CHAIN C
(
S
EE NOTE #2)
15´-0´´ (4572 mm)
MIN. HEIGHT
ABOVE FLOOR
CHAIN
“
B
”
(
S
EE NOTE #2)
CHAIN
“
D
”
(
S
EE
NOTE #2)
“
E
”
“
F
”
“
A
”
a23-1690
*The 11th character of the chiller model number indicates the compressor type.
COMPRESSOR
TYPE*
HEAT
EXCHANGER
CODE
MAXIMUM WEIGHT
VESSEL
LENGTH
DIM.
“A”
CHAIN LENGTH
DIM.
“E”
DIM.
“F”
“B”
“C”
“D”
lb
ft
ft-in.
ft-in.
ft-in.
ft-in.
ft-in.
ft-in.
P
A1-A6
15,582
12’
6’ -7”
12
- 5
11
-6
11
- 10
3
-6
1
-6
B1-B6
16,391
14’
7
- 5
13
- 0
12
-0
12
- 4
3
-6
1
-6
Q
30-32
17,962
12
6
-10
13
- 5
13
-0
12
- 5
3
-11
3
- 8
35-37
19,501
14
7
- 8
13
-10
13
-5
12
-10
3
-11
3
- 8
40-42
21,032
12
6
-10
13
- 6
12
-8
12
- 3
4
- 1
3
-11
45-47
22,468
14
7
- 8
13
-11
13
-2
12
- 8
4
- 1
3
-11
50-52
23,856
12
6
-10
13
-10
12
-7
12
- 9
4
- 0
4
- 4
55-57
25,642
14
7
- 8
14
- 4
13
-1
13
- 1
4
- 0
4
- 4
R
30-32
19,187
12
6
-10
13
- 5
13
-0
12
- 5
3
-11
3
- 8
35-37
20,589
14
7
- 8
13
-10
13
-5
12
-10
3
-11
3
- 8
40-42
23,928
12
6
-10
13
- 6
12
-8
12
- 3
4
- 1
3
-11
45-47
25,167
14
7
- 8
13
-11
13
-2
12
- 8
4
- 1
3
-11
50-52
26,950
12
6
-10
13
-10
12
-7
12
- 9
4
- 0
4
- 4
55-57
28,479
14
7
- 8
14
- 4
13
-1
13
- 1
4
- 0
4
- 4
COMPRESSOR
TYPE*
HEAT
EXCHANGER
CODE
MAXIMUM WEIGHT
VESSEL
LENGTH
DIM.
“A”
CHAIN LENGTH
DIM.
“E”
DIM.
“F”
“B”
“C”
“D”
kg
mm
mm
mm
mm
mm
mm
mm
P
A1-A6
7 068
3658
2007
3785
3505
3607
1067
457
B1-B6
7 435
4267
2261
3962
3658
3759
1067
457
Q
30-32
8 147
3658
2083
4089
3962
3785
1194
1118
35-37
8 846
4267
2337
4216
4089
3912
1194
1118
40-42
9 540
3658
2083
4115
3861
3734
1245
1194
45-47
10 191
4267
2337
4242
4013
3861
1245
1194
50-52
10 821
3658
2083
4216
3835
3886
1219
1321
55-57
11 631
4267
2337
4369
3988
3988
1219
1321
R
30-32
8 703
3658
2083
4089
3962
3785
1194
1118
35-37
9 339
4267
2337
4216
4089
3912
1194
1118
40-42
10 854
3658
2083
4115
3861
3734
1245
1194
45-47
11 416
4267
2337
4242
4013
3861
1245
1194
50-52
12 224
3658
2083
4216
3835
3886
1219
1321
55-57
12 918
4267
2337
4369
3988
3988
1219
1321
NOTES:
1. Each chain must be capable of supporting the entire
weight of the machine. See chart for maximum
weights.
2. Chain lengths shown are typical for 15
(4572 mm)
lifting height. Some minor adjustments may be
required.
3. Units with Q and R compressors are shown on
UNITS WITH P COMPRESSOR
Fig. 13 — Machine Rigging Guide
Содержание EVERGREEN 23XRV
Страница 53: ...53 Fig 60 Typical Field Wiring Schematic LF 2 VFD Shown NOTE See Notes for Fig 60 on page 56 ...
Страница 54: ...54 Fig 60 Typical Field Wiring Schematic LF 2 VFD Shown cont a23 1585 ...
Страница 55: ...55 Fig 60 Typical Field Wiring Schematic LF 2 VFD Shown cont a23 1586 ...
Страница 60: ...60 Fig 63 23XRV Controls Schematic LF 2 ...
Страница 63: ...63 SEE NEXT PAGE SEE NEXT PAGE SEE NEXT PAGE Fig 67 23XRV Controls Schematic Rockwell Standard Tier VFD Shown ...
Страница 64: ...64 FROM PREVIOUS PAGE Fig 67 23XRV Controls Schematic Rockwell Standard Tier VFD Shown cont ...
Страница 73: ...73 Fig 78 Lead Lag Control Wiring Parallel Flow Application Unit with R Compressor Shown a23 1597 ...
Страница 74: ...74 Fig 79 Lead Lag Control Wiring Series Flow Application Unit with R Compressor Shown a23 1598 ...