REFRIGERATION HOSE AND ELECTRICAL HARNESS ROUTING - Continued:
YES
NO
____
____
Is “Mineral Oil” used to lubricate the fittings, hose and “O” Rings?
____
____
Is there a workable “service loop” at all refrigerant hose connections?
____
____
Are refrigerant hoses routed to the condenser, evaporator and compressor
properly?
____
____
I
s system free of refrigerant hose kinks and twists?
____
____
I
s excess oil wiped from fittings and hose?
Dust will collect on the oil giving the false
indication that there is a refrigerant leak.
____
____
Is 12.5 Volts available at the Compressor Clutch, Evaporator and Condenser?
____
____
Are electrical connections secure and protected from the environment?
____
____
Are electrical connections properly crimped and fastened?
____
____
Are circuit breakers located within 24 inches of the power source?
____
____
Are relays, circuit breakers and controls located in an area with adequate
ventilation?
____
____
Is the electrical panel properly grounded?
____
____
Are controls located within easy reach of the driver?
____
____
Are current (latest revision) wiring diagrams available to the installer?
SYSTEM OPERATION:
YES
NO
____
____
Does the installer clearly understand and consistently apply a method for calculating
the correct refrigerant and oil charge?
____
____
Is a Micron Gauge used during evacuation?
____
____
Was 1000 microns or less reached during evacuation?
____
____
Do evaporator blower speeds react to low, medium and high-speed settings?
____
____
Turning thermostat counterclockwise and then clockwise, does compressor turn
off and then on?
If a dual system, verify thermostat and pressure switch wiring is connected
to the proper system.
____
____
If dual system, is each system checked separately (independently of each other)?
____
____
Is freeze-up thermostat (located in evaporator) properly adjusted?
Turn
counterclockwise to end, then clockwise 1/4 turn.
Содержание DC-12175
Страница 2: ...MANUAL INSTALLATION SPLIT SYSTEMS GEN 4 5 POLICY AND PROCEDURES ...
Страница 43: ...T 311 2 20 Figure 2 47 Hose Cover Installed Left Side Figure 2 48 In Wall With Trimmed Cover Rear ...
Страница 70: ...4 12 T 311 Figure 4 22 Rear Evaporator OEM Tie in FILTER DRIER ...
Страница 71: ...4 13 T 311 Figure 4 23 Evaporator Skirt Monuted Condenser and Compressor FILTER DRIER ...
Страница 72: ...4 14 T 311 Figure 4 24 Evaporator Skirt Monuted Condenser and Compressor AC 322 332 442 FILTER DRIER ...