 5 Install the white plastic guide b...

Страница 23: ...e ice buster through the door spout and into the slot located just above the lower o ring 11262 Figure 15 Step 11 With the ice buster in place rotate the draw valve to allow installation of the draw h...

Страница 24: ...ing cylinder and push the door into place Install the four handscrews onto the studs and tighten them equally in a crisscross pattern to insure that the door is snug DO NOT over tighten the handscrews...

Страница 25: ...zing solution example Kay 5R USE WARM WATER AND FOLLOW THE MANUFACTURER S SPECIFICATIONS Important Make sure the sanitizer is completely dissolved Step 3 Using an empty bag of syrup cut the syrup line...

Страница 26: ...O SEL Step 8 Open the prime plugs Place an empty pail under the door spouts When sanitizing solution fills the freezing cylinders approximately 2 3 full close the prime plugs Step 9 Continue filling t...

Страница 27: ...er position Figure 28 Step 5 Press the PRIME key Figure 29 Step 6 Slowly move the syrup sampling valve to the fully open position by turning the handle down toward the sampling line Allow the liquid t...

Страница 28: ...re 32 Step 9 To adjust the brix turn the adjustment screw located behind the drip tray shelf Clockwise adjustments increase the amount of syrup to water and counterclockwise adjustments decrease the a...

Страница 29: ...UTO mode press the AUTO key on both sides When the unit cycles off the product will be at serving viscosity Figure 35 Step 16 Close the lighted display when complete Replace the panels and the hood an...

Страница 30: ...Move the cursor under the word YES Pressing the MENU SEL key at this time will start the beater motor and deliver water and CO2 to the left cylinder RINSE LEFT SIDE YES NO SEL Step 3 Allow the rinse...

Страница 31: ...l approximately 2 3 full Close each prime plug Step 5 Continue filling the freezing cylinders with sanitizing solution until the solution purges out of each vent and begins draining into the front dri...

Страница 32: ...freezer doors S draw valves from freezer doors S o rings from draw valves S prime plugs from freezer doors S o rings from prime plugs S gaskets and front bearings from freezer doors S baffle assembly...

Страница 33: ...ree of lubricant and product deposits j 5 Properly prepare the cleaning and sanitizing solutions Read and follow the label directions carefully Too strong of a solution may damage the parts and too we...

Страница 34: ...r can perform this service for you Wrap detachable parts of the freezer such as the beater the scraper blades the drive shaft and the freezer door Place these parts in a protected dry place Rubber tri...

Страница 35: ...is being dispensed a Product frozen up in freezing cylinder a See problem No 1 4 Freezer will not operate in the BEATER or AUTO mode a Unit is unplugged a Check the plug at wall receptacle b Blown fus...

Страница 36: ...ncorrectly installed a Replace or install correctly on drive shaft 17 b Worn rear shell bearing b Contact a service technician to replace rear shell bearing 9 Excessive mix leakage from door spout a I...

Страница 37: ...haft Seal X Drive Shaft O Ring X Freezer Door Gasket X Draw Valve O Ring X Front Bearing X Prime Plug O Ring X Black Bristle Brush 1 x 2 Inspect Replace if Necessary Minimum Double Ended Brush Inspect...

Страница 38: ...QT 1 PIN SUPPORT X46233 2 103 BLADE SCRAPER PLASTIC 9 13 1 046237 4 000 CLIP SCRAPER BLADE 8 75 INCH 046238 4 103 BELT 1 2IN PITCH 240H100 033145 1 000 BEARING UNIT 208 230 60HZ 1PH BELT POLY V 540J10...

Страница 39: ...197 1 000 CONDENSER AC 16X16 3 ROW 14FPI 054660 1 103 COUPLING A TORQUE FCB HEX X48939 2 103 COUPLING TORQUE DRIVE 046866 2 103 COUPLING TORQUE LOAD HEX 039397 2 103 PIN COUPLING TORQUE 039453 3 103 S...

Страница 40: ...IT SIDE FASTENER DOOR STRIKE 030788 1 000 POP DISPLAY FILTER AIR 15 88LX15 88HX 70W 052779 5 1 000 COVER HOLE FILTER C300 054673 2 NNN FILTER CORCOM 6EH1 040140 001 1 103 FILTER H20 5 MICRON INLINE W...

Страница 41: ...49 1 000 LABEL SWITCH CONTROL 053145 1 000 LABEL WARN COVER 051433 4 000 LABEL WARN NO DRAW 042279 2 000 LED A PRODUCT NOT READY 059711 1 103 LENS YEL LED SNAP IN 1 4 HOLE 051751 2 103 LINE A WATER C3...

Страница 42: ...60HZ 3PH BASE MOTOR C300 FRONT 065681 1 103 MOTOR 1 3 HP 870 RPM 054631 27 1 212 S N K7070000 PRIOR USE X65952 27 KIT TO UPGRADE 196 208 230V 60HZ 1PH 208 230 60HZ 3PH CAPACITOR START 108 130UF 250V...

Страница 43: ...039 1 103 PUMP GAS OPERATED WATER BOOST 064363 1 103 K6050000 UP REPLACES 055526 REGULATOR A CO2 C300 NP X56841 1 103 REGULATOR CO2 TANK DOUBLE 051840 1 103 REGULATOR WATER 30 PSI FIXED 064388 1 103 L...

Страница 44: ...1 103 O RING 3 875 OD X 139W 055388 1 000 SCREW 10X1 2 UNSLTD HWH 055389 3 000 CLIP RETAINER TUBE MIX C300 062289 1 103 CAP TANK MIX TOP NP 056808 1 103 O RING 3 875 OD X 139W 055388 1 000 SCREW 10X1...

Страница 45: ...EW 10X3 8 SLOTTED HEX WSH 015582 1 000 VALVE SAMPLING 3 WAY ORING F 056571 2 103 WATER COOLED BLOWER 100 CFM 012796 27 1 103 BRACKET CONDENSER C300 W 056357 1 NNN BRACKET CONDENSER C300 W 056358 1 NNN...

Страница 46: ...LIGHTED C300 P 0 P 054683 40 1 103 HARNESS WIRE C300 PWR COMP 056334 58 1 103 HARNESS WIRE C300 HI VOLT NP 056827 40 1 103 MOTOR 1 4 HP W OUT BASE 014477 40B 1 212 S N J7084784 UP BASE MOTOR C300 FRO...

Страница 47: ...C300NP 056828 27 9 06...

Страница 48: ...C300NP 056828 27 Inset 9 06...

Страница 49: ...C300NP 056828 33 9 06...

Страница 50: ...C300NP 056828 58 9 06...

Отзывы: