4.2 - Physical data 30XA 252-902 - units with option 254 and 255**
30XA
252
302
352
402
452
502
602
702
752
802
852
902
Operating weight*
kg
3830
3860
4380
4830
4900
5470
6480
6640
7430
7750
7870
8620
Sound levels
Standard unit with options 254** or 255**
Sound power***
dB(A)
99
99
99
98
101
98
100
98
103
102
100
104
Sound pressure at 10 m
**** dB(A)
67
67
68
65
69
65
67
65
70
70
67
71
High-energy efficiency unit with option 119** and option 254** or 255**
Sound power***
dB(A)
100
100
100
100
102
100
102
100
104
104
102
105
Sound pressure at 10 m
**** dB(A)
68
68
68
68
70
68
69
68
71
71
69
72
Dimensions - standard unit + options 254/255*
Length
mm
3604
3604
4798
4798
4798
5992
7186
7186
8380
8380
8380
9574
Width
mm
2253
2253
2253
2253
2253
2253
2253
2253
2253
2253
2253
2253
Height
mm
2297
2297
2297
2297
2297
2297
2297
2297
2297
2297
2297
2297
Refrigerant*
R-134a
Circuit A
kg
60
64
70
85
85
102
102
100
129
112
130
129
teqCO
2
85.8
91.5
100.1
121.6
121.6
145.9
145.9
143.0
184.5
160.2
185.9
184.5
Circuit B
kg
64
64
56
56
56
56
88
95
88
95
95
103
teqCO
2
91.5
91.5
80.1
80.1
80.1
80.1
125.8
135.9
125.8
135.9
135.9
147.3
Compressors
06T semi-hermetic screw compressors, 50 r/s
Circuit A
1
1
1
1
1
1
1
1
1
1
1
1
Circuit B
1
1
1
1
1
1
1
1
1
1
1
1
Circuit C
-
-
-
-
-
-
-
-
-
-
-
-
Circuit D
-
-
-
-
-
-
-
-
-
-
-
-
Oil charge
Circuit A
l
20.8
20.8
20.8
23.5
23.5
23.5
23.5
23.5
27.6
27.6
27.6
27.6
Circuit B
l
20.8
20.8
20.8
20.8
20.8
20.8
23.5
23.5
23.5
23.5
23.5
27.6
Circuit C
l
-
-
-
-
-
-
-
-
-
-
-
-
Circuit D
l
-
-
-
-
-
-
-
-
-
-
-
-
Capacity control
Touch Pilot, electronic expansion valve (EXV)
Minimum capacity
%
15
15
15
15
15
15
15
15
15
15
15
15
Condensers
Copper/aluminium coil
Fans
Axial Flying Bird IV fans with rotating shroud
Quantity
6
6
7
8
8
9
11
12
13
13
14
15
Total air flow
l/s
20500
20500
20500
27333
27333
30750
37583
41000
41000
41000
47833
47833
Speed
r/s
11.7
11.7
11.7
11.7
11.7
11.7
11.7
11.7
11.7
11.7
11.7
11.7
Evaporator
Flooded multi-pipe type
Water volume
l
58
61
61
66
70
77
79
94
98
119
119
130
Maximum pressure
†
kPa
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
* Weights are guidelines only. For sizes 1402 to 1702 weight of modules 1 and 2. The refrigerant charge is given on the unit nameplate.
** Options: 119 = high energy efficiency, 254 = units with copper/aluminium coils, 255 = units with copper/aluminium coils without slots.
*** In dB ref=10
-12
W, (A) weighting. Declared dualnumber noise emission values in accordance with ISO 4871 (with an associated uncertainty of +/-3dB(A)).
Measured in accordance with ISO 9614-1 and certified by Eurovent.
**** In dB ref 20µPa, (A) weighting. Declared dualnumber noise emission values in accordance with ISO 4871 (with an associated uncertainty of +/-3dB(A)).
For information, calculated from the sound power level Lw(A).
† Max. water-side operating pressure without hydronic module.
Notes:
1. Unit sizes 30XA 1402 to 1702 are supplied in two field-assembled modules.
2. Option 119 (high energy efficiency) can be used together with options 254 and 255. Contact your Carrier representative to obtain the performances.