FSFXXAOA1180: Installation and User Instructions

Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.

7

WIRING

Wiring and Logic Diagrams

A200601

WARNING

!

SHOCK HAZARD

Risk  of  electric  shock.  Electrical  wiring  must  be  done  by  qualified  personnel  in  accordance  with  all  applicable  codes  and  standards.  Before

connecting wires, switch power off at service panel and lock service disconnecting means to prevent power from being switched on accidentally.

LOGIC DIAGRAM

WIRING DIAGRAM

Ref: 1103696_REV-A
VE0450A

K1

M1

Power 

Supply

(12V)

Line

Neutral

Low Voltage

(24VAC)

K2

R

C

G

Gf

PTC

AC 

Line 

Filter

J1-2

J4-7

J4-6

J4-4

J4-5

F1

High Voltage

(120VAC)

J1-1

To J10

J2-1

J2-2

Power 

Supply

(3.3V)

MCU

K1

K2

M2

Stepper

Driver

J5-1,2,3,4

 

 

WIRING COLOR CODE

BLK

BLACK

BLU

BLUE

GRN

GREEN

ORG

ORANGE

PNK

PINK

RED

RED

WHT

WHITE

YEL

YELLOW

Line voltage factory wiring
Low voltage factory wiring
Low voltage field wiring

BLK

Supply fan

motor

ORG

BLU

RED

WHT

Power cable

1

1

1

F1

J10

J2

J1

1

1

J7

J9

1

J5

BDM

1

LED 1

(low power)

LED 2

(Status)

LED 3

(120 VAC)

1

J4

1

9

M2

RED

BLU

YEL

PNK

Damper Motor 

Harness

Y

W

Gf

G

R

C

KVAAC0101DFT

 

Wall

 

Control

)

Stb-out

Stb-in

LED

+24VAC Supply

AHU Wiring

Control cable

M1

GRN

A1

ELECTRONIC ASSEMBLY

RH Sensor

Mode

n

o

Speed

120 VAC,

 

60 Hz

W1

GRN

WHT

BLK

Содержание FSFXXAOA1180

Страница 1: ...s used to highlight suggestions which will result in enhanced installation reliability or operation LIMITATION For residential domestic installation only Installation work and electrical wiring must b...

Страница 2: ...act the manufacturer 2 Before servicing or cleaning this unit disconnect power cord from electrical outlet 3 This unit is not designed to provide combustion and or dilution air for fuel burning applia...

Страница 3: ...F The in line heater shall have an integrated airflow sensor and an over temperature sensor to prevent heating in no flow or low flow conditions A200589 When deciding if a preheater is required and w...

Страница 4: ...ll Control on p8 for the wiring diagram IMPORTANT Make sure that the wire seal foam is put back in place 10 Reinstall the electronic compartment cover make sure not to pinch wires and set the Mode and...

Страница 5: ...kets on the unit as illustrated below DO NOT USE OTHER SCREWS 2 Using 4 screws no 10 12 x 0 625 in or longer screws if necessary secure the unit to the wall or ceiling into the studs joists or other s...

Страница 6: ...ated above the first floor place it close to a window or balcony to allow ease of access WARNING PERSONAL INJURY HAZARD Make sure the outdoor intake hood is at least 12 inches above the ground and 6 f...

Страница 7: ...A VE0450A K1 M1 Power Supply 12V Line Neutral Low Voltage 24VAC K2 R C G Gf PTC AC Line Filter J1 2 J4 7 J4 6 J4 4 J4 5 F1 High Voltage 120VAC J1 1 To J10 J2 1 J2 2 Power Supply 3 3V MCU K1 K2 M2 Step...

Страница 8: ...5 Remove the test port cap located on the port on the intake side of the unit closest to the filter 6 Test the airflow using a Pitot tube The distance between the test port and VD0472 the center of th...

Страница 9: ...ion standards and maintain a high standard of safety Any third party replacement part used may cause serious damage and drastically reduce the performance level of your unit which will result in prema...

Страница 10: ...ing but was in a standby period This Supply Fan is designed to provide fresh air at the best me of the day Is the unit connected to a working wall outlet Use a small electric appliance to test the out...

Страница 11: ...e damper does not move within 15 seconds replace the electronic board If the damper now works replace it Wall control error 4 blinks There is a short circuit in the wall control wiring Inspect wiring...

Страница 12: ...A A200609 VN0011A Selected mode Climatic Zones 1 Ashrae 2016 Zones 1 4 2 Ashrae 2010 factory setting Zones 1 4 3 IRC IMC 2012 2015 Zones 1 4 A Comfort mode Hot Humid 1 Zones 2A and 1 B Comfort mode Ho...

Страница 13: ...FSFXXAOA1180 Installation and User Instructions Manufacturer reserves the right to change at any time specifications and designs without notice and without obligations 13 APPENDIX B A200610...

Страница 14: ...Company Edition Date 12 20 Catalog No IM FSF 01 Replaces New FSFXXAOA1180 Installation and User Instructions Manufacturer reserves the right to change at any time specifications and designs without n...

Отзывы: