14
Table 6: Technical Specifications
112 Series, multi-position models
Firing rate (USGPH)*
0,68
0,80
0,68
0,80
Input (BTU/h)*
95 200
112 000
95 200
112 000
Maximum Heating capacity, (BTU/h)*
81 000
94 000
81 000
94 000
Heating temperature rise (Degr. F)*
Flue draft with chimney (inch of w.c.)
Overfire pressure with chimney (inch of w.c.)
Flue pressure with direct vent (inch of w.c. - no wind)
Overfire pressure with direct vent (inch of w.c. - no wind)
BECKETT BURNER; MODEL AFG (Chimney)
Burner tube insertion length (inches)
Head type
Nozzle (Delavan)**
0.60 - 60W
0.65 - 60B
0.60 - 60W
0.65 - 60B
Pump pressure (PSIG)*
140
150
140
150
Head/Air setting
10/0
10/0 (Note 1)
10/0
10/0 (Note 1)
AFUE % (From CSA B212 standard and Canadian regulation)***
86,3%
85.6%
86,3% ‡
85.6% ‡
AFUE % (From ASHRAE 103 standard and US regulation)***
85.3%
85.4%
85.3% ‡
85.4% ‡
BECKETT BURNER; MODEL NX (Chimney or DV)
Burner tube insertion length (inches)
Head type
Nozzle (Delavan)**
0.60 - 60A
0.70 - 60A
0.60 - 60A
0.70 - 60A
Pump pressure (PSIG)*
130
130
130
130
Head/Air setting
3,5
2,5
3,5
2,5
AFUE % (From CSA B212 standard and Canadian regulation)***
87,1%
86,6%
87,1% ‡
86,6% ‡
AFUE % (From ASHRAE 103 standard and US regulation)***
85.8%
85.3%
85.8% ‡
85.3% ‡
RIELLO BURNER; MODEL 40-F3 (Chimney)
Burner tube insertion length (inches)
Nozzle (Delavan)**
0.60 - 70A
0.70 - 70A
0.60 - 70A
0.70 - 70A
Pump pressure (PSIG)*
130
130
130
130
Combustion air adjustment (turbulator/damper)
1 / 2.6
2 / 3.1
1 / 2.6
2 / 3.1
AFUE % (From CSA B212 standard and Canadian regulation)***
87,0%
86,8%
87,0% ‡
86,8% ‡
AFUE % (From ASHRAE 103 standard and US regulation)***
85.8%
85.4%
85.8% ‡
85.4% ‡
RIELLO BURNER; MODEL 40-BF5 (Direct vent DV)
Burner tube insertion length (inches)
Nozzle (Delavan)**
0.60 - 70A
0.70 - 70A
0.60 - 70A
0.70 - 70A
Pump pressure (PSIG)*
130
130
130
130
Combustion air adjustment (turbulator/damper)
0 / 2.75
0 / 3.25
0 / 2.75
0 / 3.25
AFUE % (From CSA B212 standard and Canadian regulation)***
86,7%
85.5%
86,7% ‡
85.5% ‡
AFUE % (From ASHRAE 103 standard and US regulation)***
85.5%
85.3%
85.5% ‡
85.3% ‡
Volts - Hertz - Phase
Rated current (Amps)
Minimum ampacity for wire sizing (Amps)
Max. fuse size (Amps)
Control transformer (VA)
External control power available Heating (VA)
Cooling (VA)
Heating blower speed at 0.25" W.C. SP
MED-LOW
MED-HIGH
Heating blower speed at 0.50" W.C. SP
MED-LOW
MED-HIGH
Motor (HP) / number of speeds
Blower size (diam. x width)
Overall dimensions (width x depth x height)
Supply air opening (width x depth)
Return air opening (width x depth)
Filter size
Shipping weight Lbs/Kg
Air conditioning, maximum output (tons) at 0.5" W.C. SP
Note 1 :
Without low firing baffle # 3708
* INPUT & OUTPUT ADJUSTMENT
- Pump pressure can be adjusted to maintain proper firing rate.
- Increase pump pressure if flue gases temperature are under 400°F
- Adjust the total flue gas temperature between 400°F and 575°F (330° and 505°F net approx.)
- Adjust flue gas temperature between 400˚ and 575˚F.
** Default Installed Nozzle in bold characters.
UNITS 1/2 HP 4-SPEED MOTOR
UNITS WITH 1/2 HP ECM MOTOR
RATING AND PERFORMANCE
55 - 75 Degr. F
60 - 72 Degr. F
-0.06 to -0.025
-0.06 to -0.025
-0.035 to +0.025
-0.035 to +0.025
+0.03 to +0.15
+0.03 to +0.15
+0.05 to +0.17
+0.05 to +0.17
AFG70MQSS
AFG70MQSS
1 3/4''
1 3/4''
2 - Slot L2 head
2 - Slot L2 head
NX56LQ
NX56LQ
1 3/4''
1 3/4''
6 - Slot LQ head
6 - Slot LQ head
F3 WITH AIR INLET DAMPER
F3 WITH AIR INLET DAMPER
2 3/4''
2 3/4''
BF5
BF5
2 3/4''
2 3/4''
ELECTRICAL SYSTEM
115 - 60 - 1
115 - 60 - 1
12,6
10,3
15,2
12,2
20
15
40
40
40
40
30
30
BLOWER DATA
See the ECM air flow table
1/2 HP / 4 speeds
1/2 HP / ECM
10'' x 10'' (tight housing)
10'' x 10'' (tight housing)
GENERAL INFORMATION
21 3/4'' x 25 3/4'' x 41 1/2''
21 3/4'' x 25 3/4'' x 41 1/2''
17 3/4'' x 18 3/4''
17 3/4'' x 18 3/4''
23'' x 19''
23'' x 19''
24'' x 20'' x 1"
24'' x 20'' x 1"
153 Lbs / 70 Kg
153 Lbs / 70 Kg
3,5
3,5
‡ =
Содержание OBM112 Series
Страница 17: ...17 Figure 9 Furnace Dimensions ...
Страница 18: ...18 Figure 10 Wiring Diagram 4 Speed Motor PSC ...
Страница 19: ...19 Figure 11 Wiring Diagram Variable Speed Motor ECM ...
Страница 20: ...Figure 12 Parts list with 4 speed motor PSC 20 B50091C ...
Страница 22: ...22 Figure 13 Parts list with variable speed motor ECM B50092C ...
Страница 24: ......
Страница 42: ...Figure 9 Dimensions de la fournaise 18 ...
Страница 43: ...19 Figure 10 Diagramme électrique avec moteur 4 vitesses PSC ...
Страница 44: ...20 Figure 11 Diagramme électrique avec moteur vitesse variable ECM ...
Страница 45: ...Figure 12 Liste de pièces avec moteur 4 vitesses PSC 21 B50091C 21 B50091C ...
Страница 47: ...23 B50092C 23 B50092C Figure 13 Liste de pièces avec moteur vitesse variable ECM B50092C ...