Using installer settings
Carrier Connect™ Wi
-Fi Thermostat 33CONNECTSTAT43FX
CARRIER CORPORATION ©2021
Installation Guide
All rights reserved
28
To reach the Installer Settings screens, set the mode to
OFF
and press and hold the
MENU
button for 5 seconds.
Scrolling though the installer settings:
•
The
HOME
button returns the installer to the home screen.
•
The
UP
and
DOWN
arrows scroll through the settings.
•
The
SELECT
button allows the installer to change the value of the setting.
•
Press
DEFAULT
to set the value to the factory default. Press
SAVE
to store the value.
•
Press
SAVE
to store the current value and return to the
SELECT
screen.
•
Press
CANCEL
to return the setting value to the last saved value and then return to the
SELECT
screen.
Setting
Default/Range
HEAT EQUIP
—
Set the type of heating equipment being used.
If you set the
COMPRESSOR
to
HP
, the heading of this screen is
EHEAT EQUIP
instead
HEAT EQUIP
.
D:
R:
GAS
GAS
ELEC (Electric Heat)
HEAT STAGES
•
If the
COMPRESSOR EQUIPMENT TYPE
is set to
HP
, the heading of this screen is
EHEAT STAGES
.
•
The option of
0
heat stages is only available if the
HEATING EQUIPMENT
is set to
electric heat (
ELEC
).
•
If set to
2
, the
W2 RELAY OUTPUT
is not available for optional functions such as
HUMIDIFIER
,
DEHUMIDIFICATION
, and
OCCUPANCY OUTPUT
D:
R:
1
0 to 2
COMPRESSOR
When set to
NONE
:
•
COOL
mode is disabled
•
DEHUMIDIFY
setting is not available
•
COOL STAGES
setting is not available
•
AUTO ALLOWED
setting is not available
When set to
HP
, the
O
output is not available for optional functions such as
HUMIDIFIER
,
DEHUMIDIFICATION
, and
OCCUPANCY OUTPUT
.
D:
R:
AC
NONE
AC
HP
Using installer settings
Содержание Connect 33CONNECTSTAT43FX
Страница 4: ......
Страница 68: ......
Страница 69: ......
Страница 70: ...Carrier 2021 Catalog No 11 808 872 01 12 3 2021 ...